AIRTEMP vs Pioneer heat pumps

Measured against models of the same size and duct type, Pioneer scores higher on 5 of the 6 ratings. AIRTEMP has 47 outdoor models, Pioneer has 46 outdoor models. AIRTEMP has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AIRTEMP and Pioneer on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Pioneer scores higher on 5 of the 6 ratings.
  • AIRTEMP
  • Pioneer
  • Other ranked manufacturers
AIRTEMPPioneer

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAIRTEMPPioneer
Efficiency index36%median —48%median — · 24th ranked
COP at 5°F26%median 1.7542%median 1.88 · 27th ranked
Capacity retention at 5°F37%median 51%44%median 73% · 22nd ranked
HSPF230%median 7.558%median 9.5 · 10th ranked
SEER235%median 14.357%median 20.0 · 11th ranked
EER246% (higher)median 11.040% (higher)median 11.2 · 25th ranked
Heating capacity at 5°F36%median 16,200 Btu/h46%median 12,800 Btu/h · 22nd ranked
Outdoor models4746
AHRI certifications15369

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAIRTEMPPioneer
CEE 2025 Tier 1 (Split ASHP)42.6%20 models73.9%34 models
CEE 2026 Tier 1 (Split ASHP)40.4%19 models73.9%34 models
CEE Advanced Tier (Split ASHP)4.3%2 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)40.4%19 models69.6%32 models
DOE Cold Climate Heat Pump Challenge4.3%2 models0%0 models
ENERGY STAR Cold Climate25.5%12 models54.3%25 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • AIRTEMP
  • Pioneer
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAIRTEMPPioneer
Ducted, up to 1.5 tons2 · index 31%4 · index 55%
Ducted, 2 tons7 · index 30%2 · index 68%
Ducted, 2.5 to 3 tons12 · index 28%4 · index 56%
Ducted, 3.5 to 4.5 tons13 · index 29%4 · index 59%
Ducted, 5 tons and up1 · index 18%1 · index 71%
Non-ducted, up to 1.5 tons9 · index 47%26 · index 50%
Non-ducted, 2 tons3 · index 56%5 · index 38%
Non-ducted, 2.5 to 3 tons4 · index 53%8 · index 32%
Non-ducted, 3.5 to 4.5 tons1 · index 68%3 · index 38%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAIRTEMPCold-climate score, best modelPioneerCold-climate score, best model
Ducted, up to 1.5 tons40.5(50 is the typical model of its size class)DXH18FMK3IH1 of 2 models qualify · AHRI 21574630059.4(50 is the typical model of its size class) (higher)YN009GLSI24RPG4 of 4 models qualify · AHRI 217048762
Ducted, 2 tons48.9(50 is the typical model of its size class)DXH24FMK3IH1 of 6 models qualify · AHRI 21574630266.8(50 is the typical model of its size class) (higher)YD2436GCSI18RDwith ducted air handler DC024GCSICDHRT2 of 2 models qualify · AHRI 217048497
Ducted, 2.5 to 3 tons77.3(50 is the typical model of its size class) (higher)UXH24-36MSK3IHwith ducted air handler UMD36MSK3IH4 of 13 models qualify · AHRI 21713820362.1(50 is the typical model of its size class)YN040GLSI24M4G2 of 4 models qualify · AHRI 217048774
Ducted, 3.5 to 4.5 tons83.9(50 is the typical model of its size class) (higher)UXH48-60MSK3IHwith ducted air handler UMD60MSK3IH1 of 13 models qualify · AHRI 21713820567.8(50 is the typical model of its size class)YN048GMSI20RUGwith ducted air handler RB048GMSILDFHG4 of 4 models qualify · AHRI 218010994
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)64.2(50 is the typical model of its size class)PRD-60HWD1N10-M18G1 of 1 models qualify · AHRI 216684003
Non-ducted, up to 1.5 tons63.8(50 is the typical model of its size class)DXH09PSK3IHwith ductless indoor unit DHH09PUK3IH9 of 9 models qualify · AHRI 21601175579.7(50 is the typical model of its size class) (higher)YN018GMSI24RPGwith ductless indoor unit FB018GMSILDFHG21 of 26 models qualify · AHRI 218010990
Non-ducted, 2 tons68.5(50 is the typical model of its size class) (higher)DXH24FMK3IH3 of 3 models qualify · AHRI 21574629660.1(50 is the typical model of its size class)YN024GLSI24RPGwith ductless indoor unit CT024GLSILCFHG2 of 5 models qualify · AHRI 217048761
Non-ducted, 2.5 to 3 tons77.8(50 is the typical model of its size class) (higher)DXH36FMK3IH4 of 4 models qualify · AHRI 21574629863.6(50 is the typical model of its size class)YN036GMSI20RUGwith ductless indoor unit CB036GMSILDFHG3 of 8 models qualify · AHRI 218010991
Non-ducted, 3.5 to 4.5 tons67.0(50 is the typical model of its size class) (higher)DXH42FMK3IH1 of 1 models qualify · AHRI 21574629955.8(50 is the typical model of its size class)YN048GMSI20RUGwith ductless indoor unit CB048GMSILDFHG3 of 3 models qualify · AHRI 218010992

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAIRTEMPAll-around score, best modelPioneerAll-around score, best model
Ducted, up to 1.5 tons41.2(50 is the typical model of its size class)DXH18FMK3IH2 of 2 models have all five ratings · AHRI 21574630065.8(50 is the typical model of its size class) (higher)YN009GLSI24RPG4 of 4 models have all five ratings · AHRI 217048762
Ducted, 2 tons55.0(50 is the typical model of its size class)DXH24FMK3IH6 of 6 models have all five ratings · AHRI 21574630279.5(50 is the typical model of its size class) (higher)YD2436GCSI18RDwith ducted air handler DC024GCSICDHRT2 of 2 models have all five ratings · AHRI 217048497
Ducted, 2.5 to 3 tons68.5(50 is the typical model of its size class) (higher)UXH24-36MSK3IHwith ducted air handler UMD36MSK3IH13 of 13 models have all five ratings · AHRI 21713820364.1(50 is the typical model of its size class)YN040GLSI24M4G4 of 4 models have all five ratings · AHRI 217048774
Ducted, 3.5 to 4.5 tons80.0(50 is the typical model of its size class) (higher)UXH48-60MSK3IHwith ducted air handler UMD48MSK3IH13 of 13 models have all five ratings · AHRI 21713820465.3(50 is the typical model of its size class)YD4860GCSI18RDwith ducted air handler DC048GCSICDHRT4 of 4 models have all five ratings · AHRI 217048499
Ducted, 5 tons and up17.7(50 is the typical model of its size class)RHPXYB060AJT1 of 1 models have all five ratings · AHRI 21760814370.5(50 is the typical model of its size class) (higher)PRD-60HWD1N10-M18G1 of 1 models have all five ratings · AHRI 216684003
Non-ducted, up to 1.5 tons79.1(50 is the typical model of its size class) (higher)DXH09PSK3IHwith ductless indoor unit DHH09PUK3IH9 of 9 models have all five ratings · AHRI 21601175577.5(50 is the typical model of its size class)YN012GMSI24RPGwith ductless indoor unit FB012GMSILDFHG26 of 26 models have all five ratings · AHRI 218010989
Non-ducted, 2 tons73.1(50 is the typical model of its size class) (higher)DXH24PSK3IHwith ductless indoor unit DHH24PUK3IH3 of 3 models have all five ratings · AHRI 21601175958.9(50 is the typical model of its size class)YN024GLSI24RPGwith ductless indoor unit CT024GLSILCFHG5 of 5 models have all five ratings · AHRI 217048761
Non-ducted, 2.5 to 3 tons71.2(50 is the typical model of its size class) (higher)DXH30FMK3IH4 of 4 models have all five ratings · AHRI 21574629765.9(50 is the typical model of its size class)YN030GLSI24M3G8 of 8 models have all five ratings · AHRI 217048769
Non-ducted, 3.5 to 4.5 tons67.8(50 is the typical model of its size class) (higher)DXH42FMK3IH1 of 1 models have all five ratings · AHRI 21574629942.3(50 is the typical model of its size class)YN050GLSI24M5G3 of 3 models have all five ratings · AHRI 217048771

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAIRTEMPPioneer
COP at 5°Fbeats 87% · 2.10DXH36FMK3IHNon-ducted, 2.5 to 3 tonsbeats 99% · 2.51YN012GMSI24RPGNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 99% · 114%UXH48-60MSK3IHDucted, 3.5 to 4.5 tonsbeats 93% · 106%YN009GLSI25RPHNon-ducted, up to 1.5 tons
HSPF2beats 87% · 10.0UXH48-60MSK3IHDucted, 3.5 to 4.5 tonsbeats 97% · 13.5YN018GMSI24RPGNon-ducted, up to 1.5 tons
SEER2beats 97% · 26.0DXH24PSK3IHNon-ducted, 2 tonsbeats 98% · 21.0YN030GLSI24M3GDucted, 2.5 to 3 tons
EER2beats 95% · 13.0DXH42FMK3IHNon-ducted, 3.5 to 4.5 tonsbeats 93% · 13.3YD2436GCSI18RDDucted, 2 tons
Heating capacity at 5°Fbeats 98% · 54,000 Btu/hUXH48-60MSK3IHDucted, 3.5 to 4.5 tonsbeats 91% · 17,800 Btu/hYN018GLSI25RPHNon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
AIRTEMP vs Pioneer: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • AIRTEMP (median, middle 50%)
  • Pioneer (median, middle 50%)
Heating capacity, % of its 47°F maximum70%66%COP at maximum capacity1.942.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
AIRTEMP: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
AIRTEMP, 47°F19100%100%100%100%100%
AIRTEMP, 17°F1968%77%84%88%97%
AIRTEMP, 5°F1956%60%70%80%90%
AIRTEMP: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
AIRTEMP, 47°F192.863.183.233.323.51
AIRTEMP, 17°F1922.092.252.382.6
AIRTEMP, 5°F191.81.811.9422.1
Pioneer: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Pioneer, 47°F33100%100%100%100%100%
Pioneer, 17°F3366%69%73%76%83%
Pioneer, 5°F3357%60%66%70%73%
Pioneer: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Pioneer, 47°F332.843.143.333.513.66
Pioneer, 17°F332.042.12.22.272.49
Pioneer, 5°F331.81.8422.12.16

Source: NEEP ccASHP list · as of