Both views use the same certified data. This device remembers your choice.
Trane heat pump efficiency: 370 outdoor models compared
Trane has 370 heat pump outdoor models certified with this refrigerant group, in 93,740 AHRI-certified combinations. They are also sold as AMERICAN STANDARD, AMERISTAR, OXBOX, RUNTRU. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Trane makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 370
- AHRI certifications
- 93,740
- Efficiency index
- 50%
- Typical model vs same-size, same-type peers (268 models)
- Meet CEE 2025
- 38.6%
- 143 models
How Trane compares with comparable models
- Trane
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index268 models scored | 50% | 19th of 29 | — |
| COP at 5°F269 models scored | 69% | 1st of 29 | 2.27 |
| Capacity retention at 5°F268 models scored | 43% | 25th of 29 | 65% |
| HSPF2377 models scored | 35% | 27th of 29 | 7.5 |
| SEER2377 models scored | 40% | 26th of 29 | 15.5 |
| EER2377 models scored | 67% | 3rd of 29 | 11.7 |
| Heating capacity at 5°F268 models scored | 44% | 25th of 29 | 21,400 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 38.6% | 143 |
| CEE 2026 Tier 1 (Split ASHP) | 36.2% | 134 |
| CEE Advanced Tier (Split ASHP) | 2.4% | 9 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 25.4% | 94 |
| DOE Cold Climate Heat Pump Challenge | 2.4% | 9 |
| ENERGY STAR Cold Climate | 16.8% | 62 |
Sizes and duct types offered
- Trane (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 19 | 49% | 88% | 29% | 43% |
| Ducted, 2 tons | 40 | 42% | 75% | 29% | 26% |
| Ducted, 2.5 to 3 tons | 108 | 50% | 73% | 32% | 36% |
| Ducted, 3.5 to 4.5 tons | 133 | 53% | 72% | 35% | 43% |
| Ducted, 5 tons and up | 46 | 50% | 47% | 36% | 41% |
| Non-ducted, up to 1.5 tons | 15 | 55% | 40% | 61% | 54% |
| Non-ducted, 2 tons | 4 | 44% | 16% | 47% | 55% |
| Non-ducted, 2.5 to 3 tons | 7 | 56% | 61% | 67% | 52% |
| Non-ducted, 3.5 to 4.5 tons | 3 | 63% | 37% | 63% | 68% |
| Non-ducted, 5 tons and up | 2 | 68% | 18% | 89% | 55% |
Every Trane model in the market
- Trane models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Trane in the cold
- All listed models (median, middle 50% and 80%)
- Trane (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Trane, 47°F | 52 | 100% | 100% | 100% | 100% | 100% |
| Trane, 17°F | 52 | 71% | 73% | 85% | 90% | 93% |
| Trane, 5°F | 52 | 57% | 64% | 70% | 73% | 76% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Trane, 47°F | 52 | 2.47 | 2.92 | 3.14 | 3.66 | 4 |
| Trane, 17°F | 52 | 2.14 | 2.2 | 2.4 | 2.5 | 2.6 |
| Trane, 5°F | 52 | 1.8 | 1.96 | 2.1 | 2.2 | 2.22 |
Source: NEEP ccASHP list · as of
Top Trane models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 15TCV0X36A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TAMXD06AV41Also sold as American Standard 5A5V0X36A1 | 2.5 tons29,000 Btu/h · Ducted | 110% | 2.31 | 10.5 | 36,000 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 39 | 218868829 | Ducted, 2.5 to 3 tons | 95.1 |
| 25TWV0X48A1TRANEwith indoor coil D(A,C,E)60B4J+TDR and furnace S9V2D120U5PSC+LRP | 3.5 tons41,500 Btu/h · Ducted | 108% | 2.81 | 9.5 | 49,500 | 20.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 207 | 216794596 | Ducted, 3.5 to 4.5 tons | 92.8 |
| 35TWV0X24A1TRANEwith indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCB | 1.5 tons19,800 Btu/h · Ducted | 122% | 2.99 | 10.0 | 27,000 | 21.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 185 | 216794262 | Ducted, up to 1.5 tons | 92.7 |
| 45A6V0X24A1AMERICAN STANDARDwith indoor coil D(A,C,E)24B4J+TDR and furnace L8V1A060U3VSB+LRP | 1.5 tons19,500 Btu/h · Ducted | 98% | 2.93 | 10.0 | 21,800 | 21.0 | CEE 25CEE 26XcelES CC | 167 | 217117128 | Ducted, up to 1.5 tons | 89.4 |
| 55TCV0X61A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDRAlso sold as American Standard 5A5V0X61A1 | 4 tons48,000 Btu/h · Ducted | 100% | 2.22 | 10.0 | 55,500 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 22 | 218792281 | Ducted, 3.5 to 4.5 tons | 88.3 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 15TCV0X36A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5PX*D010AS3+P0V0D000M50SD+LRPAlso sold as American Standard 5A5V0X36A1 | 2.5 tons29,200 Btu/h · Ducted | 107% | 2.17 | 10.5 | 20.4 | 13.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 39 | 218868823 | Ducted, 2.5 to 3 tons | 95.7 | 92.8 | 98.6 | 95.1 |
| 25TWV0X48A1TRANEwith indoor coil D(A,C,E)60B4J+TDR and furnace L8V1C100U5VSB+LRP | 3.5 tons42,500 Btu/h · Ducted | 107% | 2.74 | 9.5 | 20.4 | 11.7 | CEE 25CEE 26CEE AdvXcelDOEES CC | 207 | 216794476 | Ducted, 3.5 to 4.5 tons | 89.2 | 92.4 | 86.0 | 92.8 |
| 35TWV0X36A1TRANE · 20 TruComfort Variable Speed Heat Pumpwith indoor coil 5PX*D010AS3 and furnace S8V2D120M5PDBAlso sold as American Standard 5A6V0X36A1 | 3 tons36,200 Btu/h · Ducted | 77% | 2.20 | 10.0 | 21.0 | 13.0 | CEE 25CEE 26XcelES CC | 115 | 216453109 | Ducted, 2.5 to 3 tons | 88.5 | 78.5 | 98.5 | 80.2 |
| 45A6V0X48A1AMERICAN STANDARDwith indoor coil DH60T4J and furnace S8V2D120M5PCB | 3.5 tons44,500 Btu/h · Ducted | 90% | 2.10 | 10.0 | 20.4 | 12.0 | CEE 25CEE 26XcelES CC | 230 | 217204644 | Ducted, 3.5 to 4.5 tons | 86.2 | 79.7 | 92.6 | 79.7 |
| 55TWV0X24A1TRANEwith indoor coil D(A,C,E)36C3J+TDR and furnace *UHMB060CCV3+LRP | 1.5 tons20,000 Btu/h · Ducted | 120% | 2.95 | 10.0 | 22.2 | 11.7 | CEE 25CEE 26CEE AdvXcelDOEES CC | 185 | 216794699 | Ducted, up to 1.5 tons | 85.1 | 92.4 | 77.8 | 92.7 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | 5TWR4036A1 | 3.20 | Ducted, 2.5 to 3 tons | 100% | 216952325 |
| Capacity retention at 5°F | 5A6H7036A1 | 136% | Ducted, 2.5 to 3 tons | 100% | 217155224 |
| HSPF2 | 3TXK2224AF00HAAAlso listed as 3TXK2236AF00HAA, 3TVHS036SF000AA | 13.5 | Ducted, 2.5 to 3 tons | 100% | 218451022 |
| SEER2 | 5TWV0X36A1Also sold as American Standard 5A6V0X36A1 | 21.6 | Ducted, 2.5 to 3 tons | 99% | 217734494 |
| EER2 | 5TCV0X36A1Also sold as American Standard 5A5V0X36A1 | 13.5 | Ducted, 2.5 to 3 tons | 99% | 218868823 |
| Heating capacity at 5°F | 5TWV0X24A1 | 27,200 Btu/h | Ducted, up to 1.5 tons | 100% | 216794229 |
Trane size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 92.7(50 is the typical model of its size class)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCB6 of 21 models qualify · AHRI 216794262 | 85.1(50 is the typical model of its size class)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace *UHMB060CCV3+LRP18 of 18 models have all five ratings · AHRI 216794699 |
| Ducted, 2 tons | 77.9(50 is the typical model of its size class)5A6H7024A1with ducted air handler CM24D3J+TDR13 of 38 models qualify · AHRI 217155223 | 81.5(50 is the typical model of its size class)5A6V0X24A1with indoor coil 5PX*BD06AS3 and furnace S9V2B060D3VSB+VCKIT28 of 28 models have all five ratings · AHRI 218036320 |
