Comfort Temps heat pump efficiency: 20 outdoor models compared
Comfort Temps has 20 heat pump outdoor models certified with this refrigerant group, in 20 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Comfort Temps makes. Comfort Temps has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 20
- AHRI certifications
- 20
- Efficiency index
- 49%
- Typical model vs same-size, same-type peers (20 models)
- Meet CEE 2025
- 100%
- 20 models
How Comfort Temps compares with comparable models
- Comfort Temps
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index20 models scored | 49% | Not ranked | — |
| COP at 5°F20 models scored | 37% | Not ranked | 1.89 |
| Capacity retention at 5°F20 models scored | 38% | Not ranked | 72% |
| HSPF220 models scored | 53% | Not ranked | 9.5 |
| SEER220 models scored | 59% | Not ranked | 23.0 |
| EER220 models scored | 52% | Not ranked | 12.3 |
| Heating capacity at 5°F20 models scored | 41% | Not ranked | 9,100 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100% | 20 |
| CEE 2026 Tier 1 (Split ASHP) | 100% | 20 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 90% | 18 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 60% | 12 |
Sizes and duct types offered
- Comfort Temps (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 16 | 50% | 40% | 55% | 57% |
| Non-ducted, 2 tons | 4 | 45% | 27% | 44% | 65% |
Every Comfort Temps model in the market
- Comfort Temps models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Comfort Temps models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CTP-BH122A-OComfort Temps · T-PRO Serieswith ductless indoor unit CTP-BH122A-IAlso listed as CTP-BH122A-O | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 9,100 | 24.0 | CEE 25CEE 26XcelES CC | 1 | 216472852 | Non-ducted, up to 1.5 tons | 59.5 |
| 2CTP-BH121A-OComfort Temps · T-PRO Serieswith ductless indoor unit CTP-BH121A-IAlso listed as CTP-BH121A-O | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 8,900 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 216472850 | Non-ducted, up to 1.5 tons | 58.9 |
| 3CEL-BH092A-OComfort Tempswith ductless indoor unit CEL-BH092A-I | 1 ton9,000 Btu/h · Non-ducted | 74% | 1.90 | 10.0 | 7,400 | 20.0 | CEE 25CEE 26Xcel | 1 | 216472845 | Non-ducted, up to 1.5 tons | 50.4 |
| 4CTP-BH091A-OComfort Temps · T-PRO Serieswith ductless indoor unit CTP-BH091A-IAlso listed as CTP-BH091A-O | 1 ton9,000 Btu/h · Non-ducted | 75% | 1.89 | 9.5 | 7,500 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 216472849 | Non-ducted, up to 1.5 tons | 43.8 |
| 5CEL-BH091A-OComfort Tempswith ductless indoor unit CEL-BH091A-I | 1 ton9,000 Btu/h · Non-ducted | 73% | 1.89 | 9.5 | 7,300 | 19.0 | CEE 25CEE 26Xcel | 1 | 216472843 | Non-ducted, up to 1.5 tons | 40.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CTP-BH122A-OComfort Temps · T-PRO Serieswith ductless indoor unit CTP-BH122A-IAlso listed as CTP-BH122A-O | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 24.0 | 13.0 | CEE 25CEE 26XcelES CC | 1 | 216472852 | Non-ducted, up to 1.5 tons | 67.7 | 59.5 | 75.8 | 59.5 |
| 2CTP-BH121A-OComfort Temps · T-PRO Serieswith ductless indoor unit CTP-BH121A-IAlso listed as CTP-BH121A-O | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 23.0 | 13.0 | CEE 25CEE 26XcelES CC | 1 | 216472850 | Non-ducted, up to 1.5 tons | 65.0 | 58.9 | 71.1 | 58.9 |
| 3CTP-BH091A-OComfort Temps · T-PRO Serieswith ductless indoor unit CTP-BH091A-IAlso listed as CTP-BH091A-O | 1 ton9,000 Btu/h · Non-ducted | 75% | 1.89 | 9.5 | 23.0 | 13.0 | CEE 25CEE 26XcelES CC | 1 | 216472849 | Non-ducted, up to 1.5 tons | 57.4 | 43.8 | 71.1 | 43.8 |
| 4CTP-BH092A-OComfort Temps · T-PRO Serieswith ductless indoor unit CTP-BH092A-IAlso listed as CTP-BH092A-O | 1 ton9,000 Btu/h · Non-ducted | 71% | 1.89 | 9.5 | 23.0 | 13.0 | CEE 25CEE 26XcelES CC | 1 | 216472851 | Non-ducted, up to 1.5 tons | 54.4 | 37.8 | 71.1 | 37.8 |
| 5CTP-BH242A-OComfort Temps · T-PRO Serieswith ductless indoor unit CTP-BH242A-IAlso listed as CTP-BH242A-O | 2 tons23,000 Btu/h · Non-ducted | 76% | 1.80 | 9.5 | 23.0 | 12.0 | CEE 25CEE 26XcelES CC | 1 | 216472854 | Non-ducted, 2 tons | 52.8 | 37.7 | 68.0 | 37.7 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | CTP-BH121A-OAlso listed as CTP-BH121A-O | 2.10 | Non-ducted, up to 1.5 tons | 77% | 216472850 |
| Capacity retention at 5°F | CTP-BH242A-OAlso listed as CTP-BH242A-O | 76% | Non-ducted, 2 tons | 52% | 216472854 |
| HSPF2 | CEL-BH092A-O | 10.0 | Non-ducted, up to 1.5 tons | 64% | 216472845 |
| SEER2 | CTP-BH242A-OAlso listed as CTP-BH242A-O | 23.0 | Non-ducted, 2 tons | 79% | 216472854 |
| EER2 | CTP-BH091A-OAlso listed as CTP-BH091A-O | 13.0 | Non-ducted, up to 1.5 tons | 70% | 216472849 |
| Heating capacity at 5°F | CTP-BH182A-OAlso listed as CTP-BH182A-O | 13,600 Btu/h | Non-ducted, up to 1.5 tons | 79% | 216472853 |
Comfort Temps size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 59.5(50 is the typical model of its size class)CTP-BH122A-Owith ductless indoor unit CTP-BH122A-IAlso listed as CTP-BH122A-O15 of 16 models qualify · AHRI 216472852 | 67.7(50 is the typical model of its size class)CTP-BH122A-Owith ductless indoor unit CTP-BH122A-IAlso listed as CTP-BH122A-O16 of 16 models have all five ratings · AHRI 216472852 |
| Non-ducted, 2 tons | 37.7(50 is the typical model of its size class)CTP-BH242A-Owith ductless indoor unit CTP-BH242A-IAlso listed as CTP-BH242A-O3 of 4 models qualify · AHRI 216472854 | 52.8(50 is the typical model of its size class)CTP-BH242A-Owith ductless indoor unit CTP-BH242A-IAlso listed as CTP-BH242A-O4 of 4 models have all five ratings · AHRI 216472854 |
Newest Comfort Temps certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| CTP-BH242A-O*Comfort Temps · T-PRO Serieswith ductless indoor unit CTP-BH242A-I | 2 tons23,000 Btu/h · Non-ducted | 1.80 | 76% | 9.5 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 218003263 |
| CTP-BH182A-O*Comfort Temps · T-PRO Serieswith ductless indoor unit CTP-BH182A-I | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 72% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 218003262 |
| CTP-BH122A-O*Comfort Temps · T-PRO Serieswith ductless indoor unit CTP-BH122A-I | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 72% | 10.0 | 24.0 | CEE 25CEE 26XcelES CC | 1 | 218003261 |
| CTP-BH092A-O*Comfort Temps · T-PRO Serieswith ductless indoor unit CTP-BH092A-I | 1 ton9,000 Btu/h · Non-ducted | 1.89 | 71% | 9.5 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 218003260 |
| CTP-BH121A-O*Comfort Temps · T-PRO Serieswith ductless indoor unit CTP-BH121A-I | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 72% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 218003259 |
Compare Comfort Temps
Comfort Temps includes these brand names as listed in AHRI: Comfort Temps. Standards are checked against published thresholds; program rules beyond ratings are not checked.