Daikin heat pump efficiency: 410 outdoor models compared
Daikin has 410 heat pump outdoor models certified with this refrigerant group, in 21,489 AHRI-certified combinations. They are also sold as AMANA, AMANA DISTINCTIONS, GOODMAN. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Daikin makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 410
- AHRI certifications
- 21,489
- Efficiency index
- 51%
- Typical model vs same-size, same-type peers (365 models)
- Meet CEE 2025
- 39.5%
- 162 models
How Daikin compares with comparable models
- Daikin
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index365 models scored | 51% | 18th of 29 | — |
| COP at 5°F365 models scored | 48% | 20th of 29 | 2.00 |
| Capacity retention at 5°F365 models scored | 49% | 18th of 29 | 68% |
| HSPF2440 models scored | 38% | 26th of 29 | 7.9 |
| SEER2440 models scored | 46% | 20th of 29 | 16.6 |
| EER2440 models scored | 55% | 13th of 29 | 11.7 |
| Heating capacity at 5°F365 models scored | 47% | 20th of 29 | 23,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 39.5% | 162 |
| CEE 2026 Tier 1 (Split ASHP) | 35.4% | 145 |
| CEE Advanced Tier (Split ASHP) | 2.2% | 9 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 30.5% | 125 |
| DOE Cold Climate Heat Pump Challenge | 2.2% | 9 |
| ENERGY STAR Cold Climate | 17.6% | 72 |
Sizes and duct types offered
- Daikin (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 35 | 41% | 54% | 23% | 38% |
| Ducted, 2 tons | 49 | 44% | 65% | 28% | 32% |
| Ducted, 2.5 to 3 tons | 109 | 52% | 47% | 34% | 44% |
| Ducted, 3.5 to 4.5 tons | 153 | 57% | 45% | 42% | 55% |
| Ducted, 5 tons and up | 16 | 49% | 39% | 43% | 51% |
| Non-ducted, up to 1.5 tons | 46 | 50% | 47% | 56% | 41% |
| Non-ducted, 2 tons | 13 | 51% | 41% | 47% | 45% |
| Non-ducted, 2.5 to 3 tons | 11 | 49% | 39% | 42% | 44% |
| Non-ducted, 3.5 to 4.5 tons | 7 | 33% | 40% | 21% | 23% |
| Non-ducted, 5 tons and up | 1 | 49% | 99% | 48% | 52% |
Every Daikin model in the market
- Daikin models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Daikin in the cold
- All listed models (median, middle 50% and 80%)
- Daikin (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Daikin, 47°F | 135 | 100% | 100% | 100% | 100% | 100% |
| Daikin, 17°F | 135 | 67% | 72% | 80% | 90% | 101% |
| Daikin, 5°F | 135 | 53% | 60% | 70% | 75% | 87% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Daikin, 47°F | 135 | 2.92 | 3.17 | 3.3 | 3.58 | 3.92 |
| Daikin, 17°F | 135 | 2.09 | 2.24 | 2.3 | 2.55 | 2.74 |
| Daikin, 5°F | 135 | 1.8 | 1.8 | 2 | 2.1 | 2.23 |
Source: NEEP ccASHP list · as of
Top Daikin models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MST273G32MHAAGOODMAN · MST Series | 2.5 tons28,000 Btu/h · Ducted | 100% | 2.20 | 10.5 | 28,000 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 218083370 | Ducted, 2.5 to 3 tons | 90.3 |
| 2DH9VSA241CA*DAIKIN · DH9VSAwith ducted air handler CAHEA3630C3A*+MBVK16CH*X00AAlso sold as Amana AZV9SA241CA, Goodman GZV9SA241CA | 2 tons24,000 Btu/h · Ducted | 100% | 2.40 | 10.0 | 24,000 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 47 | 216699791 | Ducted, 2 tons | 89.2 |
