Both views use the same certified data. This device remembers your choice.
Daikin vs Innova heat pumps
Measured against models of the same size and duct type, Daikin scores higher on 4 of the 6 ratings. Daikin has 410 outdoor models, Innova has 382 outdoor models. Innova has no QMID on file and is not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Daikin
- Innova
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Daikin | Innova |
|---|---|---|
| Efficiency index | 51% (higher)median — · 18th ranked | 32% (higher)median — |
| COP at 5°F | 48% (higher)median 2.00 · 20th ranked | 22% (higher)median 1.75 |
| Capacity retention at 5°F | 49%median 68% · 18th ranked | 51%median 73% |
| HSPF2 | 38%median 7.9 · 26th ranked | 41%median 9.2 |
| SEER2 | 46% (higher)median 16.6 · 20th ranked | 22% (higher)median 15.2 |
| EER2 | 55% (higher)median 11.7 · 13th ranked | 30% (higher)median 11.0 |
| Heating capacity at 5°F | 47% (higher)median 23,000 Btu/h · 20th ranked | 21% (higher)median 6,500 Btu/h |
| Outdoor models | 410 | 382 |
| AHRI certifications | 21,489 | 382 |
Share of models meeting each standard
| Standard | Daikin | Innova |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 39.5%162 models | 0%0 models |
| CEE 2026 Tier 1 (Split ASHP) | 35.4%145 models | 0%0 models |
| CEE Advanced Tier (Split ASHP) | 2.2%9 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 30.5%125 models | 31.4%120 models |
| DOE Cold Climate Heat Pump Challenge | 2.2%9 models | 0%0 models |
| ENERGY STAR Cold Climate | 17.6%72 models | 48.7%186 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Daikin
- Innova
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Daikin | Innova |
|---|---|---|
| Ducted, up to 1.5 tons | 35 · index 41% | 316 · index 34% |
| Ducted, 2 tons | 49 · index 44% | None |
| Ducted, 2.5 to 3 tons | 109 · index 52% | None |
| Ducted, 3.5 to 4.5 tons | 153 · index 57% | None |
| Ducted, 5 tons and up | 16 · index 49% | None |
| Non-ducted, up to 1.5 tons | 46 · index 50% | 66 · index 23% |
| Non-ducted, 2 tons | 13 · index 51% | None |
| Non-ducted, 2.5 to 3 tons | 11 · index 49% | None |
| Non-ducted, 3.5 to 4.5 tons | 7 · index 33% | None |
| Non-ducted, 5 tons and up | 1 · index 49% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | DaikinCold-climate score, best model | InnovaCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.6(50 is the typical model of its size class) (higher)MST183G32MHAA16 of 35 models qualify · AHRI 218083367 | 61.5(50 is the typical model of its size class)AVK09R3H2Also listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 more270 of 316 models qualify · AHRI 218329872 |
| Ducted, 2 tons | 89.2(50 is the typical model of its size class)DH9VSA241CA*with ducted air handler CAHEA3630C3A*+MBVK16CH*X00AAlso sold as Amana AZV9SA241CA, Goodman GZV9SA241CA12 of 49 models qualify · AHRI 216699791 | No models in this size class |
| Ducted, 2.5 to 3 tons | 90.3(50 is the typical model of its size class)MST273G32MHAA37 of 109 models qualify · AHRI 218083370 | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 72.4(50 is the typical model of its size class)GLZS4BA6010A*with ducted air handler M60G55*+TXV+AMHE5D50 of 153 models qualify · AHRI 218159995 | No models in this size class |
| Ducted, 5 tons and up | 77.6(50 is the typical model of its size class)RXTA60AAVJU*1 of 16 models qualify · AHRI 217178417 | No models in this size class |
| Non-ducted, up to 1.5 tons | 84.6(50 is the typical model of its size class) (higher)MST183G32MHAA37 of 46 models qualify · AHRI 218083366 | 33.6(50 is the typical model of its size class)AWP09R3H1Also listed as AWP09N3H1, AWP09R3H2, AWP09N3H2, AWE09R3H2 and 35 more66 of 66 models qualify · AHRI 218329994 |
| Non-ducted, 2 tons | 77.5(50 is the typical model of its size class)RXTA24AAVJU*10 of 13 models qualify · AHRI 217178408 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 83.8(50 is the typical model of its size class)MST273G32MHAA9 of 11 models qualify · AHRI 218083371 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 47.4(50 is the typical model of its size class)RXLA48AAVJU*7 of 7 models qualify · AHRI 217178413 | No models in this size class |
| Non-ducted, 5 tons and up | 71.2(50 is the typical model of its size class)RXTA60AAVJU*1 of 1 models qualify · AHRI 217178411 | No models in this size class |
All-around best
