Skip to content

Daikin vs Ephoca heat pumps

Measured against models of the same size and duct type, Daikin scores higher on 4 of the 6 ratings. Daikin has 410 outdoor models, Ephoca has 382 outdoor models. Ephoca has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Daikin and Ephoca on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Daikin scores higher on 4 of the 6 ratings.
  • Daikin
  • Ephoca
  • Other ranked manufacturers
DaikinEphoca

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingDaikinEphoca
Efficiency index51% (higher)median — · 18th ranked32% (higher)median —
COP at 5°F48% (higher)median 2.00 · 20th ranked22% (higher)median 1.75
Capacity retention at 5°F49%median 68% · 18th ranked51%median 73%
HSPF238%median 7.9 · 26th ranked41%median 9.2
SEER246% (higher)median 16.6 · 20th ranked22% (higher)median 15.2
EER255% (higher)median 11.7 · 13th ranked30% (higher)median 11.0
Heating capacity at 5°F47% (higher)median 23,000 Btu/h · 20th ranked21% (higher)median 6,500 Btu/h
Outdoor models410382
AHRI certifications21,489382

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardDaikinEphoca
CEE 2025 Tier 1 (Split ASHP)39.5%162 models0%0 models
CEE 2026 Tier 1 (Split ASHP)35.4%145 models0%0 models
CEE Advanced Tier (Split ASHP)2.2%9 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)30.5%125 models31.4%120 models
DOE Cold Climate Heat Pump Challenge2.2%9 models0%0 models
ENERGY STAR Cold Climate17.6%72 models48.7%186 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 2 groups where both have models
  • Daikin
  • Ephoca
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeDaikinEphoca
Ducted, up to 1.5 tons35 · index 41%316 · index 34%
Ducted, 2 tons49 · index 44%None
Ducted, 2.5 to 3 tons109 · index 52%None
Ducted, 3.5 to 4.5 tons153 · index 57%None
Ducted, 5 tons and up16 · index 49%None
Non-ducted, up to 1.5 tons46 · index 50%66 · index 23%
Non-ducted, 2 tons13 · index 51%None
Non-ducted, 2.5 to 3 tons11 · index 49%None
Non-ducted, 3.5 to 4.5 tons7 · index 33%None
Non-ducted, 5 tons and up1 · index 49%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeDaikinCold-climate score, best modelEphocaCold-climate score, best model
Ducted, up to 1.5 tons86.6(50 is the typical model of its size class) (higher)MST183G32MHAA16 of 35 models qualify · AHRI 21808336761.5(50 is the typical model of its size class)AVK09R3H2Also listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 more270 of 316 models qualify · AHRI 217607099
Ducted, 2 tons89.2(50 is the typical model of its size class)DH9VSA241CA*with ducted air handler CAHEA3630C3A*+MBVK16CH*X00AAlso sold as Amana AZV9SA241CA, Goodman GZV9SA241CA12 of 49 models qualify · AHRI 216699791No models in this size class
Ducted, 2.5 to 3 tons90.3(50 is the typical model of its size class)MST273G32MHAA37 of 109 models qualify · AHRI 218083370No models in this size class
Ducted, 3.5 to 4.5 tons72.4(50 is the typical model of its size class)GLZS4BA6010A*with ducted air handler M60G55*+TXV+AMHE5D50 of 153 models qualify · AHRI 218159995No models in this size class
Ducted, 5 tons and up77.6(50 is the typical model of its size class)RXTA60AAVJU*1 of 16 models qualify · AHRI 217178417No models in this size class
Non-ducted, up to 1.5 tons84.6(50 is the typical model of its size class) (higher)MST183G32MHAA37 of 46 models qualify · AHRI 21808336633.6(50 is the typical model of its size class)AWP09R3H1Also listed as AWP09N3H1, AWP09R3H2, AWP09N3H2, AWE09R3H2 and 35 more66 of 66 models qualify · AHRI 217677964
Non-ducted, 2 tons77.5(50 is the typical model of its size class)RXTA24AAVJU*10 of 13 models qualify · AHRI 217178408No models in this size class
Non-ducted, 2.5 to 3 tons83.8(50 is the typical model of its size class)MST273G32MHAA9 of 11 models qualify · AHRI 218083371No models in this size class
Non-ducted, 3.5 to 4.5 tons47.4(50 is the typical model of its size class)RXLA48AAVJU*7 of 7 models qualify · AHRI 217178413No models in this size class
Non-ducted, 5 tons and up71.2(50 is the typical model of its size class)RXTA60AAVJU*1 of 1 models qualify · AHRI 217178411No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeDaikinAll-around score, best modelEphocaAll-around score, best model
Ducted, up to 1.5 tons92.5(50 is the typical model of its size class) (higher)MST183G32MHAA33 of 33 models have all five ratings · AHRI 21808336755.4(50 is the typical model of its size class)AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 more316 of 316 models have all five ratings · AHRI 217650520
Ducted, 2 tons88.2(50 is the typical model of its size class)DH9VSA241CA*with ducted air handler CAHEA3630C3A*+MBVK16CH*X00AAlso sold as Amana AZV9SA241CA, Goodman GZV9SA241CA31 of 43 models have all five ratings · AHRI 216699791No models in this size class
Ducted, 2.5 to 3 tons91.8(50 is the typical model of its size class)MST273G32MHAA83 of 112 models have all five ratings · AHRI 218083370No models in this size class
Ducted, 3.5 to 4.5 tons79.1(50 is the typical model of its size class)DPSH04BAPB2****E35**0*Also listed as DPSH04BAPB3****E35**0, DPSH04BAPB4****E35**0, DPSH04BAPB5****E35**0120 of 153 models have all five ratings · AHRI 216030296No models in this size class
Ducted, 5 tons and up63.0(50 is the typical model of its size class)GLZT7CA6010A*with ducted air handler AMVT60DP1300A20 of 21 models have all five ratings · AHRI 216369259No models in this size class
Non-ducted, up to 1.5 tons90.5(50 is the typical model of its size class) (higher)MST183G32MHAA46 of 46 models have all five ratings · AHRI 21808336623.7(50 is the typical model of its size class)APP10*3*1with ductless indoor unit APP10*3*1Also listed as APP10*3*2, APK10*3*2, APP10N4H1, APP10N3H1 and 9 more66 of 66 models have all five ratings · AHRI 213607325
Non-ducted, 2 tons86.1(50 is the typical model of its size class)RXTA24AAVJU*13 of 13 models have all five ratings · AHRI 217178408No models in this size class
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class)MST273G32MHAA11 of 11 models have all five ratings · AHRI 218083369No models in this size class
Non-ducted, 3.5 to 4.5 tons48.1(50 is the typical model of its size class)RXLA48AAVJU*7 of 7 models have all five ratings · AHRI 217178413No models in this size class
Non-ducted, 5 tons and up48.7(50 is the typical model of its size class)RXTA60AAVJU*1 of 1 models have all five ratings · AHRI 217178411No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingDaikinEphoca
COP at 5°Fbeats 100% · 2.50RXTA36AAVJU*Non-ducted, 2.5 to 3 tonsbeats 70% · 2.01AVP20R3H1-2Also listed as AVP20R4H1, AVP20N4H1, AVP20R3H1, AVP20N3H1 and 18 moreDucted, up to 1.5 tons
Capacity retention at 5°Fbeats 99% · 109%RZA30AAVJU*Non-ducted, 2.5 to 3 tonsbeats 86% · 95%AVK09R3H2Also listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 moreDucted, up to 1.5 tons
HSPF2beats 96% · 10.5MST273G32MHAADucted, 2.5 to 3 tonsbeats 69% · 9.9AVP10*3*1Also listed as AVP10*3*2, AVE10*3*2, AVK10*3*2, AXP10*3*1 and 35 moreDucted, up to 1.5 tons
SEER2beats 98% · 21.0DH9VSA361CA*Also sold as Amana AZV9SA361CA, Goodman GZV9SA361CADucted, 2.5 to 3 tonsbeats 45% · 15.4AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons
EER2beats 100% · 14.5MST183G32MHAADucted, up to 1.5 tonsbeats 55% · 11.7AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 21,600 Btu/hRXM18WVJU*Non-ducted, up to 1.5 tonsbeats 68% · 12,000 Btu/hAVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Daikin vs Ephoca: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Daikin (median, middle 50%)
  • Ephoca (median, middle 50%)
Heating capacity, % of its 47°F maximum70%57%COP at maximum capacity2.001.75

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Daikin: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Daikin, 47°F135100%100%100%100%100%
Daikin, 17°F13567%72%80%90%101%
Daikin, 5°F13553%60%70%75%87%
Daikin: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Daikin, 47°F1352.923.173.33.583.92
Daikin, 17°F1352.092.242.32.552.74
Daikin, 5°F1351.81.822.12.23
Ephoca: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Ephoca, 47°F174100%100%100%100%100%
Ephoca, 17°F17460%60%65%69%73%
Ephoca, 5°F17448%56%57%58%67%
Ephoca: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Ephoca, 47°F1742.752.842.843.463.47
Ephoca, 17°F1741.912.022.022.322.33
Ephoca, 5°F1741.751.751.751.751.95

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter