- Insights
- Manufacturers
- Nutech
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Nutech heat pump efficiency: 28 outdoor models compared
Nutech has 28 heat pump outdoor models certified with this refrigerant group, in 40 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Nutech makes. Nutech has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 28
- AHRI certifications
- 40
- Efficiency index
- 54%
- Typical model vs same-size, same-type peers (33 models)
- Meet CEE 2025
- 85.7%
- 24 models
How Nutech compares with comparable models
- Nutech
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index33 models scored | 54% | Not ranked | — |
| COP at 5°F33 models scored | 58% | Not ranked | 2.00 |
| Capacity retention at 5°F33 models scored | 42% | Not ranked | 70% |
| HSPF233 models scored | 60% | Not ranked | 9.2 |
| SEER233 models scored | 64% | Not ranked | 19.3 |
| EER233 models scored | 43% | Not ranked | 11.0 |
| Heating capacity at 5°F33 models scored | 52% | Not ranked | 19,550 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 85.7% | 24 |
| CEE 2026 Tier 1 (Split ASHP) | 78.6% | 22 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 60.7% | 17 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- Nutech (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 5 | 70% | 85% | 78% | 76% |
| Ducted, 2 tons | 3 | 65% | 56% | 77% | 77% |
| Ducted, 2.5–3 tons | 4 | 54% | 61% | 71% | 69% |
| Ducted, 3.5–4.5 tons | 6 | 57% | 38% | 73% | 71% |
| Ducted, 5 tons and up | 2 | 64% | 78% | 88% | 83% |
| Non-ducted, up to 1.5 tons | 6 | 41% | 51% | 38% | 49% |
| Non-ducted, 2 tons | 2 | 43% | 64% | 34% | 49% |
| Non-ducted, 2.5–3 tons | 3 | 42% | 51% | 36% | 56% |
| Non-ducted, 3.5–4.5 tons | 1 | 51% | 82% | 40% | 63% |
| Non-ducted, 5 tons and up | 1 | 27% | 42% | 18% | 16% |
Every Nutech model in the market
- Nutech models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Nutech models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1NOX230-09HFN10-M1Nutechwith ducted air handler NTJ-09HWFN10-M1-D | 1 ton9,000 Btu/h · Ducted | 83% | 2.32 | 11.5 | 8,300 | 19.7 | CEE 25CEE 26Xcel | 1 | 216578942 | Ducted, up to 1.5 tons | 81.3 |
| 2N6OE30-48HFN10-M1D-DNutech | 4 tons45,000 Btu/h · Ducted | 81% | 2.10 | 10.6 | 38,000 | 20.4 | CEE 25CEE 26Xcel | 3 | 215894281 | Ducted, 3.5–4.5 tons | 77.9 |
| 3NOX230-12HFN10-M1Nutechwith ducted air handler NTJ-12HWFN10-M1-D | 1 ton12,000 Btu/h · Ducted | 74% | 2.44 | 10.5 | 8,900 | 19.5 | CEE 25CEE 26Xcel | 1 | 215894265 | Ducted, up to 1.5 tons | 77.3 |
| 4NOD30-24HFN10-M1Nutechwith ducted air handler NTJ-24HWFN10-M1-D | 2 tons24,000 Btu/h · Ducted | 76% | 2.30 | 11.0 | 19,000 | 19.0 | CEE 25CEE 26Xcel | 1 | 215894267 | Ducted, 2 tons | 77.1 |
| 5N3OX430-18HFN10-M1-DNutech | 1.5 tons18,000 Btu/h · Ducted | 77% | 2.30 | 10.0 | 14,600 | 20.0 | CEE 25CEE 26Xcel | 3 | 215894272 | Ducted, up to 1.5 tons | 72.6 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1N6OE30-48HFN10-M1D-DNutech | 4 tons45,000 Btu/h · Ducted | 81% | 2.10 | 10.6 | 20.4 | 12.0 | CEE 25CEE 26Xcel | 3 | 215894281 | Ducted, 3.5–4.5 tons | 85.1 | 77.9 | 92.3 | 77.9 |
| 2NOX230-09HFN10-M1Nutechwith ducted air handler NTJ-09HWFN10-M1-D | 1 ton9,000 Btu/h · Ducted | 83% | 2.32 | 11.5 | 19.7 | 13.0 | CEE 25CEE 26Xcel | 1 | 216578942 | Ducted, up to 1.5 tons | 80.8 | 81.3 | 80.2 | 81.3 |
| 3NOD30-24HFN10-M1Nutechwith ducted air handler NTJ-24HWFN10-M1-D | 2 tons24,000 Btu/h · Ducted | 76% | 2.30 | 11.0 | 19.0 | 12.5 | CEE 25CEE 26Xcel | 1 | 215894267 | Ducted, 2 tons | 78.8 | 77.1 | 80.6 | 77.1 |
| 4NOX430-18HFN10-M1Nutechwith ducted air handler NTJ-18HWFN10-M1-D | 1.5 tons17,500 Btu/h · Ducted | 71% | 2.41 | 11.3 | 20.0 | 13.3 | CEE 25CEE 26Xcel | 1 | 215894266 | Ducted, up to 1.5 tons | 78.4 | 69.8 | 87.0 | 69.8 |
| 5N3OX430-18HFN10-M1-DNutech | 1.5 tons18,000 Btu/h · Ducted | 77% | 2.30 | 10.0 | 20.0 | 12.0 | CEE 25CEE 26Xcel | 3 | 215894272 | Ducted, up to 1.5 tons | 74.1 | 72.6 | 75.6 | 72.6 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | NOX230-12HFN10-M1 | 2.44 | Ducted, up to 1.5 tons | 95% | 215894265 |
