Century heat pump efficiency: 59 outdoor models compared
Century has 59 heat pump outdoor models certified with this refrigerant group, in 1,183 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Century makes. Century has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 59
- AHRI certifications
- 1,183
- Efficiency index
- 50%
- Typical model vs same-size, same-type peers (68 models)
- Meet CEE 2025
- 44.1%
- 26 models
How Century compares with comparable models
- Century
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index68 models scored | 50% | Not ranked | — |
| COP at 5°F68 models scored | 51% | Not ranked | 1.98 |
| Capacity retention at 5°F68 models scored | 49% | Not ranked | 63% |
| HSPF268 models scored | 52% | Not ranked | 8.1 |
| SEER268 models scored | 45% | Not ranked | 15.2 |
| EER268 models scored | 54% | Not ranked | 11.4 |
| Heating capacity at 5°F68 models scored | 49% | Not ranked | 19,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 44.1% | 26 |
| CEE 2026 Tier 1 (Split ASHP) | 44.1% | 26 |
| CEE Advanced Tier (Split ASHP) | 3.4% | 2 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 40.7% | 24 |
| DOE Cold Climate Heat Pump Challenge | 3.4% | 2 |
| ENERGY STAR Cold Climate | 32.2% | 19 |
Sizes and duct types offered
- Century (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 8 | 72% | 70% | 71% | 70% |
| Ducted, 2 tons | 13 | 41% | 47% | 43% | 37% |
| Ducted, 2.5 to 3 tons | 14 | 42% | 48% | 40% | 33% |
| Ducted, 3.5 to 4.5 tons | 21 | 39% | 42% | 39% | 39% |
| Non-ducted, up to 1.5 tons | 6 | 78% | 61% | 85% | 70% |
| Non-ducted, 2 tons | 1 | 78% | 95% | 98% | 52% |
| Non-ducted, 2.5 to 3 tons | 3 | 68% | 46% | 84% | 57% |
| Non-ducted, 3.5 to 4.5 tons | 2 | 67% | 52% | 83% | 69% |
Every Century model in the market
- Century models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Century in the cold
- All listed models (median, middle 50% and 80%)
- Century (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Century, 47°F | 27 | 100% | 100% | 100% | 100% | 100% |
| Century, 17°F | 27 | 68% | 70% | 78% | 84% | 85% |
| Century, 5°F | 27 | 64% | 69% | 75% | 81% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Century, 47°F | 27 | 2.8 | 3 | 3.21 | 3.43 | 3.53 |
| Century, 17°F | 27 | 1.95 | 2.02 | 2.3 | 2.41 | 2.6 |
| Century, 5°F | 27 | 1.8 | 1.84 | 2 | 2.05 | 2.2 |
Source: NEEP ccASHP list · as of
Top Century models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1A-VHP06SA-1CENTURY · A Serieswith ductless indoor unit B-VHP06SA-1 | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 7,700 | 25.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 218425153 | Non-ducted, up to 1.5 tons | 97.0 |
| 2A-VHP24SA-1CENTURY · A Serieswith ductless indoor unit B-VHP24CA-1 | 2 tons23,400 Btu/h · Non-ducted | 95% | 2.23 | 11.6 | 23,800 | 20.7 | CEE 25CEE 26XcelES CC | 5 | 217482468 | Non-ducted, 2 tons | 90.1 |
| 3A-VXP18SA-1CENTURY · A Serieswith ducted air handler WXP18SA | 1.5 tons18,000 Btu/h · Ducted | 103% | 2.10 | 10.8 | 19,600 | 19.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 217482412 | Ducted, up to 1.5 tons | 87.0 |
| 4A-ZHP09SA-1CENTURY · A-ZHP Serieswith ductless indoor unit B-ZHP09SA-1 | 1 ton9,000 Btu/h · Non-ducted | 113% | 2.00 | 14.6 | 13,500 | 33.3 | CEE 25CEE 26XcelES CC | 1 | 218404564 | Non-ducted, up to 1.5 tons | 86.5 |
| 5A-VHP24SA-1CENTURY · A Serieswith ducted air handler B-VHP24DA-1 | 2 tons24,000 Btu/h · Ducted | 92% | 2.18 | 11.7 | 24,000 | 19.0 | CEE 25CEE 26XcelES CC | 5 | 217482470 | Ducted, 2 tons | 85.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1A-VHP06SA-1CENTURY · A Serieswith ductless indoor unit B-VHP06SA-1 | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 25.5 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 218425153 | Non-ducted, up to 1.5 tons | 96.6 | 97.0 | 96.1 | 97.0 |
| 2A-ZHP09SA-1CENTURY · A-ZHP Serieswith ductless indoor unit B-ZHP09SA-1 | 1 ton9,000 Btu/h · Non-ducted | 113% | 2.00 | 14.6 | 33.3 | 17.0 | CEE 25CEE 26XcelES CC | 1 | 218404564 | Non-ducted, up to 1.5 tons | 92.7 | 86.5 | 98.8 | 86.5 |
| 3A-VHP09SA-1CENTURY · A Serieswith ducted air handler B-VHP09DA-1 | 1 ton9,000 Btu/h · Ducted | 120% | 1.85 | 13.8 | 20.5 | 14.0 | CEE 25CEE 26XcelES CC | 5 | 217482458 | Ducted, up to 1.5 tons | 87.0 | 80.4 | 93.5 | 80.4 |
