Skip to content

NG Trade vs Wells heat pumps

Measured against models of the same size and duct type, Wells scores higher on 6 of the 6 ratings. NG Trade has 36 outdoor models, Wells has 37 outdoor models. NG Trade and Wells have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
NG Trade and Wells on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Wells scores higher on 6 of the 6 ratings.
  • NG Trade
  • Wells
  • Other ranked manufacturers
NG TradeWells

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingNG TradeWells
Efficiency index55%median —64%median —
COP at 5°F63%median 2.0164%median 2.10
Capacity retention at 5°F39%median 70%62%median 75%
HSPF252%median 9.274%median 10.0
SEER258%median 20.663%median 19.4
EER246%median 11.660%median 12.0
Heating capacity at 5°F47%median 14,950 Btu/h62%median 19,000 Btu/h
Outdoor models3637
AHRI certifications49121

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardNG TradeWells
CEE 2025 Tier 1 (Split ASHP)75%27 models86.5%32 models
CEE 2026 Tier 1 (Split ASHP)72.2%26 models83.8%31 models
CEE Advanced Tier (Split ASHP)0%0 models2.7%1 models
Xcel Energy Colorado cold-climate ASHP (2025)47.2%17 models81.1%30 models
DOE Cold Climate Heat Pump Challenge0%0 models2.7%1 models
ENERGY STAR Cold Climate50%18 models83.8%31 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 10 groups where both have models
  • NG Trade
  • Wells
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,328 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeNG TradeWells
Ducted, up to 1.5 tons3 · index 60%9 · index 80%
Ducted, 2 tons2 · index 58%5 · index 73%
Ducted, 2.5 to 3 tons5 · index 63%7 · index 68%
Ducted, 3.5 to 4.5 tons3 · index 55%7 · index 64%
Ducted, 5 tons and up1 · index 63%1 · index 63%
Non-ducted, up to 1.5 tons17 · index 54%16 · index 60%
Non-ducted, 2 tons5 · index 54%4 · index 55%
Non-ducted, 2.5 to 3 tons6 · index 52%4 · index 55%
Non-ducted, 3.5 to 4.5 tons1 · index 51%3 · index 57%
Non-ducted, 5 tons and up1 · index 27%1 · index 27%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeNG TradeCold-climate score, best modelWellsCold-climate score, best model
Ducted, up to 1.5 tons73.0(50 is the typical model of its size class)MOBMH180D2 of 3 models qualify · AHRI 21659838993.7(50 is the typical model of its size class) (higher)WOS-06PRE/230with ducted air handler WIDL-06MOC/2309 of 9 models qualify · AHRI 215864077
Ducted, 2 tons59.5(50 is the typical model of its size class)EZCENO24Kwith ducted air handler EZCENI24K2 of 2 models qualify · AHRI 21676302285.8(50 is the typical model of its size class) (higher)WOS-24PRE/230with ducted air handler WIDH-24MOC/2305 of 5 models qualify · AHRI 215864084
Ducted, 2.5 to 3 tons73.7(50 is the typical model of its size class)MOSA323014 of 5 models qualify · AHRI 21750189382.7(50 is the typical model of its size class) (higher)WOM-36HH5/2307 of 7 models qualify · AHRI 215864112
Ducted, 3.5 to 4.5 tons78.1(50 is the typical model of its size class)MOBMH480D3 of 3 models qualify · AHRI 21659839882.6(50 is the typical model of its size class) (higher)WOM-48HH6/2307 of 7 models qualify · AHRI 215864115
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons86.8(50 is the typical model of its size class)OMSTAR091Ewith ductless indoor unit IMSTAR091E7 of 17 models qualify · AHRI 21673247594.9(50 is the typical model of its size class) (higher)WOS-06PRE/230with ductless indoor unit WI1C-06MOC/23011 of 16 models qualify · AHRI 215864073
Non-ducted, 2 tons65.4(50 is the typical model of its size class)OMSTAR241Ewith ductless indoor unit IMSTAR241E3 of 5 models qualify · AHRI 21673247890.1(50 is the typical model of its size class) (higher)WOS-24PRE/230with ductless indoor unit WI4C-24MOC/2304 of 4 models qualify · AHRI 215864072
Non-ducted, 2.5 to 3 tons58.3(50 is the typical model of its size class)MOSA323013 of 6 models qualify · AHRI 21802919072.8(50 is the typical model of its size class) (higher)WOM-36HH5/2304 of 4 models qualify · AHRI 215864113
Non-ducted, 3.5 to 4.5 tons60.8(50 is the typical model of its size class)MOBMH480D1 of 1 models qualify · AHRI 21659839970.3(50 is the typical model of its size class) (higher)WOM-60HH6/2303 of 3 models qualify · AHRI 215864119
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeNG TradeAll-around score, best modelWellsAll-around score, best model
Ducted, up to 1.5 tons74.7(50 is the typical model of its size class)MOBMH180D3 of 3 models have all five ratings · AHRI 21659838995.0(50 is the typical model of its size class) (higher)WOS-06PRE/230with ducted air handler WIDL-06MOC/2309 of 9 models have all five ratings · AHRI 215864077
Ducted, 2 tons64.6(50 is the typical model of its size class)MOBMH270D2 of 2 models have all five ratings · AHRI 21659839279.5(50 is the typical model of its size class) (higher)WDHP-2436T-Gwith ducted air handler WDAH-24MOC-G5 of 5 models have all five ratings · AHRI 217048501
Ducted, 2.5 to 3 tons80.8(50 is the typical model of its size class)MOSA323015 of 5 models have all five ratings · AHRI 21750189383.9(50 is the typical model of its size class) (higher)WOM-36HH5/2307 of 7 models have all five ratings · AHRI 215864112
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class)MOBMH480D3 of 3 models have all five ratings · AHRI 21659839885.3(50 is the typical model of its size class)WOM-48RH6/2307 of 7 models have all five ratings · AHRI 215864100
Ducted, 5 tons and up63.2(50 is the typical model of its size class)MOBMH600D1 of 1 models have all five ratings · AHRI 21659840163.2(50 is the typical model of its size class)WOM-60RH6/2301 of 1 models have all five ratings · AHRI 215864103
Non-ducted, up to 1.5 tons87.7(50 is the typical model of its size class)OMSTAR091Ewith ductless indoor unit IMSTAR091E14 of 17 models have all five ratings · AHRI 21673247594.5(50 is the typical model of its size class) (higher)WOS-06PRE/230with ductless indoor unit WIHW-06MOC/23016 of 16 models have all five ratings · AHRI 215864044
Non-ducted, 2 tons75.9(50 is the typical model of its size class)OMSTAR241Ewith ductless indoor unit IMSTAR241E4 of 5 models have all five ratings · AHRI 21673247875.9(50 is the typical model of its size class)WOS-24QUA/230with ductless indoor unit WIHW-24MOC/2304 of 4 models have all five ratings · AHRI 215864043
Non-ducted, 2.5 to 3 tons67.4(50 is the typical model of its size class) (higher)MOSA323015 of 6 models have all five ratings · AHRI 21802919067.0(50 is the typical model of its size class)WOM-36HH5/2304 of 4 models have all five ratings · AHRI 215864111
Non-ducted, 3.5 to 4.5 tons53.1(50 is the typical model of its size class)MOBMH480D1 of 1 models have all five ratings · AHRI 21659839962.6(50 is the typical model of its size class) (higher)WOM-60HH6/2303 of 3 models have all five ratings · AHRI 215864117
Non-ducted, 5 tons and up32.9(50 is the typical model of its size class)MOBMH600D1 of 1 models have all five ratings · AHRI 21659840032.9(50 is the typical model of its size class)WOM-60RH6/2301 of 1 models have all five ratings · AHRI 215864102