| 3DH9VSA361CA*DAIKIN · DH9VSAwith ducted air handler CAHEA3630C3A*+MBVK16CH*X00AAlso sold as Amana AZV9SA361CA, Goodman GZV9SA361CA | 3 tons34,200 Btu/h · Ducted | 100% | 2.40 | 10.0 | 34,200 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 35 | 216699792 | Ducted, 2.5 to 3 tons | 88.5 |
| 4MST183G32MHAAGOODMAN · MST Series | 1.5 tons19,000 Btu/h · Ducted | 103% | 2.08 | 11.0 | 20,600 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 218083367 | Ducted, up to 1.5 tons | 86.6 |
| 5MST183G32MHAAGOODMAN · MST Series | 1.5 tons19,000 Btu/h · Non-ducted | 100% | 2.10 | 11.0 | 20,000 | 27.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 218083366 | Non-ducted, up to 1.5 tons | 84.6 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MST183G32MHAAGOODMAN · MST Series | 1.5 tons19,000 Btu/h · Ducted | 103% | 2.08 | 11.0 | 22.0 | 14.5 | CEE 25CEE 26XcelES CC | 3 | 218083367 | Ducted, up to 1.5 tons | 92.5 | 86.6 | 98.4 | 86.6 |
| 2MST273G32MHAAGOODMAN · MST Series | 2.5 tons28,000 Btu/h · Ducted | 100% | 2.20 | 10.5 | 20.0 | 12.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 218083370 | Ducted, 2.5 to 3 tons | 91.8 | 90.3 | 93.3 | 90.3 |
| 3MST183G32MHAAGOODMAN · MST Series | 1.5 tons19,000 Btu/h · Non-ducted | 100% | 2.10 | 11.0 | 27.0 | 16.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 218083366 | Non-ducted, up to 1.5 tons | 90.5 | 84.6 | 96.5 | 84.6 |
| 4MST273G32MHAAGOODMAN · MST Series | 2.5 tons28,000 Btu/h · Non-ducted | 99% | 2.20 | 10.5 | 24.0 | 14.5 | CEE 25CEE 26XcelES CC | 3 | 218083369 | Non-ducted, 2.5 to 3 tons | 89.4 | 83.8 | 94.9 | 83.8 |
| 5DH9VSA361CA*DAIKIN · DH9VSAwith ducted air handler CAHEA3630C3A*+MBVK16CH*X00AAlso sold as Amana AZV9SA361CA, Goodman GZV9SA361CA | 3 tons34,200 Btu/h · Ducted | 100% | 2.40 | 10.0 | 21.0 | 12.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 35 | 216699792 | Ducted, 2.5 to 3 tons | 89.3 | 88.5 | 90.0 | 88.5 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | RXTA36AAVJU* | 2.50 | Non-ducted, 2.5 to 3 tons | 100% | 217178409 |
| Capacity retention at 5°F | RZA30AAVJU* | 109% | Non-ducted, 2.5 to 3 tons | 99% | 217175210 |
| HSPF2 | MST273G32MHAA | 10.5 | Ducted, 2.5 to 3 tons | 96% | 218083370 |
| SEER2 | DH9VSA361CA*Also sold as Amana AZV9SA361CA, Goodman GZV9SA361CA | 21.0 | Ducted, 2.5 to 3 tons | 98% | 216699792 |
| EER2 | MST183G32MHAA | 14.5 | Ducted, up to 1.5 tons | 100% | 218083367 |
| Heating capacity at 5°F | RXM18WVJU* | 21,600 Btu/h | Non-ducted, up to 1.5 tons | 99% | 212494259 |
Daikin size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.6(50 is the typical model of its size class)MST183G32MHAA16 of 35 models qualify · AHRI 218083367 | 92.5(50 is the typical model of its size class)MST183G32MHAA33 of 33 models have all five ratings · AHRI 218083367 |
| Ducted, 2 tons | 89.2(50 is the typical model of its size class)DH9VSA241CA*with ducted air handler CAHEA3630C3A*+MBVK16CH*X00AAlso sold as Amana AZV9SA241CA, Goodman GZV9SA241CA12 of 49 models qualify · AHRI 216699791 | 88.2(50 is the typical model of its size class)DH9VSA241CA*with ducted air handler CAHEA3630C3A*+MBVK16CH*X00AAlso sold as Amana AZV9SA241CA, Goodman GZV9SA241CA31 of 43 models have all five ratings · AHRI 216699791 |
| Ducted, 2.5 to 3 tons | 90.3(50 is the typical model of its size class)MST273G32MHAA37 of 109 models qualify · AHRI 218083370 | 91.8(50 is the typical model of its size class)MST273G32MHAA83 of 112 models have all five ratings · AHRI 218083370 |
| Ducted, 3.5 to 4.5 tons | 72.4(50 is the typical model of its size class)GLZS4BA6010A*with ducted air handler M60G55*+TXV+AMHE5D50 of 153 models qualify · AHRI 218159995 | 79.1(50 is the typical model of its size class)DPSH04BAPB2****E35**0*Also listed as DPSH04BAPB3****E35**0, DPSH04BAPB4****E35**0, DPSH04BAPB5****E35**0120 of 153 models have all five ratings · AHRI 216030296 |
| Ducted, 5 tons and up | 77.6(50 is the typical model of its size class)RXTA60AAVJU*1 of 16 models qualify · AHRI 217178417 | 63.0(50 is the typical model of its size class)GLZT7CA6010A*with ducted air handler AMVT60DP1300A20 of 21 models have all five ratings · AHRI 216369259 |
| Non-ducted, up to 1.5 tons | 84.6(50 is the typical model of its size class)MST183G32MHAA37 of 46 models qualify · AHRI 218083366 | 90.5(50 is the typical model of its size class)MST183G32MHAA46 of 46 models have all five ratings · AHRI 218083366 |
| Non-ducted, 2 tons | 77.5(50 is the typical model of its size class)RXTA24AAVJU*10 of 13 models qualify · AHRI 217178408 | 86.1(50 is the typical model of its size class)RXTA24AAVJU*13 of 13 models have all five ratings · AHRI 217178408 |
| Non-ducted, 2.5 to 3 tons | 83.8(50 is the typical model of its size class)MST273G32MHAA9 of 11 models qualify · AHRI 218083371 | 89.4(50 is the typical model of its size class)MST273G32MHAA11 of 11 models have all five ratings · AHRI 218083369 |
| Non-ducted, 3.5 to 4.5 tons | 47.4(50 is the typical model of its size class)RXLA48AAVJU*7 of 7 models qualify · AHRI 217178413 | 48.1(50 is the typical model of its size class)RXLA48AAVJU*7 of 7 models have all five ratings · AHRI 217178413 |
| Non-ducted, 5 tons and up | 71.2(50 is the typical model of its size class)RXTA60AAVJU*1 of 1 models qualify · AHRI 217178411 | 48.7(50 is the typical model of its size class)RXTA60AAVJU*1 of 1 models have all five ratings · AHRI 217178411 |
Newest Daikin certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| RXV18AVJU*DAIKINwith ductless indoor unit FTXJ18AVJUB | 1.5 tons18,000 Btu/h · Non-ducted | 2.00 | 93% | 8.5 | 18.0 | CEE 25CEE 26Xcel | 4 | 219136873 |
| RXV12AVJU*DAIKINwith ductless indoor unit FTXJ12AVJUB | 1 ton12,000 Btu/h · Non-ducted | 2.00 | 79% | 8.5 | 20.0 | CEE 25CEE 26Xcel | 4 | 219136870 |
| RXV09AVJU*DAIKINwith ductless indoor unit FTXJ09AVJUB | 1 ton9,000 Btu/h · Non-ducted | 2.20 | 81% | 9.0 | 20.0 | CEE 25CEE 26Xcel | 4 | 219136867 |
| GLZS5BA2410A*GOODMANwith ducted air handler FE*E31*24+TXV | 2 tons22,800 Btu/h · Ducted | 1.84 | 51% | 7.6 | 15.2 | None | 739 | 218869108 |
| GLZS4MA2410A*GOODMANwith ducted air handler FE*E31*24+TXV | 2 tons23,400 Btu/h · Ducted | 1.76 | 52% | 7.6 | 16.0 | None | 581 | 218869107 |
Compare Daikin
Daikin includes these brand names as listed in AHRI: AMANA, AMANA DISTINCTIONS, DAIKIN, GOODMAN. Standards are checked against published thresholds; program rules beyond ratings are not checked.