| Ducted, 2.5 to 3 tons | 95.1(50 is the typical model of its size class)5TCV0X36A1with ducted air handler 5TAMXD06AV41Also sold as American Standard 5A5V0X36A126 of 108 models qualify · AHRI 218868829 | 95.7(50 is the typical model of its size class)5TCV0X36A1with ducted air handler 5PX*D010AS3+P0V0D000M50SD+LRPAlso sold as American Standard 5A5V0X36A175 of 111 models have all five ratings · AHRI 218868823 |
| Ducted, 3.5 to 4.5 tons | 92.8(50 is the typical model of its size class)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace S9V2D120U5PSC+LRP39 of 133 models qualify · AHRI 216794596 | 89.2(50 is the typical model of its size class)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace L8V1C100U5VSB+LRP107 of 143 models have all five ratings · AHRI 216794476 |
| Ducted, 5 tons and up | 81.8(50 is the typical model of its size class)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA2 of 46 models qualify · AHRI 218451025 | 74.8(50 is the typical model of its size class)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA9 of 46 models have all five ratings · AHRI 218451025 |
| Non-ducted, up to 1.5 tons | 70.1(50 is the typical model of its size class)M5THM2318A12NA*15 of 15 models qualify · AHRI 218067082 | 73.9(50 is the typical model of its size class)M5THM2318A12NA*15 of 15 models have all five ratings · AHRI 218067082 |
| Non-ducted, 2 tons | 39.6(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models qualify · AHRI 215385437 | 51.4(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models have all five ratings · AHRI 215385437 |
| Non-ducted, 2.5 to 3 tons | 74.4(50 is the typical model of its size class)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA5 of 7 models qualify · AHRI 218451026 | 76.7(50 is the typical model of its size class)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA7 of 7 models have all five ratings · AHRI 218451026 |
| Non-ducted, 3.5 to 4.5 tons | 67.5(50 is the typical model of its size class)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models qualify · AHRI 218451027 | 73.8(50 is the typical model of its size class)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models have all five ratings · AHRI 218451027 |
| Non-ducted, 5 tons and up | 64.2(50 is the typical model of its size class)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models qualify · AHRI 218451028 | 68.0(50 is the typical model of its size class)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models have all five ratings · AHRI 218451028 |
Newest Trane certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| N5HP5048A1TRANEwith ducted air handler V3642B-*EC*E**1 | 3 tons37,200 Btu/h · Ducted | 1.84 | 54% | 6.8 | 12.0 | CEE 25CEE 26 | 194 | 219137224 |
| N5HP5042A1TRANEwith ducted air handler V3642B-*EC*E**1 | 3 tons33,800 Btu/h · Ducted | 1.92 | 53% | 6.8 | 12.0 | CEE 25CEE 26 | 230 | 219137222 |
| N5HP5036A1TRANEwith ducted air handler V3036B-*EC*E**1 | 2 tons26,800 Btu/h · Ducted | 1.90 | 56% | 6.8 | 12.0 | CEE 25CEE 26 | 348 | 219137219 |
| N5HP5030A1TRANEwith ducted air handler V3036B-*EC*E**1 | 2 tons23,600 Btu/h · Ducted | 1.86 | 56% | 6.8 | 12.0 | CEE 25CEE 26 | 338 | 219137213 |
| N5HP5024A1TRANEwith ducted air handler V3036B-*EC*E**1 | 1.5 tons19,500 Btu/h · Ducted | 1.78 | 54% | 6.8 | 12.0 | CEE 25CEE 26 | 422 | 219137206 |
Compare Trane