Skip to content

DUOHOME heat pump efficiency: 50 outdoor models compared

DUOHOME has 50 heat pump outdoor models certified with this refrigerant group, in 85 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes DUOHOME makes. DUOHOME has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
50
AHRI certifications
85
Efficiency index
58%
Typical model vs same-size, same-type peers (58 models)
Meet CEE 2025
76%
38 models

How DUOHOME compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
DUOHOME against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of DUOHOME’s own modelsDUOHOME is strongest on HSPF2 (its typical model beats 62% of comparable models) and weakest on capacity retention at 5°F (50%).
  • DUOHOME
  • Middle half of its models
  • Other ranked manufacturers
DUOHOME

Source: AHRI Directory, NEEP · as of

Average peer percentile of DUOHOME’s models
RatingBeats comparable modelsRankRaw median
Efficiency index58 models scored58%Not ranked—
COP at 5°F58 models scored62%Not ranked2.00
Capacity retention at 5°F58 models scored50%Not ranked72%
HSPF265 models scored62%Not ranked9.4
SEER265 models scored60%Not ranked18.6
EER265 models scored51%Not ranked11.7
Heating capacity at 5°F58 models scored58%Not ranked24,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
DUOHOME’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • DUOHOME (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons772%84%71%67%
Ducted, 2 tons766%54%67%68%
Ducted, 2.5 to 3 tons1158%54%64%59%
Ducted, 3.5 to 4.5 tons1259%50%64%57%
Ducted, 5 tons and up364%75%86%84%
Non-ducted, up to 1.5 tons1155%61%60%58%
Non-ducted, 2 tons558%63%60%64%
Non-ducted, 2.5 to 3 tons448%69%55%55%
Non-ducted, 3.5 to 4.5 tons346%86%35%47%
Non-ducted, 5 tons and up227%41%18%16%

Every DUOHOME model in the market

DUOHOME’s 65 models with a known size and duct type, over the shape of the whole catalog.
DUOHOME models by size and ratingColoured: DUOHOME · grey shapes: all 15,936 models · lines: catalog medians by size
  • DUOHOME models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 65 duohome models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

DUOHOME in the cold

From NEEP’s cold-climate listings: 43 DUOHOME models against all 6,343 listed models.
DUOHOME capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°FAt 5°F a typical DUOHOME model keeps 65% of its 47°F capacity; the typical listed model keeps 69%.
  • All listed models (median, middle 50% and 80%)
  • DUOHOME (median, middle 50%)
Heating capacity, % of its 47°F maximum65%COP at maximum capacity2.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
DUOHOME: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
DUOHOME, 47°F43100%100%100%100%100%
DUOHOME, 17°F4365%67%72%79%84%
DUOHOME, 5°F4357%61%65%73%82%
DUOHOME: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
DUOHOME, 47°F432.973.143.343.553.74
DUOHOME, 17°F432.092.192.32.492.6
DUOHOME, 5°F431.851.9622.12.28

Source: NEEP ccASHP list · as of

Top DUOHOME models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 DUOHOME cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1DOX230-09HFN10-M1DUOHOMEwith ducted air handler DTJ-09HWFN10-M1-D1 ton9,000 Btu/h · Ducted83%2.3211.58,30019.7CEE 25CEE 26Xcel3218465653Ducted, up to 1.5 tons81.7
2DOX230-09HFN10-M1DUOHOMEwith ductless indoor unit DCA4-09HRFN10-M1-D1 ton9,000 Btu/h · Non-ducted83%2.1711.38,30021.6CEE 25CEE 26Xcel3218465663Non-ducted, up to 1.5 tons81.4
3DOX430-18HFN10-M1XDUOHOMEwith ductless indoor unit DSAG11D-18HRFN10-M11.5 tons18,000 Btu/h · Non-ducted100%2.0010.818,00021.7CEE 25CEE 26Xcel1217956858Non-ducted, up to 1.5 tons79.5
4D6OE30-48HFN10-M1-DDUOHOMEAlso listed as D6OE30-48HFN10-M1D-D4 tons45,000 Btu/h · Ducted81%2.1010.638,00020.4CEE 25CEE 26Xcel3217956870Ducted, 3.5 to 4.5 tons78.1
5DOX230-12HFN10-M1DUOHOMEwith ducted air handler DTJM-12HWFN10-M1-D1 ton12,000 Btu/h · Ducted74%2.4410.58,90019.5CEE 25CEE 26Xcel3218465654Ducted, up to 1.5 tons77.7

All-around best

Top 5 DUOHOME models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1D6OE30-48HFN10-M1-DDUOHOMEAlso listed as D6OE30-48HFN10-M1D-D4 tons45,000 Btu/h · Ducted81%2.1010.620.412.0CEE 25CEE 26Xcel3217956870Ducted, 3.5 to 4.5 tons85.378.192.678.1
2DOX230-09HFN10-M1DUOHOMEwith ducted air handler DTJ-09HWFN10-M1-D1 ton9,000 Btu/h · Ducted83%2.3211.519.713.0CEE 25CEE 26Xcel3218465653Ducted, up to 1.5 tons81.381.780.881.7
3DOT-D24HNR8-EA01(J0)DUOHOME · DOT-D24HNR8-EA01(J0)with ducted air handler DAH-D24HNR8-FMC(J0)2 tons24,000 Btu/h · Ducted83%2.109.420.013.3CEE 25CEE 26XcelES CC1218258583Ducted, 2 tons79.566.892.266.8
4DOX430-18HFN10-M1DUOHOMEwith ducted air handler DTJ-18HWFN10-M1-D1.5 tons17,500 Btu/h · Ducted71%2.4111.320.013.3CEE 25CEE 26Xcel3218465655Ducted, up to 1.5 tons79.270.987.470.9
5DOD30-24HFN10-M1DUOHOMEwith ducted air handler DTJ-24HWFN10-M1-D2 tons24,000 Btu/h · Ducted76%2.3011.019.012.5CEE 25CEE 26Xcel2218465656Ducted, 2 tons78.977.180.777.1

Best model on each rating

DUOHOME’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FDOX230-12HFN10-M12.47Non-ducted, up to 1.5 tons98%218465661
Capacity retention at 5°FDOX630-36HFN10-M3X105%Ducted, 2.5 to 3 tons91%218465642
HSPF2DOD30-24HFN10-M1X13.3Non-ducted, 2 tons95%217956859
SEER2D6OE30-48HFN10-M1-DAlso listed as D6OE30-48HFN10-M1D-D20.4Ducted, 3.5 to 4.5 tons96%217956870
EER2DOT-D24HNR8-EA01(J0)13.3Ducted, 2 tons93%218258583
Heating capacity at 5°FDOX630-36HFN10-M3X39,000 Btu/hDucted, 2.5 to 3 tons98%218465642