| 4A-VHP09SA-1CENTURY · A Serieswith ductless indoor unit B-VHP09WA-1 | 1 ton9,000 Btu/h · Non-ducted | 126% | 1.84 | 10.9 | 27.2 | 15.1 | CEE 25CEE 26XcelES CC | 5 | 217482457 | Non-ducted, up to 1.5 tons | 84.4 | 72.6 | 96.1 | 74.2 |
| 5A-VHP486A-1CENTURY · A Series | 4 tons47,000 Btu/h · Ducted | 100% | 2.00 | 11.0 | 20.4 | 11.7 | CEE 25CEE 26XcelES CC | 3 | 218425169 | Ducted, 3.5 to 4.5 tons | 84.3 | 82.6 | 86.0 | 82.6 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | SHP1448S1A | 2.75 | Ducted, 3.5 to 4.5 tons | 98% | 218426983 |
| Capacity retention at 5°F | A-VHP09SA-1 | 126% | Non-ducted, up to 1.5 tons | 98% | 217482457 |
| HSPF2 | A-VHP06SA-1 | 14.8 | Non-ducted, up to 1.5 tons | 99% | 218425153 |
| SEER2 | A-ZHP15SA-1 | 27.0 | Ducted, up to 1.5 tons | 100% | 218404563 |
| EER2 | A-VHP06SA-1 | 18.0 | Non-ducted, up to 1.5 tons | 99% | 218425153 |
| Heating capacity at 5°F | A-VXP18SA-1 | 19,600 Btu/h | Ducted, up to 1.5 tons | 98% | 217482412 |
Century size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 87.0(50 is the typical model of its size class)A-VXP18SA-1with ducted air handler WXP18SA6 of 8 models qualify · AHRI 217482412 | 87.0(50 is the typical model of its size class)A-VHP09SA-1with ducted air handler B-VHP09DA-18 of 8 models have all five ratings · AHRI 217482458 |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class)A-VHP24SA-1with ducted air handler B-VHP24DA-17 of 14 models qualify · AHRI 217482470 | 78.6(50 is the typical model of its size class)A-VHP24SA-1with ducted air handler B-VHP24DA-112 of 12 models have all five ratings · AHRI 217482470 |
| Ducted, 2.5 to 3 tons | 82.7(50 is the typical model of its size class)A-VHP365A-14 of 13 models qualify · AHRI 218425166 | 83.9(50 is the typical model of its size class)A-VHP365A-113 of 13 models have all five ratings · AHRI 218425166 |
| Ducted, 3.5 to 4.5 tons | 82.6(50 is the typical model of its size class)A-VHP486A-18 of 21 models qualify · AHRI 218425169 | 84.3(50 is the typical model of its size class)A-VHP486A-122 of 22 models have all five ratings · AHRI 218425169 |
| Ducted, 5 tons and up | No models in this size class | 67.2(50 is the typical model of its size class)HSA1460S1-**Awith ducted air handler HMA60VX1*-1 of 1 models have all five ratings · AHRI 216370485 |
| Non-ducted, up to 1.5 tons | 97.0(50 is the typical model of its size class)A-VHP06SA-1with ductless indoor unit B-VHP06SA-16 of 6 models qualify · AHRI 218425153 | 96.6(50 is the typical model of its size class)A-VHP06SA-1with ductless indoor unit B-VHP06SA-16 of 6 models have all five ratings · AHRI 218425153 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class)A-VHP24SA-1with ductless indoor unit B-VHP24CA-11 of 1 models qualify · AHRI 217482468 | 78.3(50 is the typical model of its size class)A-VHP24SA-1with ductless indoor unit B-VHP24SA-11 of 1 models have all five ratings · AHRI 218425157 |
| Non-ducted, 2.5 to 3 tons | 78.3(50 is the typical model of its size class)A-VHP365A-13 of 3 models qualify · AHRI 218425167 | 78.8(50 is the typical model of its size class)A-VHP365A-13 of 3 models have all five ratings · AHRI 218425165 |
| Non-ducted, 3.5 to 4.5 tons | 73.6(50 is the typical model of its size class)A-VHP486A-12 of 2 models qualify · AHRI 218425170 | 75.4(50 is the typical model of its size class)A-VHP486A-12 of 2 models have all five ratings · AHRI 218425168 |
Newest Century certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| SHP1448S1ACENTURYwith ducted air handler V3642B-*EC*B**1 | 3 tons36,200 Btu/h · Ducted | 1.82 | 53% | 6.8 | 12.0 | None | 62 | 219136982 |
| SHP1442S1ACENTURYwith ducted air handler V3642B-*EC*B**1 | 2.5 tons32,600 Btu/h · Ducted | 1.86 | 53% | 6.1 | 12.0 | None | 33 | 219136980 |
| SHP1436S1ACENTURYwith ducted air handler V3642B-*EC*B**1 | 2.5 tons30,000 Btu/h · Ducted | 1.78 | 52% | 6.8 | 12.0 | None | 37 | 219136978 |
| SHP1430S1ACENTURYwith ducted air handler V2430B-*EC*E**1 | 2 tons24,200 Btu/h · Ducted | 1.74 | 48% | 6.8 | 12.0 | None | 60 | 219136974 |
| SHP1424S1ACENTURYwith ducted air handler M2430C*1-BA**1+M2430B**-EC | 1.5 tons18,800 Btu/h · Ducted | 1.62 | 49% | 6.8 | 12.0 | None | 33 | 219136967 |
Compare Century
Century includes these brand names as listed in AHRI: CENTURY. Standards are checked against published thresholds; program rules beyond ratings are not checked.