Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
DIAL heat pump efficiency: 7 outdoor models compared
DIAL has 7 heat pump outdoor models certified with this refrigerant group, in 7 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes DIAL makes. DIAL has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 7
- AHRI certifications
- 7
- Efficiency index
- 58%
- Typical model vs same-size, same-type peers (7 models)
- Meet CEE 2025
- 100%
- 7 models
How DIAL compares with comparable models
- DIAL
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index7 models scored | 58% | Not ranked | — |
| COP at 5°F7 models scored | 48% | Not ranked | 2.00 |
| Capacity retention at 5°F7 models scored | 38% | Not ranked | 72% |
| HSPF27 models scored | 61% | Not ranked | 10.0 |
| SEER27 models scored | 75% | Not ranked | 23.0 |
| EER27 models scored | 57% | Not ranked | 12.5 |
| Heating capacity at 5°F7 models scored | 42% | Not ranked | 13,600 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100% | 7 |
| CEE 2026 Tier 1 (Split ASHP) | 100% | 7 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100% | 7 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- DIAL (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 4 | 60% | 54% | 61% | 72% |
| Non-ducted, 2 tons | 1 | 48% | 17% | 44% | 82% |
| Non-ducted, 2.5–3 tons | 2 | 58% | 53% | 70% | 79% |
Every DIAL model in the market
- DIAL models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top DIAL models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1A2LSZHW12WW230BDJDIAL · T-PROwith ductless indoor unit A2LSZHW12NN230BDJ | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 9,100 | 24.0 | CEE 25CEE 26Xcel | 1 | 217730605 | Non-ducted, up to 1.5 tons | 59.5 |
| 2A2LSZHW12WW115BCJDIAL · T-PROwith ductless indoor unit A2LSZHW12NN115BCJ | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 8,900 | 23.0 | CEE 25CEE 26Xcel | 1 | 217730604 | Non-ducted, up to 1.5 tons | 58.9 |
| 3A2LMZ27WW3PBDJDIAL · T-PRO | 2.5 tons27,000 Btu/h · Non-ducted | 71% | 2.00 | 10.5 | 19,800 | 24.0 | CEE 25CEE 26Xcel | 1 | 217730608 | Non-ducted, 2.5–3 tons | 57.5 |
| 4A2LMZ35WW4PBBEDIAL · T-PRO | 3 tons35,000 Btu/h · Non-ducted | 72% | 2.00 | 10.0 | 26,000 | 22.5 | CEE 25CEE 26Xcel | 1 | 217730609 | Non-ducted, 2.5–3 tons | 52.5 |
| 5A2LSZHW09WW115BDJDIAL · T-PROwith ductless indoor unit A2LSZHW09NN115BDJ | 1 ton9,000 Btu/h · Non-ducted | 71% | 1.90 | 9.5 | 7,100 | 23.0 | CEE 25CEE 26Xcel | 1 | 217730603 | Non-ducted, up to 1.5 tons | 39.5 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1A2LSZHW12WW230BDJDIAL · T-PROwith ductless indoor unit A2LSZHW12NN230BDJ | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 24.0 | 13.0 | CEE 25CEE 26Xcel | 1 | 217730605 | Non-ducted, up to 1.5 tons | 67.7 | 59.5 | 75.8 | 59.5 |
| 2A2LMZ27WW3PBDJDIAL · T-PRO | 2.5 tons27,000 Btu/h · Non-ducted | 71% | 2.00 | 10.5 | 24.0 | 12.0 | CEE 25CEE 26Xcel | 1 | 217730608 | Non-ducted, 2.5–3 tons | 65.1 | 57.5 | 72.6 | 57.5 |
| 3A2LSZHW12WW115BCJDIAL · T-PROwith ductless indoor unit A2LSZHW12NN115BCJ | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 23.0 | 13.0 | CEE 25CEE 26Xcel | 1 | 217730604 | Non-ducted, up to 1.5 tons | 65.0 | 58.9 | 71.1 | 58.9 |
| 4A2LSZHW09WW115BDJDIAL · T-PROwith ductless indoor unit A2LSZHW09NN115BDJ | 1 ton9,000 Btu/h · Non-ducted | 71% | 1.90 | 9.5 | 23.0 | 13.0 | CEE 25CEE 26Xcel | 1 | 217730603 | Non-ducted, up to 1.5 tons | 55.3 | 39.5 | 71.1 | 39.5 |
| 5A2LSZHW18WW230BCJDIAL · T-PROwith ductless indoor unit A2LSZHW18NN230BCJ | 1.5 tons18,000 Btu/h · Non-ducted | 72% | 1.80 | 10.0 | 23.0 | 12.5 | CEE 25CEE 26Xcel | 1 | 217730606 | Non-ducted, up to 1.5 tons | 51.5 | 39.1 | 63.8 | 39.1 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | A2LSZHW12WW115BCJ | 2.10 | Non-ducted, up to 1.5 tons | 77% | 217730604 |
| Capacity retention at 5°F | A2LSZHW23WW230BCJ | 74% | Non-ducted, 2 tons | 49% | 217730607 |
| HSPF2 | A2LMZ27WW3PBDJ | 10.5 | Non-ducted, 2.5–3 tons | 80% | 217730608 |
| SEER2 | A2LMZ27WW3PBDJ | 24.0 | Non-ducted, 2.5–3 tons | 91% | 217730608 |
| EER2 | A2LSZHW09WW115BDJ | 13.0 | Non-ducted, up to 1.5 tons | 70% | 217730603 |
| Heating capacity at 5°F | A2LSZHW18WW230BCJ | 13,600 Btu/h | Non-ducted, up to 1.5 tons | 79% | 217730606 |
DIAL size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 59.5(50 is the typical model of its size class)A2LSZHW12WW230BDJwith ductless indoor unit A2LSZHW12NN230BDJ4 of 4 models qualify · AHRI 217730605 | 67.7(50 is the typical model of its size class)A2LSZHW12WW230BDJwith ductless indoor unit A2LSZHW12NN230BDJ4 of 4 models have all five ratings · AHRI 217730605 |
| Non-ducted, 2 tons | 36.7(50 is the typical model of its size class)A2LSZHW23WW230BCJwith ductless indoor unit A2LSZHW23NN230BCJ1 of 1 models qualify · AHRI 217730607 | 48.3(50 is the typical model of its size class)A2LSZHW23WW230BCJwith ductless indoor unit A2LSZHW23NN230BCJ1 of 1 models have all five ratings · AHRI 217730607 |
| Non-ducted, 2.5–3 tons | 57.5(50 is the typical model of its size class)A2LMZ27WW3PBDJ2 of 2 models qualify · AHRI 217730608 | 65.1(50 is the typical model of its size class)A2LMZ27WW3PBDJ2 of 2 models have all five ratings · AHRI 217730608 |
Newest DIAL certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| A2LMZ35WW4PBBEDIAL · T-PRO | 3 tons35,000 Btu/h · Non-ducted | 2.00 | 72% | 10.0 | 22.5 | CEE 25CEE 26Xcel | 1 | 217730609 |
| A2LMZ27WW3PBDJDIAL · T-PRO | 2.5 tons27,000 Btu/h · Non-ducted | 2.00 | 71% | 10.5 | 24.0 | CEE 25CEE 26Xcel | 1 | 217730608 |
| A2LSZHW23WW230BCJDIAL · T-PROwith ductless indoor unit A2LSZHW23NN230BCJ | 2 tons23,000 Btu/h · Non-ducted | 1.80 | 74% | 9.5 | 23.0 | CEE 25CEE 26Xcel | 1 | 217730607 |
| A2LSZHW18WW230BCJDIAL · T-PROwith ductless indoor unit A2LSZHW18NN230BCJ | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 72% | 10.0 | 23.0 | CEE 25CEE 26Xcel | 1 | 217730606 |
| A2LSZHW12WW230BDJDIAL · T-PROwith ductless indoor unit A2LSZHW12NN230BDJ | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 72% | 10.0 | 24.0 | CEE 25CEE 26Xcel | 1 | 217730605 |
Compare DIAL
DIAL includes these brand names as listed in AHRI: DIAL. Standards are checked against published thresholds; program rules beyond ratings are not checked.