| Capacity retention at 5°F | NWDB-48HI1N4S4-M-SE18 | 93% | Ducted, 3.5–4.5 tons | 84% | 218693827 |
| HSPF2 | NOX230-09HFN10-M1 | 11.5 | Ducted, up to 1.5 tons | 95% | 216578942 |
| SEER2 | N6OE30-48HFN10-M1D-D | 20.4 | Ducted, 3.5–4.5 tons | 96% | 215894281 |
| EER2 | NOX430-18HFN10-M1 | 13.3 | Ducted, up to 1.5 tons | 91% | 215894266 |
| Heating capacity at 5°F | N3OX430-18HFN10-M1-D | 14,000 Btu/h | Non-ducted, up to 1.5 tons | 83% | 215894273 |
Nutech size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 81.3(50 is the typical model of its size class)NOX230-09HFN10-M1with ducted air handler NTJ-09HWFN10-M1-D4 of 5 models qualify · AHRI 216578942 | 80.8(50 is the typical model of its size class)NOX230-09HFN10-M1with ducted air handler NTJ-09HWFN10-M1-D5 of 5 models have all five ratings · AHRI 216578942 |
| Ducted, 2 tons | 77.1(50 is the typical model of its size class)NOD30-24HFN10-M1with ducted air handler NTJ-24HWFN10-M1-D3 of 3 models qualify · AHRI 215894267 | 78.8(50 is the typical model of its size class)NOD30-24HFN10-M1with ducted air handler NTJ-24HWFN10-M1-D3 of 3 models have all five ratings · AHRI 215894267 |
| Ducted, 2.5–3 tons | 60.6(50 is the typical model of its size class)N5OD30-36HFN10-M1D-D2 of 4 models qualify · AHRI 215894278 | 69.5(50 is the typical model of its size class)N5OD30-36HFN10-M1D-D4 of 4 models have all five ratings · AHRI 215894278 |
| Ducted, 3.5–4.5 tons | 77.9(50 is the typical model of its size class)N6OE30-48HFN10-M1D-D6 of 6 models qualify · AHRI 215894281 | 85.1(50 is the typical model of its size class)N6OE30-48HFN10-M1D-D6 of 6 models have all five ratings · AHRI 215894281 |
| Ducted, 5 tons and up | None on this board (0 of 2 models qualify) | 65.3(50 is the typical model of its size class)NOE30-60HFN10-M2with ducted air handler NHJ-60HWFN10-M2-D2 of 2 models have all five ratings · AHRI 215894270 |
| Non-ducted, up to 1.5 tons | 65.6(50 is the typical model of its size class)N3OX430-18HFN10-M1-D3 of 6 models qualify · AHRI 215894273 | 62.1(50 is the typical model of its size class)N3OX430-18HFN10-M1-D6 of 6 models have all five ratings · AHRI 215894271 |
| Non-ducted, 2 tons | 45.1(50 is the typical model of its size class)NOX430-24HFN10-230with ductless indoor unit NSAG11D-24HRFN10-2302 of 2 models qualify · AHRI 215894262 | 56.7(50 is the typical model of its size class)N4OD30-27HFN10-M1D-D2 of 2 models have all five ratings · AHRI 215894274 |
| Non-ducted, 2.5–3 tons | 47.2(50 is the typical model of its size class)N5OD30-36HFN10-M1D-D1 of 3 models qualify · AHRI 215894277 | 58.3(50 is the typical model of its size class)N5OD30-36HFN10-M1D-D3 of 3 models have all five ratings · AHRI 215894277 |
| Non-ducted, 3.5–4.5 tons | 60.1(50 is the typical model of its size class)N6OE30-48HFN10-M1D-D1 of 1 models qualify · AHRI 215894282 | 52.8(50 is the typical model of its size class)N6OE30-48HFN10-M1D-D1 of 1 models have all five ratings · AHRI 215894282 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 32.5(50 is the typical model of its size class)N6OE30-60HFN10-M1D-D1 of 1 models have all five ratings · AHRI 215894283 |
Newest Nutech certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| NWDB-60HI1N4S4-M-SE18Nutech | 4.5 tons55,000 Btu/h · Ducted | 1.82 | 81% | 8.8 | 18.5 | CEE 25CEE 26Xcel | 1 | 218693828 |
| NWDB-48HI1N4S4-M-SE18Nutech | 4 tons48,000 Btu/h · Ducted | 1.80 | 93% | 9.0 | 19.0 | CEE 25CEE 26Xcel | 1 | 218693827 |
| NOX230-09HFN10-M1Nutechwith ducted air handler NTJ-09HWFN10-M1-D | 1 ton9,000 Btu/h · Ducted | 2.32 | 83% | 11.5 | 19.7 | CEE 25CEE 26Xcel | 1 | 216578942 |
| NOD30-36HFN10-230Nutechwith ductless indoor unit NSAG11FM-36HRFN10-230 | 3 tons36,000 Btu/h · Non-ducted | 2.02 | 67% | 9.1 | 19.5 | None | 2 | 216010704 |
| NOD30-30HFN10-230Nutechwith ductless indoor unit NSAG11F-30HRFN10-230 | 2.5 tons30,000 Btu/h · Non-ducted | 1.94 | 67% | 9.0 | 22.4 | CEE 25CEE 26 | 2 | 216010703 |
Compare Nutech
Nutech includes these brand names as listed in AHRI: Nutech. Standards are checked against published thresholds; program rules beyond ratings are not checked.