Skip to content

AIRTEMP vs Dial heat pumps

Measured against models of the same size and duct type, Dial scores higher on 6 of the 6 ratings. AIRTEMP has 47 outdoor models, Dial has 46 outdoor models. AIRTEMP and Dial have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AIRTEMP and Dial on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Dial scores higher on 6 of the 6 ratings.
  • AIRTEMP
  • Dial
  • Other ranked manufacturers
AIRTEMPDial

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAIRTEMPDial
Efficiency index36%median —55%median —
COP at 5°F26%median 1.7555%median 2.00
Capacity retention at 5°F37%median 51%54%median 71%
HSPF230%median 7.563%median 9.5
SEER235%median 14.358%median 19.7
EER246%median 11.048%median 11.7
Heating capacity at 5°F36%median 16,200 Btu/h59%median 18,000 Btu/h
Outdoor models4746
AHRI certifications15390

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAIRTEMPDial
CEE 2025 Tier 1 (Split ASHP)42.6%20 models73.9%34 models
CEE 2026 Tier 1 (Split ASHP)40.4%19 models71.7%33 models
CEE Advanced Tier (Split ASHP)4.3%2 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)40.4%19 models69.6%32 models
DOE Cold Climate Heat Pump Challenge4.3%2 models0%0 models
ENERGY STAR Cold Climate25.5%12 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • AIRTEMP
  • Dial
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAIRTEMPDial
Ducted, up to 1.5 tons2 · index 31%6 · index 67%
Ducted, 2 tons7 · index 30%4 · index 58%
Ducted, 2.5 to 3 tons12 · index 28%7 · index 64%
Ducted, 3.5 to 4.5 tons13 · index 29%6 · index 57%
Ducted, 5 tons and up1 · index 18%1 · index 63%
Non-ducted, up to 1.5 tons9 · index 47%20 · index 50%
Non-ducted, 2 tons3 · index 56%5 · index 47%
Non-ducted, 2.5 to 3 tons4 · index 53%6 · index 56%
Non-ducted, 3.5 to 4.5 tons1 · index 68%2 · index 57%
Non-ducted, 5 tons and upNone1 · index 27%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAIRTEMPCold-climate score, best modelDialCold-climate score, best model
Ducted, up to 1.5 tons40.5(50 is the typical model of its size class)DXH18FMK3IH1 of 2 models qualify · AHRI 21574630080.4(50 is the typical model of its size class) (higher)DAP181H2A1with ducted air handler DAP18M2A15 of 6 models qualify · AHRI 218828355
Ducted, 2 tons48.9(50 is the typical model of its size class)DXH24FMK3IH1 of 6 models qualify · AHRI 21574630285.8(50 is the typical model of its size class) (higher)DAP241H2A1with ducted air handler DAP24D2A14 of 4 models qualify · AHRI 218828311
Ducted, 2.5 to 3 tons77.3(50 is the typical model of its size class)UXH24-36MSK3IHwith ducted air handler UMD36MSK3IH4 of 13 models qualify · AHRI 21713820382.7(50 is the typical model of its size class) (higher)DAP365H2A16 of 7 models qualify · AHRI 218828334
Ducted, 3.5 to 4.5 tons83.9(50 is the typical model of its size class) (higher)UXH48-60MSK3IHwith ducted air handler UMD60MSK3IH1 of 13 models qualify · AHRI 21713820582.6(50 is the typical model of its size class)DAP486H2A16 of 6 models qualify · AHRI 218828337
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons63.8(50 is the typical model of its size class)DXH09PSK3IHwith ductless indoor unit DHH09PUK3IH9 of 9 models qualify · AHRI 21601175579.8(50 is the typical model of its size class) (higher)DAP121H2A1with ductless indoor unit DAP12C2A113 of 20 models qualify · AHRI 218828303
Non-ducted, 2 tons68.5(50 is the typical model of its size class)DXH24FMK3IH3 of 3 models qualify · AHRI 21574629690.1(50 is the typical model of its size class) (higher)DAP241H2A1with ductless indoor unit DAP24C2A15 of 5 models qualify · AHRI 218828310
Non-ducted, 2.5 to 3 tons77.8(50 is the typical model of its size class) (higher)DXH36FMK3IH4 of 4 models qualify · AHRI 21574629872.8(50 is the typical model of its size class)DAP365H2A16 of 6 models qualify · AHRI 218828335
Non-ducted, 3.5 to 4.5 tons67.0(50 is the typical model of its size class)DXH42FMK3IH1 of 1 models qualify · AHRI 21574629969.0(50 is the typical model of its size class) (higher)DAP486H2A12 of 2 models qualify · AHRI 218828338
Non-ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAIRTEMPAll-around score, best modelDialAll-around score, best model
Ducted, up to 1.5 tons41.2(50 is the typical model of its size class)DXH18FMK3IH2 of 2 models have all five ratings · AHRI 21574630077.9(50 is the typical model of its size class) (higher)DAP183H2A16 of 6 models have all five ratings · AHRI 218828328
Ducted, 2 tons55.0(50 is the typical model of its size class)DXH24FMK3IH6 of 6 models have all five ratings · AHRI 21574630278.6(50 is the typical model of its size class) (higher)DAP241H2A1with ducted air handler DAP24D2A14 of 4 models have all five ratings · AHRI 218828311
Ducted, 2.5 to 3 tons68.5(50 is the typical model of its size class)UXH24-36MSK3IHwith ducted air handler UMD36MSK3IH13 of 13 models have all five ratings · AHRI 21713820383.9(50 is the typical model of its size class) (higher)DAP365H2A17 of 7 models have all five ratings · AHRI 218828334
Ducted, 3.5 to 4.5 tons80.0(50 is the typical model of its size class)UXH48-60MSK3IHwith ducted air handler UMD48MSK3IH13 of 13 models have all five ratings · AHRI 21713820485.3(50 is the typical model of its size class) (higher)DAS486H2A16 of 6 models have all five ratings · AHRI 218828322
Ducted, 5 tons and up17.7(50 is the typical model of its size class)RHPXYB060AJT1 of 1 models have all five ratings · AHRI 21760814363.2(50 is the typical model of its size class) (higher)DAS606H2A11 of 1 models have all five ratings · AHRI 218828325
Non-ducted, up to 1.5 tons79.1(50 is the typical model of its size class)DXH09PSK3IHwith ductless indoor unit DHH09PUK3IH9 of 9 models have all five ratings · AHRI 21601175584.4(50 is the typical model of its size class) (higher)DAP091H2A1with ductless indoor unit DAP09V2A120 of 20 models have all five ratings · AHRI 218828302
Non-ducted, 2 tons73.1(50 is the typical model of its size class)DXH24PSK3IHwith ductless indoor unit DHH24PUK3IH3 of 3 models have all five ratings · AHRI 21601175974.3(50 is the typical model of its size class) (higher)DAP241H2A1with ductless indoor unit DAP24W2A15 of 5 models have all five ratings · AHRI 218828298
Non-ducted, 2.5 to 3 tons71.2(50 is the typical model of its size class) (higher)DXH30FMK3IH4 of 4 models have all five ratings · AHRI 21574629767.0(50 is the typical model of its size class)DAP365H2A16 of 6 models have all five ratings · AHRI 218828333
Non-ducted, 3.5 to 4.5 tons67.8(50 is the typical model of its size class) (higher)DXH42FMK3IH1 of 1 models have all five ratings · AHRI 21574629962.4(50 is the typical model of its size class)DAP486H2A12 of 2 models have all five ratings · AHRI 218828336
Non-ducted, 5 tons and upNo models in this size class32.9(50 is the typical model of its size class)DAS606H2A11 of 1 models have all five ratings · AHRI 218828324

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAIRTEMPDial
COP at 5°Fbeats 87% · 2.10DXH36FMK3IHNon-ducted, 2.5 to 3 tonsbeats 90% · 2.25DAS183H2A1Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 99% · 114%UXH48-60MSK3IHDucted, 3.5 to 4.5 tonsbeats 98% · 126%DAP091H2A1Non-ducted, up to 1.5 tons
HSPF2beats 87% · 10.0UXH48-60MSK3IHDucted, 3.5 to 4.5 tonsbeats 99% · 11.0DAP486H2A1Ducted, 3.5 to 4.5 tons
SEER2beats 97% · 26.0DXH24PSK3IHNon-ducted, 2 tonsbeats 96% · 20.4DAS486H2A1Ducted, 3.5 to 4.5 tons
EER2beats 95% · 13.0DXH42FMK3IHNon-ducted, 3.5 to 4.5 tonsbeats 94% · 15.1DAP091H2A1Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 54,000 Btu/hUXH48-60MSK3IHDucted, 3.5 to 4.5 tonsbeats 98% · 39,000 Btu/hDSP361H2A1Ducted, 2.5 to 3 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter