- Insights
- Manufacturers
- Ephoca
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Ephoca heat pump efficiency: 382 outdoor models compared
Ephoca has 382 heat pump outdoor models certified with this refrigerant group, in 382 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Ephoca makes. Ephoca has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 382
- AHRI certifications
- 382
- Efficiency index
- 31%
- Typical model vs same-size, same-type peers (382 models)
- Meet CEE 2025
- 0%
- 0 models
How Ephoca compares with comparable models
- Ephoca
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index382 models scored | 31% | Not ranked | — |
| COP at 5°F382 models scored | 21% | Not ranked | 1.75 |
| Capacity retention at 5°F382 models scored | 51% | Not ranked | 73% |
| HSPF2382 models scored | 40% | Not ranked | 9.2 |
| SEER2382 models scored | 21% | Not ranked | 15.2 |
| EER2382 models scored | 28% | Not ranked | 11.0 |
| Heating capacity at 5°F382 models scored | 21% | Not ranked | 6,500 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0% | 0 |
| CEE 2026 Tier 1 (Split ASHP) | 0% | 0 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 31.4% | 120 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 48.7% | 186 |
Sizes and duct types offered
- Ephoca (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 316 | 33% | 24% | 44% | 25% |
| Non-ducted, up to 1.5 tons | 66 | 22% | 5% | 18% | 2% |
Every Ephoca model in the market
- Ephoca models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Ephoca models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1AVK09R3H2Ephoca · AIO V SeriesAlso listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 more | 0.5 tons7,500 Btu/h · Ducted | 95% | 1.75 | 9.9 | 7,800 | 15.4 | XcelES CC | 1 | 217607099 | Ducted, up to 1.5 tons | 60.8 |
| 2AVP19R4H1Ephoca · AIO V SeriesAlso listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 more | 1 ton11,600 Btu/h · Ducted | 85% | 1.95 | 9.2 | 12,000 | 15.4 | XcelES CC | 1 | 217650520 | Ducted, up to 1.5 tons | 57.0 |
| 3ADP09R4H1Ephoca · AIO D SeriesAlso listed as ADP09N4H1, ADP09R3H1, ADP09N3H1, ADP09R4H2 and 45 more | 0.5 tons6,100 Btu/h · Ducted | 90% | 1.75 | 9.2 | 7,400 | 15.3 | XcelES CC | 1 | 217652213 | Ducted, up to 1.5 tons | 51.6 |
| 4AVP10*3*1Ephoca · AIO V SeriesAlso listed as AVP10*3*2, AVE10*3*2, AVK10*3*2, AXP10*3*1 and 35 more | 0.5 tons8,900 Btu/h · Ducted | 73% | 1.72 | 9.9 | 6,500 | 14.4 | None | 1 | 213607333 | Ducted, up to 1.5 tons | 43.8 |
| 5ACK09R3H1Ephoca · AIO C SeriesAlso listed as ACK09R3H2, ACK09N3H1, ACK09N3H2, ACU09R3H1 and 7 more | 0.5 tons6,100 Btu/h · Ducted | 72% | 1.75 | 9.2 | 5,900 | 15.3 | XcelES CC | 1 | 218330575 | Ducted, up to 1.5 tons | 36.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1AVP19R4H1Ephoca · AIO V SeriesAlso listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 more | 1 ton11,600 Btu/h · Ducted | 85% | 1.95 | 9.2 | 15.4 | 11.7 | XcelES CC | 1 | 217650520 | Ducted, up to 1.5 tons | 54.1 | 57.0 | 51.3 | 57.0 |
| 2AVK09R3H2Ephoca · AIO V SeriesAlso listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 more | 0.5 tons7,500 Btu/h · Ducted | 95% | 1.75 | 9.9 | 15.4 | 11.6 | XcelES CC | 1 | 217607099 | Ducted, up to 1.5 tons | 52.7 | 60.8 | 44.7 | 60.8 |
