Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Innova vs Lennox heat pumps
Measured against models of the same size and duct type, Lennox scores higher on 5 of the 6 ratings. Innova has 332 outdoor models, Lennox has 331 outdoor models. Innova has no QMID on file and is not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Innova
- Lennox
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Innova | Lennox |
|---|---|---|
| Efficiency index | 32%median — | 48%median — · 22nd ranked |
| COP at 5°F | 22%median 1.75 | 46%median 1.95 · 21st ranked |
| Capacity retention at 5°F | 50% (higher)median 73% | 43% (higher)median 62% · 22nd ranked |
| HSPF2 | 41%median 9.2 | 44%median 8.1 · 21st ranked |
| SEER2 | 22%median 15.2 | 45%median 16.0 · 21st ranked |
| EER2 | 29%median 11.0 | 57%median 11.7 · 11th ranked |
| Heating capacity at 5°F | 22%median 6,500 Btu/h | 45%median 19,000 Btu/h · 22nd ranked |
| Outdoor models | 332 | 331 |
| AHRI certifications | 332 | 65,305 |
Share of models meeting each standard
| Standard | Innova | Lennox |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 43.8%145 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 41.4%137 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 2.7%9 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 31.9%106 models | 35.6%118 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 2.7%9 models |
| ENERGY STAR Cold Climate | 48.5%161 models | 29.9%99 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Innova
- Lennox
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Innova | Lennox |
|---|---|---|
| Ducted, up to 1.5 tons | 277 · index 34% | 23 · index 59% |
| Ducted, 2 tons | None | 48 · index 46% |
| Ducted, 2.5–3 tons | None | 86 · index 45% |
| Ducted, 3.5–4.5 tons | None | 100 · index 44% |
| Ducted, 5 tons and up | None | 30 · index 46% |
| Non-ducted, up to 1.5 tons | 55 · index 22% | 44 · index 55% |
| Non-ducted, 2 tons | None | 16 · index 57% |
| Non-ducted, 2.5–3 tons | None | 16 · index 60% |
| Non-ducted, 3.5–4.5 tons | None | 6 · index 51% |
| Non-ducted, 5 tons and up | None | 4 · index 57% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | InnovaCold-climate score, best model | LennoxCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 60.8(50 is the typical model of its size class)AVK09R3H2Also listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 more246 of 277 models qualify · AHRI 218329872 | 86.6(50 is the typical model of its size class) (higher)A-VXP18SA-1with ducted air handler WXP18SA16 of 23 models qualify · AHRI 217482406 |
| Ducted, 2 tons | No models in this size class | 88.5(50 is the typical model of its size class)SL22KLV-024-230A**with ducted air handler CBK48MVT-042-230-27 of 51 models qualify · AHRI 216379010 |
| Ducted, 2.5–3 tons | No models in this size class | 93.4(50 is the typical model of its size class)SL22KLV-036-230A**with ducted air handler CBK48MVT-060-230-29 of 83 models qualify · AHRI 216776011 |
| Ducted, 3.5–4.5 tons | No models in this size class | 90.8(50 is the typical model of its size class)SL22KLV-060-230A**with indoor coil D(A,C,E)60D3J+TDR and furnace SLP99UH110XV60C27 of 99 models qualify · AHRI 217443918 |
| Ducted, 5 tons and up | No models in this size class | 83.7(50 is the typical model of its size class)VPD060H6M-5P5 of 31 models qualify · AHRI 216054512 |
| Non-ducted, up to 1.5 tons | 32.2(50 is the typical model of its size class)AWP09R3H1Also listed as AWP09N3H1, AWP09R3H2, AWP09N3H2, AWE09R3H2 and 24 more55 of 55 models qualify · AHRI 218329994 | 96.7(50 is the typical model of its size class) (higher)A-VHP06SA-1with ductless indoor unit B-VHP06SA-131 of 44 models qualify · AHRI 216097104 |
| Non-ducted, 2 tons | No models in this size class | 89.4(50 is the typical model of its size class)A-VHP24SA-1with ductless indoor unit B-VHP24CA-112 of 16 models qualify · AHRI 217482451 |
| Non-ducted, 2.5–3 tons | No models in this size class | 82.5(50 is the typical model of its size class)VPD036S6M-5P14 of 16 models qualify · AHRI 216054505 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 73.4(50 is the typical model of its size class)A-VHP486A-15 of 6 models qualify · AHRI 216097135 |
| Non-ducted, 5 tons and up | No models in this size class | 84.1(50 is the typical model of its size class)VPD060H6M-5P4 of 4 models qualify · AHRI 216054508 |
All-around best
| Size and duct type | InnovaAll-around score, best model | LennoxAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 54.1(50 is the typical model of its size class)AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 more277 of 277 models have all five ratings · AHRI 218329931 | 86.5(50 is the typical model of its size class) (higher)A-VHP09SA-1with ducted air handler B-VHP09DA-123 of 23 models have all five ratings · AHRI 217482441 |
| Ducted, 2 tons | No models in this size class | 89.9(50 is the typical model of its size class)A-ZHP24SA-1with ducted air handler B-ZHP24SA-147 of 47 models have all five ratings · AHRI 218027842 |
| Ducted, 2.5–3 tons | No models in this size class | 95.0(50 is the typical model of its size class)SL22KLV-036-230A**with ducted air handler CBK48MVT-060-230-84 of 84 models have all five ratings · AHRI 216776011 |
| Ducted, 3.5–4.5 tons | No models in this size class | 86.7(50 is the typical model of its size class)SL22KLV-048-230A**with indoor coil CK40[C,U]T-60C-**+TDR and furnace SL280UH080NV60C97 of 97 models have all five ratings · AHRI 216776088 |
| Ducted, 5 tons and up | No models in this size class | 84.6(50 is the typical model of its size class)VPD060H6M-5P36 of 36 models have all five ratings · AHRI 216054512 |
| Non-ducted, up to 1.5 tons | 23.2(50 is the typical model of its size class)APP10*3*1Also listed as APP10*3*2, APK10*3*2, APP10N4H1, APP10N3H1 and 9 more55 of 55 models have all five ratings · AHRI 218329814 | 96.2(50 is the typical model of its size class) (higher)A-VHP06SA-1with ductless indoor unit B-VHP06SA-140 of 44 models have all five ratings · AHRI 216097104 |
| Non-ducted, 2 tons | No models in this size class | 88.4(50 is the typical model of its size class)A-KZP24SA-1with ductless indoor unit B-KZP24SA-114 of 16 models have all five ratings · AHRI 218027843 |
| Non-ducted, 2.5–3 tons | No models in this size class | 78.8(50 is the typical model of its size class)VPD036S6M-5P15 of 16 models have all five ratings · AHRI 216054505 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 75.6(50 is the typical model of its size class)A-VHP486A-16 of 6 models have all five ratings · AHRI 216097133 |
| Non-ducted, 5 tons and up | No models in this size class | 91.6(50 is the typical model of its size class)VPD060H6M-5P4 of 4 models have all five ratings · AHRI 216054508 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Innova | Lennox |
|---|---|---|
| COP at 5°F | beats 69% · 2.01AVP20R3H1-2Also listed as AVP20R4H1, AVP20N4H1, AVP20R3H1, AVP20N3H1 and 18 moreDucted, up to 1.5 tons | beats 100% · 4.067HP14F30P-**ADucted, 2.5–3 tons |
| Capacity retention at 5°F | beats 86% · 95%AVK09R3H2Also listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 moreDucted, up to 1.5 tons | beats 100% · 150%A-ZHP06SA-1Non-ducted, up to 1.5 tons |
| HSPF2 | beats 68% · 9.9AVP10*3*1Also listed as AVP10*3*2, AVE10*3*2, AVK10*3*2, AXP10*3*1 and 35 moreDucted, up to 1.5 tons | beats 100% · 15.6A-ZHP06SA-1Non-ducted, up to 1.5 tons |
| SEER2 | beats 44% · 15.4AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons | beats 100% · 27.0A-ZHP15SA-1Ducted, up to 1.5 tons |
| EER2 | beats 53% · 11.7AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons | beats 100% · 15.0EL16KP1-018-230A**Also listed as ML14KP1-018-230ADucted, up to 1.5 tons |
| Heating capacity at 5°F | beats 68% · 12,000 Btu/hAVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons | beats 100% · 54,000 Btu/hMMLD024S6S-1PNon-ducted, 2 tons |