Generallux heat pump efficiency: 17 outdoor models compared
Generallux has 17 heat pump outdoor models certified with this refrigerant group, in 23 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Generallux makes. Generallux has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 17
- AHRI certifications
- 23
- Efficiency index
- 47%
- Typical model vs same-size, same-type peers (20 models)
- Meet CEE 2025
- 76.5%
- 13 models
How Generallux compares with comparable models
- Generallux
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index20 models scored | 47% | Not ranked | — |
| COP at 5°F20 models scored | 39% | Not ranked | 1.90 |
| Capacity retention at 5°F20 models scored | 41% | Not ranked | 72% |
| HSPF220 models scored | 58% | Not ranked | 10.0 |
| SEER220 models scored | 59% | Not ranked | 22.5 |
| EER220 models scored | 39% | Not ranked | 11.2 |
| Heating capacity at 5°F20 models scored | 51% | Not ranked | 13,600 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 76.5% | 13 |
| CEE 2026 Tier 1 (Split ASHP) | 76.5% | 13 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 70.6% | 12 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- Generallux (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 2 | 50% | 37% | 52% | 79% |
| Ducted, 2 tons | 1 | 56% | 51% | 85% | 76% |
| Non-ducted, up to 1.5 tons | 10 | 49% | 36% | 57% | 55% |
| Non-ducted, 2 tons | 3 | 42% | 24% | 65% | 48% |
| Non-ducted, 2.5–3 tons | 3 | 46% | 63% | 54% | 57% |
| Non-ducted, 3.5–4.5 tons | 1 | 42% | 37% | 40% | 73% |
Every Generallux model in the market
- Generallux models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Generallux models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TFM2G18CHAIR454BGenerallux | 1.5 tons18,000 Btu/h · Non-ducted | 80% | 2.00 | 10.5 | 16,000 | 24.0 | CEE 25CEE 26Xcel | 1 | 216765715 | Non-ducted, up to 1.5 tons | 68.6 |
| 2THH12E2S25NAR454OGeneralluxwith ductless indoor unit THH12E2S25NAR454I | 1 ton12,000 Btu/h · Non-ducted | 100% | 1.80 | 10.5 | 12,000 | 25.0 | CEE 25CEE 26Xcel | 1 | 216765712 | Non-ducted, up to 1.5 tons | 62.1 |
| 3TSHG24E2S20NAR45OGenerallux | 2 tons22,000 Btu/h · Ducted | 74% | 2.00 | 10.0 | 18,500 | 19.0 | CEE 25CEE 26Xcel | 3 | 216765727 | Ducted, 2 tons | 60.1 |
| 4TSHG12E2M23NAR45OGeneralluxwith ductless indoor unit TSHG12E2M23NAR45I | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 9,100 | 24.0 | CEE 25CEE 26Xcel | 3 | 216765709 | Non-ducted, up to 1.5 tons | 59.5 |
| 5TSHG12E1O22NAR45OGeneralluxwith ductless indoor unit TSHG12E1O22NAR45I | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 8,900 | 23.0 | CEE 25CEE 26Xcel | 1 | 216765708 | Non-ducted, up to 1.5 tons | 58.9 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1THH12E2S25NAR454OGeneralluxwith ductless indoor unit THH12E2S25NAR454I | 1 ton12,000 Btu/h · Non-ducted | 100% | 1.80 | 10.5 | 25.0 | 14.0 | CEE 25CEE 26Xcel | 1 | 216765712 | Non-ducted, up to 1.5 tons | 74.4 | 62.1 | 86.7 | 62.1 |
| 2TFM2G18CHAIR454BGenerallux | 1.5 tons18,000 Btu/h · Non-ducted | 80% | 2.00 | 10.5 | 24.0 | 13.0 | CEE 25CEE 26Xcel | 1 | 216765715 | Non-ducted, up to 1.5 tons | 72.2 | 68.6 | 75.8 | 68.6 |
| 3TSHG12E2M23NAR45OGeneralluxwith ductless indoor unit TSHG12E2M23NAR45I | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 24.0 | 13.0 | CEE 25CEE 26Xcel | 3 | 216765709 | Non-ducted, up to 1.5 tons | 67.7 | 59.5 | 75.8 | 59.5 |
