Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
UTL heat pump efficiency: 26 outdoor models compared
UTL has 26 heat pump outdoor models certified with this refrigerant group, in 34 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes UTL makes. UTL has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 26
- AHRI certifications
- 34
- Efficiency index
- 63%
- Typical model vs same-size, same-type peers (26 models)
- Meet CEE 2025
- 88.5%
- 23 models
How UTL compares with comparable models
- UTL
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index26 models scored | 63% | Not ranked | — |
| COP at 5°F26 models scored | 80% | Not ranked | 2.20 |
| Capacity retention at 5°F26 models scored | 59% | Not ranked | 74% |
| HSPF226 models scored | 75% | Not ranked | 9.4 |
| SEER226 models scored | 69% | Not ranked | 18.0 |
| EER226 models scored | 42% | Not ranked | 11.0 |
| Heating capacity at 5°F26 models scored | 61% | Not ranked | 25,800 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 88.5% | 23 |
| CEE 2026 Tier 1 (Split ASHP) | 88.5% | 23 |
| CEE Advanced Tier (Split ASHP) | 11.5% | 3 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 84.6% | 22 |
| DOE Cold Climate Heat Pump Challenge | 11.5% | 3 |
| ENERGY STAR Cold Climate | 100% | 26 |
Sizes and duct types offered
- UTL (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | 51% | 79% | 52% | 64% |
| Ducted, 2 tons | 6 | 73% | 76% | 75% | 72% |
| Ducted, 2.5–3 tons | 8 | 61% | 82% | 71% | 71% |
| Ducted, 3.5–4.5 tons | 11 | 60% | 81% | 80% | 67% |
Every UTL model in the market
- UTL models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top UTL models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1UCHA-24HDCTRN2UTL · TOP-DISCHARGEwith ducted air handler UCHA-24HDCALN2 | 2 tons24,000 Btu/h · Ducted | 100% | 2.30 | 10.2 | 24,000 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 218472797 | Ducted, 2 tons | 89.5 |
| 2UCHA-24HDCSN4UTL · SIDE-DISCHARGEwith ducted air handler UCHA-24HDCN4Also listed as UCHA-24HDCSN2 | 2 tons24,000 Btu/h · Ducted | 100% | 2.20 | 9.5 | 24,000 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 217739010 | Ducted, 2 tons | 80.9 |
| 3UCHA-48HDCTRN2UTL · TOP-DISCHARGEwith ducted air handler UCHA-48HDCALN2 | 4 tons48,000 Btu/h · Ducted | 79% | 2.20 | 10.5 | 38,000 | 16.5 | CEE 25CEE 26XcelES CC | 1 | 218472800 | Ducted, 3.5–4.5 tons | 79.5 |
| 4UCHA-36HDCTRN2UTL · TOP-DISCHARGEwith ducted air handler UCHA-36HDCALN2 | 3 tons34,200 Btu/h · Ducted | 75% | 2.30 | 10.0 | 25,600 | 18.0 | CEE 25CEE 26XcelES CC | 1 | 218472798 | Ducted, 2.5–3 tons | 78.1 |
| 5UCHA-48HDCSN4UTL · SIDE-DISCHARGEwith ducted air handler UCHA-48HDCN4Also listed as UCHA-48HDCSN2 | 4 tons48,000 Btu/h · Ducted | 75% | 2.25 | 9.8 | 36,000 | 17.5 | CEE 25CEE 26XcelES CC | 2 | 217739012 | Ducted, 3.5–4.5 tons | 76.6 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1UCHA-24HDCTRN2UTL · TOP-DISCHARGEwith ducted air handler UCHA-24HDCALN2 | 2 tons24,000 Btu/h · Ducted | 100% | 2.30 | 10.2 | 19.0 | 12.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 218472797 | Ducted, 2 tons | 85.0 | 89.5 | 80.6 | 89.5 |
| 2UCHA-24HDCTUTL · AHUwith ducted air handler UCHA-24HDCAlso listed as UCHA-24HDCTN2 | 2 tons24,000 Btu/h · Ducted | 74% | 2.20 | 9.5 | 20.0 | 14.0 | CEE 25CEE 26XcelES CC | 1 | 217014848 | Ducted, 2 tons | 79.3 | 65.1 | 93.4 | 65.1 |
| 3UCHA-24HDCSN4UTL · SIDE-DISCHARGEwith ducted air handler UCHA-24HDCN4Also listed as UCHA-24HDCSN2 | 2 tons24,000 Btu/h · Ducted | 100% | 2.20 | 9.5 | 18.5 | 12.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 217739010 | Ducted, 2 tons | 73.5 | 80.9 | 66.2 | 80.9 |
| 4UCHA-48HDCTUTL · AHUwith ducted air handler UCHA-48HDCAlso listed as UCHA-48HDCTN2 | 4 tons48,000 Btu/h · Ducted | 73% | 2.20 | 9.8 | 18.5 | 11.0 | CEE 25CEE 26XcelES CC | 1 | 217014849 | Ducted, 3.5–4.5 tons | 68.3 | 73.3 | 63.2 | 73.3 |
| 5UCHA-48HDCSN4UTL · SIDE-DISCHARGEwith ducted air handler UCHA-48HDCN4Also listed as UCHA-48HDCSN2 | 4 tons48,000 Btu/h · Ducted | 75% | 2.25 | 9.8 | 17.5 | 11.0 | CEE 25CEE 26XcelES CC | 2 | 217739012 | Ducted, 3.5–4.5 tons | 67.4 | 76.6 | 58.1 | 76.6 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | UCHA-36HDCTRN2 | 2.30 | Ducted, 2.5–3 tons | 89% | 218472798 |
| Capacity retention at 5°F | UCHA-24HDCSN4Also listed as UCHA-24HDCSN2 | 100% | Ducted, 2 tons | 92% | 217739010 |
| HSPF2 | UCHA-48HDCTRN2 | 10.5 | Ducted, 3.5–4.5 tons | 90% | 218472800 |
| SEER2 | UCHA-24HDCTAlso listed as UCHA-24HDCTN2 | 20.0 | Ducted, 2 tons | 87% | 217014848 |
| EER2 | UCHA-24HDCTAlso listed as UCHA-24HDCTN2 | 14.0 | Ducted, 2 tons | 98% | 217014848 |
| Heating capacity at 5°F | UCHA-24HDCSN4Also listed as UCHA-24HDCSN2 | 24,000 Btu/h | Ducted, 2 tons | 89% | 217739010 |
UTL size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 51.0(50 is the typical model of its size class)UCHA-18HFDCSN4with ducted air handler UCHA-18HFDCAN41 of 1 models qualify · AHRI 218721137 | 50.7(50 is the typical model of its size class)UCHA-18HFDCSN4with ducted air handler UCHA-18HFDCAN41 of 1 models have all five ratings · AHRI 218721137 |
| Ducted, 2 tons | 89.5(50 is the typical model of its size class)UCHA-24HDCTRN2with ducted air handler UCHA-24HDCALN26 of 6 models qualify · AHRI 218472797 | 85.0(50 is the typical model of its size class)UCHA-24HDCTRN2with ducted air handler UCHA-24HDCALN26 of 6 models have all five ratings · AHRI 218472797 |
| Ducted, 2.5–3 tons | 78.1(50 is the typical model of its size class)UCHA-36HDCTRN2with ducted air handler UCHA-36HDCALN28 of 8 models qualify · AHRI 218472798 | 65.1(50 is the typical model of its size class)UCHA-36HDCT(O)with ducted air handler UCHA-36HDCT(I)Also listed as UCHA-36HDCT, UCHA-36HDCTN28 of 8 models have all five ratings · AHRI 214771549 |
| Ducted, 3.5–4.5 tons | 79.5(50 is the typical model of its size class)UCHA-48HDCTRN2with ducted air handler UCHA-48HDCALN211 of 11 models qualify · AHRI 218472800 | 68.3(50 is the typical model of its size class)UCHA-48HDCTwith ducted air handler UCHA-48HDCAlso listed as UCHA-48HDCTN211 of 11 models have all five ratings · AHRI 217014849 |
Newest UTL certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| UCHA-60HDCTN2UTL · T* Serieswith ducted air handler UCHA-60HDCN2 | 4.5 tons54,000 Btu/h · Ducted | 2.20 | 71% | 9.0 | 17.0 | ES CC | 1 | 218775062 |
| UCHA-36HDCTN2UTL · T* Serieswith ducted air handler UCHA-36HDCN2 | 3 tons34,200 Btu/h · Ducted | 2.20 | 73% | 9.0 | 18.5 | CEE 25CEE 26XcelES CC | 1 | 218775061 |
| UCHA-48HDCTN2UTL · T* Serieswith ducted air handler UCHA-48HDCN2 | 4 tons48,000 Btu/h · Ducted | 2.20 | 73% | 9.8 | 18.5 | CEE 25CEE 26XcelES CC | 1 | 218775060 |
| UCHA-24HDCTN2UTL · T* Serieswith ducted air handler UCHA-24HDCN2 | 2 tons24,000 Btu/h · Ducted | 2.20 | 74% | 9.5 | 20.0 | CEE 25CEE 26XcelES CC | 1 | 218775059 |
| UCHA-36HFDCSN4UTL · Wall-Mount AHUwith ducted air handler UCHA-36HFDCAN4 | 3 tons36,000 Btu/h · Ducted | 2.10 | 70% | 9.0 | 16.8 | CEE 25CEE 26ES CC | 1 | 218721140 |
Compare UTL
UTL includes these brand names as listed in AHRI: UTL. Standards are checked against published thresholds; program rules beyond ratings are not checked.