Century heat pump efficiency: 59 outdoor models compared

Century has 59 heat pump outdoor models certified with this refrigerant group, in 1,147 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Century makes. Century has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
59
AHRI certifications
1,147
Efficiency index
50%
Typical model vs same-size, same-type peers (68 models)
Meet CEE 2025
44.1%
26 models

How Century compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Century against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of Century’s own modelsCentury is strongest on EER2 (its typical model beats 53% of comparable models) and weakest on SEER2 (45%).
  • Century
  • Middle half of its models
  • Other ranked manufacturers
Century

Source: AHRI Directory, NEEP · as of

Average peer percentile of Century’s models
RatingBeats comparable modelsRankRaw median
Efficiency index68 models scored50%Not ranked—
COP at 5°F68 models scored50%Not ranked1.98
Capacity retention at 5°F68 models scored49%Not ranked63%
HSPF268 models scored52%Not ranked8.1
SEER268 models scored45%Not ranked15.2
EER268 models scored53%Not ranked11.4
Heating capacity at 5°F68 models scored49%Not ranked19,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Century’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • Century (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons872%69%71%69%
Ducted, 2 tons1341%47%43%37%
Ducted, 2.5–3 tons1442%48%40%34%
Ducted, 3.5–4.5 tons2139%42%39%39%
Non-ducted, up to 1.5 tons677%60%84%69%
Non-ducted, 2 tons176%94%98%49%
Non-ducted, 2.5–3 tons367%46%83%57%
Non-ducted, 3.5–4.5 tons267%52%82%70%

Every Century model in the market

Century’s 68 models with a known size and duct type, over the shape of the whole catalog.
Century models by size and ratingColoured: Century · grey shapes: all 14,508 models · lines: catalog medians by size
  • Century models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 68 century models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top Century models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 Century cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1A-VHP06SA-1CENTURY · A Serieswith ductless indoor unit B-VHP06SA-10.5 tons6,000 Btu/h · Non-ducted110%2.4014.87,70025.5CEE 25CEE 26CEE AdvXcelDOEES CC2218425153Non-ducted, up to 1.5 tons96.7
2A-VHP24SA-1CENTURY · A Serieswith ductless indoor unit B-VHP24CA-12 tons23,400 Btu/h · Non-ducted95%2.2311.623,80020.7CEE 25CEE 26XcelES CC5217482468Non-ducted, 2 tons89.4
3A-VXP18SA-1CENTURY · A Serieswith ducted air handler WXP18SA1.5 tons18,000 Btu/h · Ducted103%2.1010.819,60019.3CEE 25CEE 26CEE AdvXcelDOEES CC4217482412Ducted, up to 1.5 tons86.6
4A-ZHP09SA-1CENTURY · A-ZHP Serieswith ductless indoor unit B-ZHP09SA-11 ton9,000 Btu/h · Non-ducted113%2.0014.613,50033.3CEE 25CEE 26XcelES CC1218404564Non-ducted, up to 1.5 tons85.9
5A-VHP24SA-1CENTURY · A Serieswith ducted air handler B-VHP24DA-12 tons24,000 Btu/h · Ducted92%2.1811.724,00019.0CEE 25CEE 26XcelES CC5217482470Ducted, 2 tons85.7

All-around best

Top 5 Century models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1A-VHP06SA-1CENTURY · A Serieswith ductless indoor unit B-VHP06SA-10.5 tons6,000 Btu/h · Non-ducted110%2.4014.825.518.0CEE 25CEE 26CEE AdvXcelDOEES CC2218425153Non-ducted, up to 1.5 tons96.296.795.796.7
2A-ZHP09SA-1CENTURY · A-ZHP Serieswith ductless indoor unit B-ZHP09SA-11 ton9,000 Btu/h · Non-ducted113%2.0014.633.317.0CEE 25CEE 26XcelES CC1218404564Non-ducted, up to 1.5 tons92.385.998.785.9
3A-VHP09SA-1CENTURY · A Serieswith ducted air handler B-VHP09DA-11 ton9,000 Btu/h · Ducted120%1.8513.820.514.0CEE 25CEE 26XcelES CC5217482458Ducted, up to 1.5 tons86.579.993.279.9
4A-VHP486A-1CENTURY · A Series4 tons47,000 Btu/h · Ducted100%2.0011.020.411.7CEE 25CEE 26XcelES CC3218425169Ducted, 3.5–4.5 tons83.982.785.182.7
5A-ZHP15SA-1CENTURY · A-ZHP Serieswith ducted air handler B-ZHP15SA-11.5 tons15,000 Btu/h · Ducted90%2.0011.027.013.0CEE 25CEE 26XcelES CC1218404563Ducted, up to 1.5 tons83.975.192.775.1