All 50 DUOHOME models in Explore

DUOHOME size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
DUOHOME: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons81.7(50 is the typical model of its size class)DOX230-09HFN10-M1with ducted air handler DTJ-09HWFN10-M1-D5 of 7 models qualify · AHRI 21846565381.3(50 is the typical model of its size class)DOX230-09HFN10-M1with ducted air handler DTJ-09HWFN10-M1-D6 of 7 models have all five ratings · AHRI 218465653
Ducted, 2 tons77.1(50 is the typical model of its size class)DOD30-24HFN10-M1with ducted air handler DTJ-24HWFN10-M1-D6 of 7 models qualify · AHRI 21846565679.5(50 is the typical model of its size class)DOT-D24HNR8-EA01(J0)with ducted air handler DAH-D24HNR8-FMC(J0)6 of 7 models have all five ratings · AHRI 218258583
Ducted, 2.5 to 3 tons73.1(50 is the typical model of its size class)DOX630-36HFN10-M3Xwith ducted air handler DVBC-36HWFN10-MC3E-D7 of 11 models qualify · AHRI 21846564270.0(50 is the typical model of its size class)D5OD30-36HFN10-M1-DAlso listed as D5OD30-36HFN10-M1D-D9 of 11 models have all five ratings · AHRI 217956867
Ducted, 3.5 to 4.5 tons78.1(50 is the typical model of its size class)D6OE30-48HFN10-M1-DAlso listed as D6OE30-48HFN10-M1D-D9 of 12 models qualify · AHRI 21795687085.3(50 is the typical model of its size class)D6OE30-48HFN10-M1-DAlso listed as D6OE30-48HFN10-M1D-D9 of 12 models have all five ratings · AHRI 217956870
Ducted, 5 tons and upNone on this board (0 of 3 models qualify)65.9(50 is the typical model of its size class)DOE30-60HFN10-M2with ducted air handler DHJ-60HWFN10-M2-D3 of 3 models have all five ratings · AHRI 218465659
Non-ducted, up to 1.5 tons81.4(50 is the typical model of its size class)DOX230-09HFN10-M1with ductless indoor unit DCA4-09HRFN10-M1-D8 of 11 models qualify · AHRI 21846566377.1(50 is the typical model of its size class)DOX230-09HFN10-M1with ductless indoor unit DCA4-09HRFN10-M1-D11 of 11 models have all five ratings · AHRI 218465663
Non-ducted, 2 tons77.6(50 is the typical model of its size class)DOD30-24HFN10-M1Xwith ductless indoor unit DSAG11D-23HRFN10-M15 of 5 models qualify · AHRI 21795685974.3(50 is the typical model of its size class)DOD30-24HFN10-M1Xwith ductless indoor unit DSAG11D-23HRFN10-M15 of 5 models have all five ratings · AHRI 217956859
Non-ducted, 2.5 to 3 tons63.6(50 is the typical model of its size class)DOD30-36HFN10-M2with ductless indoor unit DCD-36HRFN10-M2-D3 of 4 models qualify · AHRI 21846566759.3(50 is the typical model of its size class)D5OD30-36HFN10-M1-DAlso listed as D5OD30-36HFN10-M1D-D4 of 4 models have all five ratings · AHRI 217956866
Non-ducted, 3.5 to 4.5 tons60.8(50 is the typical model of its size class)D6OE30-48HFN10-M1-DAlso listed as D6OE30-48HFN10-M1D-D3 of 3 models qualify · AHRI 21795687153.1(50 is the typical model of its size class)D6OE30-48HFN10-M1-DAlso listed as D6OE30-48HFN10-M1D-D3 of 3 models have all five ratings · AHRI 217956871
Non-ducted, 5 tons and upNone on this board (0 of 2 models qualify)32.9(50 is the typical model of its size class)D6OE30-60HFN10-M1-DAlso listed as D6OE30-60HFN10-M1D-D2 of 2 models have all five ratings · AHRI 217956872

All-around board, every manufacturer

Newest DUOHOME certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified DUOHOME outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
DOE30-48HFN10-M2DUOHOMEwith ductless indoor unit DCD-48HRFN10-M2-D4 tons48,000 Btu/h · Ducted and non-ducted2.1181%9.919.0CEE 25CEE 26Xcel2218465668
DOD30-36HFN10-M2DUOHOMEwith ductless indoor unit DCD-36HRFN10-M2-D3 tons36,000 Btu/h · Ducted and non-ducted2.2070%10.320.0CEE 25Xcel2218465667
DOD30-24HFN10-M1DUOHOMEwith ductless indoor unit DCD-24HRFN10-M1-D2 tons24,000 Btu/h · Ducted and non-ducted2.3074%10.522.0CEE 25CEE 26Xcel2218465666
DOX430-18HFN10-M1DUOHOMEwith ductless indoor unit DCA4-18HRFN10-M1-D1.5 tons16,800 Btu/h · Ducted and non-ducted2.1971%11.420.7CEE 25CEE 26Xcel3218465665
DOX230-12HFN10-M1DUOHOMEwith ductless indoor unit DCA4M-12HRFN10-M1-D1 ton12,000 Btu/h · Ducted and non-ducted2.3970%10.421.1CEE 25CEE 26Xcel3218465664

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare DUOHOME

Manufacturers of a similar size, side by side.

DUOHOME includes these brand names as listed in AHRI: DUOHOME. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter