Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Innova vs Trane heat pumps
Measured against models of the same size and duct type, Trane scores higher on 4 of the 6 ratings. Innova has 332 outdoor models, Trane has 363 outdoor models. Innova has no QMID on file and is not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Innova
- Trane
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Innova | Trane |
|---|---|---|
| Efficiency index | 32%median — | 50%median — · 19th ranked |
| COP at 5°F | 22%median 1.75 | 68%median 2.24 · 1st ranked |
| Capacity retention at 5°F | 50% (higher)median 73% | 43% (higher)median 65% · 24th ranked |
| HSPF2 | 41% (higher)median 9.2 | 36% (higher)median 7.5 · 27th ranked |
| SEER2 | 22%median 15.2 | 40%median 15.5 · 25th ranked |
| EER2 | 29%median 11.0 | 66%median 11.7 · 3rd ranked |
| Heating capacity at 5°F | 22%median 6,500 Btu/h | 44%median 21,800 Btu/h · 24th ranked |
| Outdoor models | 332 | 363 |
| AHRI certifications | 332 | 84,774 |
Share of models meeting each standard
| Standard | Innova | Trane |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 38.6%140 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 36.6%133 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 2.5%9 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 31.9%106 models | 25.6%93 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 2.5%9 models |
| ENERGY STAR Cold Climate | 48.5%161 models | 17.9%65 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Innova
- Trane
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Innova | Trane |
|---|---|---|
| Ducted, up to 1.5 tons | 277 · index 34% | 18 · index 46% |
| Ducted, 2 tons | None | 42 · index 44% |
| Ducted, 2.5–3 tons | None | 102 · index 49% |
| Ducted, 3.5–4.5 tons | None | 131 · index 53% |
| Ducted, 5 tons and up | None | 46 · index 49% |
| Non-ducted, up to 1.5 tons | 55 · index 22% | 15 · index 53% |
| Non-ducted, 2 tons | None | 4 · index 42% |
| Non-ducted, 2.5–3 tons | None | 7 · index 56% |
| Non-ducted, 3.5–4.5 tons | None | 3 · index 63% |
| Non-ducted, 5 tons and up | None | 2 · index 68% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | InnovaCold-climate score, best model | TraneCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 60.8(50 is the typical model of its size class)AVK09R3H2Also listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 more246 of 277 models qualify · AHRI 218329872 | 92.5(50 is the typical model of its size class) (higher)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCB5 of 20 models qualify · AHRI 216794262 |
| Ducted, 2 tons | No models in this size class | 90.0(50 is the typical model of its size class)5TCV0X36A1with ducted air handler 5TEMCD04AV31+TDRAlso sold as American Standard 5A5V0X36A115 of 40 models qualify · AHRI 218792275 |
| Ducted, 2.5–3 tons | No models in this size class | 84.6(50 is the typical model of its size class)5TWV8X36A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2C080M5PCB24 of 102 models qualify · AHRI 216797087 |
| Ducted, 3.5–4.5 tons | No models in this size class | 93.0(50 is the typical model of its size class)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace S9V2D120U5PSC+LRP38 of 131 models qualify · AHRI 216794596 |
| Ducted, 5 tons and up | No models in this size class | 81.1(50 is the typical model of its size class)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA2 of 46 models qualify · AHRI 218451025 |
| Non-ducted, up to 1.5 tons | 32.2(50 is the typical model of its size class)AWP09R3H1Also listed as AWP09N3H1, AWP09R3H2, AWP09N3H2, AWE09R3H2 and 24 more55 of 55 models qualify · AHRI 218329994 | 68.6(50 is the typical model of its size class) (higher)M5THM2318A12NA*15 of 15 models qualify · AHRI 218067082 |
| Non-ducted, 2 tons | No models in this size class | 37.7(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models qualify · AHRI 215385437 |
| Non-ducted, 2.5–3 tons | No models in this size class | 73.8(50 is the typical model of its size class)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA5 of 7 models qualify · AHRI 218451026 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 67.2(50 is the typical model of its size class)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models qualify · AHRI 218451027 |
| Non-ducted, 5 tons and up | No models in this size class | 64.1(50 is the typical model of its size class)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models qualify · AHRI 218451028 |
All-around best
| Size and duct type | InnovaAll-around score, best model | TraneAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 54.1(50 is the typical model of its size class)AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 more277 of 277 models have all five ratings · AHRI 218329931 | 84.4(50 is the typical model of its size class) (higher)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace *UHMB060CCV3+LRP17 of 17 models have all five ratings · AHRI 216794699 |
| Ducted, 2 tons | No models in this size class | 86.7(50 is the typical model of its size class)5TCV0X36A1with ducted air handler 5TEMCD04AV31+TDRAlso sold as American Standard 5A5V0X36A131 of 31 models have all five ratings · AHRI 218792275 |
| Ducted, 2.5–3 tons | No models in this size class | 88.5(50 is the typical model of its size class)5TWV0X36A1with indoor coil 5PX*D010AS3 and furnace S8V2D120M5PDBAlso sold as American Standard 5A6V0X36A171 of 107 models have all five ratings · AHRI 216453109 |
| Ducted, 3.5–4.5 tons | No models in this size class | 88.9(50 is the typical model of its size class)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace L8V1C100U5VSB+LRP102 of 138 models have all five ratings · AHRI 216794476 |
| Ducted, 5 tons and up | No models in this size class | 74.7(50 is the typical model of its size class)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA9 of 46 models have all five ratings · AHRI 218451025 |
| Non-ducted, up to 1.5 tons | 23.2(50 is the typical model of its size class)APP10*3*1Also listed as APP10*3*2, APK10*3*2, APP10N4H1, APP10N3H1 and 9 more55 of 55 models have all five ratings · AHRI 218329814 | 72.2(50 is the typical model of its size class) (higher)M5THM2318A12NA*15 of 15 models have all five ratings · AHRI 218067082 |
| Non-ducted, 2 tons | No models in this size class | 48.8(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models have all five ratings · AHRI 215385437 |
| Non-ducted, 2.5–3 tons | No models in this size class | 76.2(50 is the typical model of its size class)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA7 of 7 models have all five ratings · AHRI 218451026 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 73.9(50 is the typical model of its size class)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models have all five ratings · AHRI 218451027 |
| Non-ducted, 5 tons and up | No models in this size class | 67.9(50 is the typical model of its size class)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models have all five ratings · AHRI 218451028 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Innova | Trane |
|---|---|---|
| COP at 5°F | beats 69% · 2.01AVP20R3H1-2Also listed as AVP20R4H1, AVP20N4H1, AVP20R3H1, AVP20N3H1 and 18 moreDucted, up to 1.5 tons | beats 100% · 3.205TWR4036A1Ducted, 2.5–3 tons |
| Capacity retention at 5°F | beats 86% · 95%AVK09R3H2Also listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 moreDucted, up to 1.5 tons | beats 100% · 136%5A6H7036A1Ducted, 2.5–3 tons |
| HSPF2 | beats 68% · 9.9AVP10*3*1Also listed as AVP10*3*2, AVE10*3*2, AVK10*3*2, AXP10*3*1 and 35 moreDucted, up to 1.5 tons | beats 100% · 13.53TXK2224AF00HAAAlso listed as 3TXK2236AF00HAA, 3TVHS036SF000AADucted, 2.5–3 tons |
| SEER2 | beats 44% · 15.4AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons | beats 99% · 21.65TWV0X36A1Also sold as American Standard 5A6V0X36A1Ducted, 2.5–3 tons |
| EER2 | beats 53% · 11.7AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons | beats 99% · 14.43TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAANon-ducted, 2.5–3 tons |
| Heating capacity at 5°F | beats 68% · 12,000 Btu/hAVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons | beats 100% · 27,200 Btu/h5TWV0X24A1Ducted, up to 1.5 tons |