| Size and duct type | DaikinAll-around score, best model | InnovaAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 92.5(50 is the typical model of its size class) (higher)MST183G32MHAA33 of 33 models have all five ratings · AHRI 218083367 | 55.4(50 is the typical model of its size class)AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 more316 of 316 models have all five ratings · AHRI 218329931 |
| Ducted, 2 tons | 88.2(50 is the typical model of its size class)DH9VSA241CA*with ducted air handler CAHEA3630C3A*+MBVK16CH*X00AAlso sold as Amana AZV9SA241CA, Goodman GZV9SA241CA31 of 43 models have all five ratings · AHRI 216699791 | No models in this size class |
| Ducted, 2.5 to 3 tons | 91.8(50 is the typical model of its size class)MST273G32MHAA83 of 112 models have all five ratings · AHRI 218083370 | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 79.1(50 is the typical model of its size class)DPSH04BAPB2****E35**0*Also listed as DPSH04BAPB3****E35**0, DPSH04BAPB4****E35**0, DPSH04BAPB5****E35**0120 of 153 models have all five ratings · AHRI 216030296 | No models in this size class |
| Ducted, 5 tons and up | 63.0(50 is the typical model of its size class)GLZT7CA6010A*with ducted air handler AMVT60DP1300A20 of 21 models have all five ratings · AHRI 216369259 | No models in this size class |
| Non-ducted, up to 1.5 tons | 90.5(50 is the typical model of its size class) (higher)MST183G32MHAA46 of 46 models have all five ratings · AHRI 218083366 | 23.7(50 is the typical model of its size class)APP10*3*1Also listed as APP10*3*2, APK10*3*2, APP10N4H1, APP10N3H1 and 9 more66 of 66 models have all five ratings · AHRI 218329814 |
| Non-ducted, 2 tons | 86.1(50 is the typical model of its size class)RXTA24AAVJU*13 of 13 models have all five ratings · AHRI 217178408 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 89.4(50 is the typical model of its size class)MST273G32MHAA11 of 11 models have all five ratings · AHRI 218083369 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 48.1(50 is the typical model of its size class)RXLA48AAVJU*7 of 7 models have all five ratings · AHRI 217178413 | No models in this size class |
| Non-ducted, 5 tons and up | 48.7(50 is the typical model of its size class)RXTA60AAVJU*1 of 1 models have all five ratings · AHRI 217178411 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Daikin | Innova |
|---|---|---|
| COP at 5°F | beats 100% · 2.50RXTA36AAVJU*Non-ducted, 2.5 to 3 tons | beats 70% · 2.01AVP20R3H1-2Also listed as AVP20R4H1, AVP20N4H1, AVP20R3H1, AVP20N3H1 and 18 moreDucted, up to 1.5 tons |
| Capacity retention at 5°F | beats 99% · 109%RZA30AAVJU*Non-ducted, 2.5 to 3 tons | beats 86% · 95%AVK09R3H2Also listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 moreDucted, up to 1.5 tons |
| HSPF2 | beats 96% · 10.5MST273G32MHAADucted, 2.5 to 3 tons | beats 69% · 9.9AVP10*3*1Also listed as AVP10*3*2, AVE10*3*2, AVK10*3*2, AXP10*3*1 and 35 moreDucted, up to 1.5 tons |
| SEER2 | beats 98% · 21.0DH9VSA361CA*Also sold as Amana AZV9SA361CA, Goodman GZV9SA361CADucted, 2.5 to 3 tons | beats 45% · 15.4AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons |
| EER2 | beats 100% · 14.5MST183G32MHAADucted, up to 1.5 tons | beats 55% · 11.7AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons |
| Heating capacity at 5°F | beats 99% · 21,600 Btu/hRXM18WVJU*Non-ducted, up to 1.5 tons | beats 68% · 12,000 Btu/hAVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Daikin (median, middle 50%)
- Innova (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Daikin, 47°F | 135 | 100% | 100% | 100% | 100% | 100% |
| Daikin, 17°F | 135 | 67% | 72% | 80% | 90% | 101% |
| Daikin, 5°F | 135 | 53% | 60% | 70% | 75% | 87% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Daikin, 47°F | 135 | 2.92 | 3.17 | 3.3 | 3.58 | 3.92 |
| Daikin, 17°F | 135 | 2.09 | 2.24 | 2.3 | 2.55 | 2.74 |
| Daikin, 5°F | 135 | 1.8 | 1.8 | 2 | 2.1 | 2.23 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Innova, 47°F | 174 | 100% | 100% | 100% | 100% | 100% |
| Innova, 17°F | 174 | 60% | 60% | 65% | 69% | 73% |
| Innova, 5°F | 174 | 48% | 56% | 57% | 58% | 67% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Innova, 47°F | 174 | 2.75 | 2.84 | 2.84 | 3.46 | 3.47 |
| Innova, 17°F | 174 | 1.91 | 2.02 | 2.02 | 2.32 | 2.33 |
| Innova, 5°F | 174 | 1.75 | 1.75 | 1.75 | 1.75 | 1.95 |
Source: NEEP ccASHP list · as of