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingNG TradeWells
COP at 5°Fbeats 95% · 2.36OMSTAR121ENon-ducted, up to 1.5 tonsbeats 99% · 2.51WOS-12QUA/230Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 70% · 67%MOBMH600DDucted, 5 tons and upbeats 98% · 126%WOS-09PRE/230Non-ducted, up to 1.5 tons
HSPF2beats 96% · 13.0OMSTAR091ENon-ducted, up to 1.5 tonsbeats 99% · 11.0WOM-48HH6/230Ducted, 3.5 to 4.5 tons
SEER2beats 96% · 20.4MOBMH480DDucted, 3.5 to 4.5 tonsbeats 96% · 20.4WOM-48RH6/230Ducted, 3.5 to 4.5 tons
EER2beats 89% · 14.7OMSTAR091ENon-ducted, up to 1.5 tonsbeats 99% · 14.4WOS-06PRE/230Ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 86% · 14,500 Btu/hMOSA32181Non-ducted, up to 1.5 tonsbeats 98% · 39,000 Btu/hWDHP-36HHDucted, 2.5 to 3 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
NG Trade vs Wells: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • NG Trade (median, middle 50%)
  • Wells (median, middle 50%)
Heating capacity, % of its 47°F maximum63%69%COP at maximum capacity2.002.10

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
NG Trade: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
NG Trade, 47°F27100%100%100%100%100%
NG Trade, 17°F2766%67%71%73%78%
NG Trade, 5°F2756%59%63%66%68%
NG Trade: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
NG Trade, 47°F272.893.083.283.543.72
NG Trade, 17°F272.162.222.32.52.62
NG Trade, 5°F271.851.9722.112.31
Wells: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Wells, 47°F37100%100%100%100%100%
Wells, 17°F3765%68%74%81%84%
Wells, 5°F3756%62%69%78%83%
Wells: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Wells, 47°F372.863.13.243.593.83
Wells, 17°F372.072.232.42.522.65
Wells, 5°F371.8822.12.212.31

Source: NEEP ccASHP list · as of