Both views use the same certified data. This device remembers your choice.
Lennox vs Trane heat pumps
Measured against models of the same size and duct type, Lennox scores higher on 3 of the 6 ratings. Lennox has 341 outdoor models, Trane has 370 outdoor models.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Lennox
- Trane
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Lennox | Trane |
|---|---|---|
| Efficiency index | 48%median — · 24th ranked | 50%median — · 19th ranked |
| COP at 5°F | 46%median 1.94 · 22nd ranked | 69%median 2.27 · 1st ranked |
| Capacity retention at 5°F | 43%median 61% · 23rd ranked | 43%median 65% · 25th ranked |
| HSPF2 | 44% (higher)median 8.1 · 22nd ranked | 35% (higher)median 7.5 · 27th ranked |
| SEER2 | 44% (higher)median 16.0 · 21st ranked | 40% (higher)median 15.5 · 26th ranked |
| EER2 | 57%median 11.7 · 12th ranked | 67%median 11.7 · 3rd ranked |
| Heating capacity at 5°F | 45% (higher)median 19,000 Btu/h · 23rd ranked | 44% (higher)median 21,400 Btu/h · 25th ranked |
| Outdoor models | 341 | 370 |
| AHRI certifications | 67,116 | 93,740 |
Share of models meeting each standard
| Standard | Lennox | Trane |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 43.1%147 models | 38.6%143 models |
| CEE 2026 Tier 1 (Split ASHP) | 40.8%139 models | 36.2%134 models |
| CEE Advanced Tier (Split ASHP) | 2.6%9 models | 2.4%9 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 35.5%121 models | 25.4%94 models |
| DOE Cold Climate Heat Pump Challenge | 2.6%9 models | 2.4%9 models |
| ENERGY STAR Cold Climate | 29.3%100 models | 16.8%62 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Lennox
- Trane
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Lennox | Trane |
|---|---|---|
| Ducted, up to 1.5 tons | 23 · index 60% | 19 · index 49% |
| Ducted, 2 tons | 48 · index 46% | 40 · index 42% |
| Ducted, 2.5 to 3 tons | 85 · index 45% | 108 · index 50% |
| Ducted, 3.5 to 4.5 tons | 101 · index 44% | 133 · index 53% |
| Ducted, 5 tons and up | 30 · index 47% | 46 · index 50% |
| Non-ducted, up to 1.5 tons | 50 · index 54% | 15 · index 55% |
| Non-ducted, 2 tons | 18 · index 58% | 4 · index 44% |
| Non-ducted, 2.5 to 3 tons | 20 · index 58% | 7 · index 56% |
| Non-ducted, 3.5 to 4.5 tons | 8 · index 47% | 3 · index 63% |
| Non-ducted, 5 tons and up | 4 · index 57% | 2 · index 68% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | LennoxCold-climate score, best model | TraneCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 87.0(50 is the typical model of its size class)A-VXP18SA-1with ducted air handler WXP18SA15 of 23 models qualify · AHRI 217482406 | 92.7(50 is the typical model of its size class) (higher)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCB6 of 21 models qualify · AHRI 216794262 |
| Ducted, 2 tons | 88.5(50 is the typical model of its size class) (higher)SL22KLV-024-230A**with ducted air handler CBK48MVT-042-230-26 of 51 models qualify · AHRI 216379010 | 77.9(50 is the typical model of its size class)5A6H7024A1with ducted air handler CM24D3J+TDR13 of 38 models qualify · AHRI 217155223 |
| Ducted, 2.5 to 3 tons | 93.6(50 is the typical model of its size class)SL22KLV-036-230A**with ducted air handler CBK48MVT-060-230-29 of 82 models qualify · AHRI 216776011 | 95.1(50 is the typical model of its size class) (higher)5TCV0X36A1with ducted air handler 5TAMXD06AV41Also sold as American Standard 5A5V0X36A126 of 108 models qualify · AHRI 218868829 |
| Ducted, 3.5 to 4.5 tons | 90.6(50 is the typical model of its size class)SL22KLV-060-230A**with indoor coil D(A,C,E)60D3J+TDR and furnace SLP99UH110XV60C27 of 100 models qualify · AHRI 217443918 | 92.8(50 is the typical model of its size class) (higher)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace S9V2D120U5PSC+LRP39 of 133 models qualify · AHRI 216794596 |
| Ducted, 5 tons and up | 84.3(50 is the typical model of its size class) (higher)VPD060H6M-5P5 of 31 models qualify · AHRI 216054512 | 81.8(50 is the typical model of its size class)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA2 of 46 models qualify · AHRI 218451025 |
| Non-ducted, up to 1.5 tons | 97.0(50 is the typical model of its size class) (higher)A-VHP06SA-1with ductless indoor unit B-VHP06SA-131 of 50 models qualify · AHRI 216097104 | 70.1(50 is the typical model of its size class)M5THM2318A12NA*15 of 15 models qualify · AHRI 218067082 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class) (higher)A-VHP24SA-1with ductless indoor unit B-VHP24CA-111 of 18 models qualify · AHRI 217482451 | 39.6(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models qualify · AHRI 215385437 |
| Non-ducted, 2.5 to 3 tons | 82.8(50 is the typical model of its size class) (higher)VPD036S6M-5P15 of 20 models qualify · AHRI 216054505 | 74.4(50 is the typical model of its size class)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA5 of 7 models qualify · AHRI 218451026 |
| Non-ducted, 3.5 to 4.5 tons | 73.6(50 is the typical model of its size class) (higher)A-VHP486A-16 of 8 models qualify · AHRI 216097135 | 67.5(50 is the typical model of its size class)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models qualify · AHRI 218451027 |
| Non-ducted, 5 tons and up | 84.1(50 is the typical model of its size class) (higher)VPD060H6M-5P4 of 4 models qualify · AHRI 216054508 | 64.2(50 is the typical model of its size class)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models qualify · AHRI 218451028 |
All-around best
| Size and duct type | LennoxAll-around score, best model | TraneAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 87.0(50 is the typical model of its size class) (higher)A-VHP09SA-1with ducted air handler B-VHP09DA-122 of 23 models have all five ratings · AHRI 217482441 | 85.1(50 is the typical model of its size class)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace *UHMB060CCV3+LRP18 of 18 models have all five ratings · AHRI 216794699 |
| Ducted, 2 tons | 90.0(50 is the typical model of its size class) (higher)A-ZHP24SA-1with ducted air handler B-ZHP24SA-146 of 47 models have all five ratings · AHRI 218027842 | 81.5(50 is the typical model of its size class)5A6V0X24A1with indoor coil 5PX*BD06AS3 and furnace S9V2B060D3VSB+VCKIT28 of 28 models have all five ratings · AHRI 218036320 |
| Ducted, 2.5 to 3 tons | 95.0(50 is the typical model of its size class)SL22KLV-036-230A**with ducted air handler CBK48MVT-060-230-84 of 84 models have all five ratings · AHRI 216776011 | 95.7(50 is the typical model of its size class) (higher)5TCV0X36A1with ducted air handler 5PX*D010AS3+P0V0D000M50SD+LRPAlso sold as American Standard 5A5V0X36A175 of 111 models have all five ratings · AHRI 218868823 |
| Ducted, 3.5 to 4.5 tons | 86.5(50 is the typical model of its size class)SL22KLV-048-230A**with indoor coil CK40[C,U]T-60C-**+TDR and furnace SL280UH080NV60C97 of 97 models have all five ratings · AHRI 216776088 | 89.2(50 is the typical model of its size class) (higher)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace L8V1C100U5VSB+LRP107 of 143 models have all five ratings · AHRI 216794476 |
| Ducted, 5 tons and up | 84.7(50 is the typical model of its size class) (higher)VPD060H6M-5P36 of 36 models have all five ratings · AHRI 216054512 | 74.8(50 is the typical model of its size class)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA9 of 46 models have all five ratings · AHRI 218451025 |
| Non-ducted, up to 1.5 tons | 96.6(50 is the typical model of its size class) (higher)A-VHP06SA-1with ductless indoor unit B-VHP06SA-142 of 50 models have all five ratings · AHRI 216097104 | 73.9(50 is the typical model of its size class)M5THM2318A12NA*15 of 15 models have all five ratings · AHRI 218067082 |
| Non-ducted, 2 tons | 89.2(50 is the typical model of its size class) (higher)A-KZP24SA-1with ductless indoor unit B-KZP24SA-113 of 18 models have all five ratings · AHRI 218027843 | 51.4(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models have all five ratings · AHRI 215385437 |
| Non-ducted, 2.5 to 3 tons | 79.2(50 is the typical model of its size class) (higher)VPD036S6M-5P16 of 20 models have all five ratings · AHRI 216054505 | 76.7(50 is the typical model of its size class)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA7 of 7 models have all five ratings · AHRI 218451026 |
| Non-ducted, 3.5 to 4.5 tons | 75.4(50 is the typical model of its size class) (higher)A-VHP486A-17 of 8 models have all five ratings · AHRI 216097133 | 73.8(50 is the typical model of its size class)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models have all five ratings · AHRI 218451027 |
| Non-ducted, 5 tons and up | 91.6(50 is the typical model of its size class) (higher)VPD060H6M-5P4 of 4 models have all five ratings · AHRI 216054508 | 68.0(50 is the typical model of its size class)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models have all five ratings · AHRI 218451028 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Lennox | Trane |
|---|---|---|
| COP at 5°F | beats 100% · 4.067HP14F30P-**ADucted, 2.5 to 3 tons | beats 100% · 3.205TWR4036A1Ducted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 100% · 150%A-ZHP06SA-1Non-ducted, up to 1.5 tons | beats 100% · 136%5A6H7036A1Ducted, 2.5 to 3 tons |
| HSPF2 | beats 100% · 15.6A-ZHP06SA-1Non-ducted, up to 1.5 tons | beats 100% · 13.53TXK2224AF00HAAAlso listed as 3TXK2236AF00HAA, 3TVHS036SF000AADucted, 2.5 to 3 tons |
| SEER2 | beats 100% · 27.0A-ZHP15SA-1Ducted, up to 1.5 tons | beats 99% · 21.65TWV0X36A1Also sold as American Standard 5A6V0X36A1Ducted, 2.5 to 3 tons |
| EER2 | beats 100% · 14.07HP14F36P-**AAlso sold as Armstrong Air A7HP14F36P-**ADucted, 2.5 to 3 tons | beats 99% · 13.55TCV0X36A1Also sold as American Standard 5A5V0X36A1Ducted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 100% · 54,000 Btu/hMMLD024S6S-1PNon-ducted, 2 tons | beats 100% · 27,200 Btu/h5TWV0X24A1Ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Lennox (median, middle 50%)
- Trane (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Lennox, 47°F | 142 | 100% | 100% | 100% | 100% | 100% |
| Lennox, 17°F | 142 | 66% | 69% | 78% | 84% | 90% |
| Lennox, 5°F | 142 | 56% | 62% | 71% | 79% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Lennox, 47°F | 142 | 2.71 | 3 | 3.22 | 3.47 | 3.6 |
| Lennox, 17°F | 142 | 2 | 2.17 | 2.34 | 2.47 | 2.61 |
| Lennox, 5°F | 142 | 1.8 | 1.84 | 2 | 2.2 | 2.3 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Trane, 47°F | 52 | 100% | 100% | 100% | 100% | 100% |
| Trane, 17°F | 52 | 71% | 73% | 85% | 90% | 93% |
| Trane, 5°F | 52 | 57% | 64% | 70% | 73% | 76% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Trane, 47°F | 52 | 2.47 | 2.92 | 3.14 | 3.66 | 4 |
| Trane, 17°F | 52 | 2.14 | 2.2 | 2.4 | 2.5 | 2.6 |
| Trane, 5°F | 52 | 1.8 | 1.96 | 2.1 | 2.2 | 2.22 |
Source: NEEP ccASHP list · as of