| 4TFM3G27CHAIR454BGenerallux | 2.5 tons27,000 Btu/h · Non-ducted | 71% | 2.00 | 10.5 | 24.0 | 12.0 | CEE 25CEE 26Xcel | 1 | 216765716 | Non-ducted, 2.5–3 tons | 65.1 | 57.5 | 72.6 | 57.5 |
| 5TSHG12E1O22NAR45OGeneralluxwith ductless indoor unit TSHG12E1O22NAR45I | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 23.0 | 13.0 | CEE 25CEE 26Xcel | 1 | 216765708 | Non-ducted, up to 1.5 tons | 65.0 | 58.9 | 71.1 | 58.9 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | TSHG36E2S19NAR45O | 2.03 | Non-ducted, 2.5–3 tons | 81% | 216765707 |
| Capacity retention at 5°F | THH12E2S25NAR454O | 100% | Non-ducted, up to 1.5 tons | 87% | 216765712 |
| HSPF2 | TSHG24E2S20NAR45O | 10.4 | Non-ducted, 2 tons | 81% | 216765724 |
| SEER2 | TFM3G27CHAIR454B | 24.0 | Non-ducted, 2.5–3 tons | 91% | 216765716 |
| EER2 | THH12E2S25NAR454O | 14.0 | Non-ducted, up to 1.5 tons | 83% | 216765712 |
| Heating capacity at 5°F | THH18E2S24NAR454O | 17,800 Btu/h | Non-ducted, up to 1.5 tons | 90% | 216765713 |
Generallux size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 54.1(50 is the typical model of its size class)TSHG18E2S22NAR45O2 of 2 models qualify · AHRI 216765726 | 57.0(50 is the typical model of its size class)TSHG18E2S22NAR45O2 of 2 models have all five ratings · AHRI 216765726 |
| Ducted, 2 tons | 60.1(50 is the typical model of its size class)TSHG24E2S20NAR45O1 of 1 models qualify · AHRI 216765727 | 55.8(50 is the typical model of its size class)TSHG24E2S20NAR45O1 of 1 models have all five ratings · AHRI 216765727 |
| Non-ducted, up to 1.5 tons | 68.6(50 is the typical model of its size class)TFM2G18CHAIR454B7 of 10 models qualify · AHRI 216765715 | 74.4(50 is the typical model of its size class)THH12E2S25NAR454Owith ductless indoor unit THH12E2S25NAR454I10 of 10 models have all five ratings · AHRI 216765712 |
| Non-ducted, 2 tons | 58.8(50 is the typical model of its size class)TSHG24E2S20NAR45Owith ductless indoor unit TSCAS24CD2VIR45I2 of 3 models qualify · AHRI 216765724 | 56.5(50 is the typical model of its size class)TSHG24E2S20NAR45Owith ductless indoor unit TSCAS24CD2VIR45I3 of 3 models have all five ratings · AHRI 216765724 |
| Non-ducted, 2.5–3 tons | 57.5(50 is the typical model of its size class)TFM3G27CHAIR454B2 of 3 models qualify · AHRI 216765716 | 65.1(50 is the typical model of its size class)TFM3G27CHAIR454B3 of 3 models have all five ratings · AHRI 216765716 |
| Non-ducted, 3.5–4.5 tons | 31.2(50 is the typical model of its size class)TFM5G42CHAIR454B1 of 1 models qualify · AHRI 216765718 | 42.4(50 is the typical model of its size class)TFM5G42CHAIR454B1 of 1 models have all five ratings · AHRI 216765718 |
Newest Generallux certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| TSHG24E2S20NAR45OGenerallux | 2 tons22,000 Btu/h · Ducted and non-ducted | 2.00 | 74% | 10.0 | 19.0 | CEE 25CEE 26Xcel | 3 | 216765727 |
| TSHG18E2S22NAR45OGenerallux | 1.5 tons17,000 Btu/h · Ducted and non-ducted | 1.80 | 73% | 10.0 | 20.3 | CEE 25CEE 26Xcel | 3 | 216765726 |
| TSHG12E2M23NAR45OGenerallux | 1 ton11,000 Btu/h · Ducted and non-ducted | 1.80 | 73% | 8.4 | 19.0 | CEE 25CEE 26Xcel | 3 | 216765725 |
| TAC24CHSAG2R32O18Generalluxwith ductless indoor unit TAC24CHSAG2R32I18 | 2 tons23,000 Btu/h · Non-ducted | 1.80 | 54% | 9.5 | 17.0 | None | 1 | 216765721 |
| TAC18CHSAG2R32O18Generalluxwith ductless indoor unit TAC18CHSAG2R32I18 | 1.5 tons17,000 Btu/h · Non-ducted | 1.80 | 58% | 8.5 | 17.0 | None | 1 | 216765720 |
Compare Generallux