Best model on each rating

Century’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FSHP1448S1A2.75Ducted, 3.5–4.5 tons98%218426983
Capacity retention at 5°FA-VHP09SA-1126%Non-ducted, up to 1.5 tons98%217482457
HSPF2A-VHP06SA-114.8Non-ducted, up to 1.5 tons99%218425153
SEER2A-ZHP15SA-127.0Ducted, up to 1.5 tons100%218404563
EER2A-VHP06SA-118.0Non-ducted, up to 1.5 tons99%218425153
Heating capacity at 5°FA-VXP18SA-119,600 Btu/hDucted, up to 1.5 tons98%217482412

All 59 Century models in Explore

Century size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Century: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons86.6(50 is the typical model of its size class)A-VXP18SA-1with ducted air handler WXP18SA6 of 8 models qualify · AHRI 21748241286.5(50 is the typical model of its size class)A-VHP09SA-1with ducted air handler B-VHP09DA-18 of 8 models have all five ratings · AHRI 217482458
Ducted, 2 tons85.7(50 is the typical model of its size class)A-VHP24SA-1with ducted air handler B-VHP24DA-17 of 14 models qualify · AHRI 21748247078.4(50 is the typical model of its size class)A-VHP24SA-1with ducted air handler B-VHP24DA-112 of 12 models have all five ratings · AHRI 217482470
Ducted, 2.5–3 tons82.5(50 is the typical model of its size class)A-VHP365A-14 of 13 models qualify · AHRI 21842516683.6(50 is the typical model of its size class)A-VHP365A-113 of 13 models have all five ratings · AHRI 218425166
Ducted, 3.5–4.5 tons82.7(50 is the typical model of its size class)A-VHP486A-18 of 21 models qualify · AHRI 21842516983.9(50 is the typical model of its size class)A-VHP486A-122 of 22 models have all five ratings · AHRI 218425169
Ducted, 5 tons and upNo models in this size class66.7(50 is the typical model of its size class)HSA1460S1-**Awith ducted air handler HMA60VX1*-1 of 1 models have all five ratings · AHRI 216370485
Non-ducted, up to 1.5 tons96.7(50 is the typical model of its size class)A-VHP06SA-1with ductless indoor unit B-VHP06SA-16 of 6 models qualify · AHRI 21842515396.2(50 is the typical model of its size class)A-VHP06SA-1with ductless indoor unit B-VHP06SA-16 of 6 models have all five ratings · AHRI 218425153
Non-ducted, 2 tons89.4(50 is the typical model of its size class)A-VHP24SA-1with ductless indoor unit B-VHP24CA-11 of 1 models qualify · AHRI 21748246876.4(50 is the typical model of its size class)A-VHP24SA-1with ductless indoor unit B-VHP24SA-11 of 1 models have all five ratings · AHRI 218425157
Non-ducted, 2.5–3 tons78.0(50 is the typical model of its size class)A-VHP365A-13 of 3 models qualify · AHRI 21842516778.3(50 is the typical model of its size class)A-VHP365A-13 of 3 models have all five ratings · AHRI 218425165
Non-ducted, 3.5–4.5 tons73.4(50 is the typical model of its size class)A-VHP486A-12 of 2 models qualify · AHRI 21842517075.6(50 is the typical model of its size class)A-VHP486A-12 of 2 models have all five ratings · AHRI 218425168

All-around board, every manufacturer

Newest Century certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified Century outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
HSA1936V1-**ACentury · HSA19 SERIESwith ducted air handler HMAS24CX1S-2 tons23,800 Btu/h · Ducted1.7057%7.519.5CEE 25CEE 26Xcel148218598197
HSA1436S1-**ACentury · HSA14 SERIESwith ducted air handler HMAS42CX1S-3 tons36,000 Btu/h · Ducted1.9653%7.815.2None80218499736
HSA1460S1-**ACenturywith indoor coil D(A,C,E)60A4J+TDR and furnace GUH92C110C5MP4.5 tons52,000 Btu/h · Ducted2.4061%7.514.3None17218427188
HSA1448S1-**ACenturywith indoor coil D(A,C,E)60A4J+TDR and furnace GUH92C110C5MP3.5 tons44,000 Btu/h · Ducted2.4363%7.814.8None82218427184
HSA1442S1-**ACenturywith indoor coil D(A,C,E)48B4J+TDR and furnace GUH92C110C5MP3 tons38,500 Btu/h · Ducted2.5463%7.515.2None87218427165

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare Century

Manufacturers of a similar size, side by side.

Century includes these brand names as listed in AHRI: CENTURY. Standards are checked against published thresholds; program rules beyond ratings are not checked.