| 3ADP09R4H1Ephoca · AIO D SeriesAlso listed as ADP09N4H1, ADP09R3H1, ADP09N3H1, ADP09R4H2 and 45 more | 0.5 tons6,100 Btu/h · Ducted | 90% | 1.75 | 9.2 | 15.3 | 11.6 | XcelES CC | 1 | 217652213 | Ducted, up to 1.5 tons | 45.7 | 51.6 | 39.8 | 51.6 |
| 4ACK09R3H1Ephoca · AIO C SeriesAlso listed as ACK09R3H2, ACK09N3H1, ACK09N3H2, ACU09R3H1 and 7 more | 0.5 tons6,100 Btu/h · Ducted | 72% | 1.75 | 9.2 | 15.3 | 11.6 | XcelES CC | 1 | 218330575 | Ducted, up to 1.5 tons | 38.3 | 36.8 | 39.8 | 36.8 |
| 5AVP20R3H1-2Ephoca · AIO V SeriesAlso listed as AVP20R4H1, AVP20N4H1, AVP20R3H1, AVP20N3H1 and 18 more | 1.5 tons20,200 Btu/h · Ducted | 48% | 2.01 | 9.2 | 13.9 | 11.7 | None | 1 | 217595434 | Ducted, up to 1.5 tons | 36.2 | 39.0 | 33.3 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | AVP20R3H1-2Also listed as AVP20R4H1, AVP20N4H1, AVP20R3H1, AVP20N3H1 and 18 more | 2.01 | Ducted, up to 1.5 tons | 69% | 217595434 |
| Capacity retention at 5°F | AVK09R3H2Also listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 more | 95% | Ducted, up to 1.5 tons | 86% | 217607099 |
| HSPF2 | AVP10*3*1Also listed as AVP10*3*2, AVE10*3*2, AVK10*3*2, AXP10*3*1 and 35 more | 9.9 | Ducted, up to 1.5 tons | 68% | 213607333 |
| SEER2 | AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 more | 15.4 | Ducted, up to 1.5 tons | 44% | 217650520 |
| EER2 | AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 more | 11.7 | Ducted, up to 1.5 tons | 53% | 217650520 |
| Heating capacity at 5°F | AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 more | 12,000 Btu/h | Ducted, up to 1.5 tons | 68% | 217650520 |
Ephoca size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 60.8(50 is the typical model of its size class)AVK09R3H2Also listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 more285 of 316 models qualify · AHRI 217607099 | 54.1(50 is the typical model of its size class)AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 more316 of 316 models have all five ratings · AHRI 217650520 |
| Non-ducted, up to 1.5 tons | 32.2(50 is the typical model of its size class)AWP09R3H1Also listed as AWP09N3H1, AWP09R3H2, AWP09N3H2, AWE09R3H2 and 35 more66 of 66 models qualify · AHRI 217677964 | 23.2(50 is the typical model of its size class)APP10*3*1with ductless indoor unit APP10*3*1Also listed as APP10*3*2, APK10*3*2, APP10N4H1, APP10N3H1 and 9 more66 of 66 models have all five ratings · AHRI 213607325 |
Newest Ephoca certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| AFE09N3H2-2Ephoca · AIO F Series | 0.5 tons6,700 Btu/h · Ducted | 1.77 | 67% | 8.6 | 15.2 | None | 1 | 218797182 |
| AFE09N3H1-2Ephoca · AIO F Series | 0.5 tons6,700 Btu/h · Ducted | 1.77 | 67% | 8.6 | 15.2 | None | 1 | 218797181 |
| AFE09R3H2-2Ephoca · AIO F Series | 0.5 tons6,700 Btu/h · Ducted | 1.77 | 67% | 8.6 | 15.2 | None | 1 | 218797180 |
| AFE09R3H1-2Ephoca · AIO F Series | 0.5 tons6,700 Btu/h · Ducted | 1.77 | 67% | 8.6 | 15.2 | None | 1 | 218797179 |
| AFP09N3H2-2Ephoca · AIO F Series | 0.5 tons6,700 Btu/h · Ducted | 1.77 | 67% | 8.6 | 15.2 | None | 1 | 218797178 |
Compare Ephoca
Ephoca includes these brand names as listed in AHRI: Ephoca. Standards are checked against published thresholds; program rules beyond ratings are not checked.