Skip to content

Generallux heat pump efficiency: 17 outdoor models compared

Generallux has 17 heat pump outdoor models certified with this refrigerant group, in 23 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Generallux makes. Generallux has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
17
AHRI certifications
23
Efficiency index
47%
Typical model vs same-size, same-type peers (20 models)
Meet CEE 2025
76.5%
13 models

How Generallux compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Generallux against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of Generallux’s own modelsGenerallux is strongest on SEER2 (its typical model beats 59% of comparable models) and weakest on EER2 (39%).
  • Generallux
  • Middle half of its models
  • Other ranked manufacturers
Generall…

Source: AHRI Directory, NEEP · as of

Average peer percentile of Generallux’s models
RatingBeats comparable modelsRankRaw median
Efficiency index20 models scored47%Not ranked—
COP at 5°F20 models scored39%Not ranked1.90
Capacity retention at 5°F20 models scored41%Not ranked72%
HSPF220 models scored58%Not ranked10.0
SEER220 models scored59%Not ranked22.5
EER220 models scored39%Not ranked11.2
Heating capacity at 5°F20 models scored51%Not ranked13,600 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Generallux’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • Generallux (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons250%37%52%79%
Ducted, 2 tons156%51%85%76%
Non-ducted, up to 1.5 tons1049%36%57%55%
Non-ducted, 2 tons342%24%65%48%
Non-ducted, 2.5–3 tons346%63%54%57%
Non-ducted, 3.5–4.5 tons142%37%40%73%

Every Generallux model in the market

Generallux’s 20 models with a known size and duct type, over the shape of the whole catalog.
Generallux models by size and ratingColoured: Generallux · grey shapes: all 14,508 models · lines: catalog medians by size
  • Generallux models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 20 generallux models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top Generallux models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 Generallux cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1TFM2G18CHAIR454BGenerallux1.5 tons18,000 Btu/h · Non-ducted80%2.0010.516,00024.0CEE 25CEE 26Xcel1216765715Non-ducted, up to 1.5 tons68.6
2THH12E2S25NAR454OGeneralluxwith ductless indoor unit THH12E2S25NAR454I1 ton12,000 Btu/h · Non-ducted100%1.8010.512,00025.0CEE 25CEE 26Xcel1216765712Non-ducted, up to 1.5 tons62.1
3TSHG24E2S20NAR45OGenerallux2 tons22,000 Btu/h · Ducted74%2.0010.018,50019.0CEE 25CEE 26Xcel3216765727Ducted, 2 tons60.1
4TSHG12E2M23NAR45OGeneralluxwith ductless indoor unit TSHG12E2M23NAR45I1 ton12,000 Btu/h · Non-ducted72%2.1010.09,10024.0CEE 25CEE 26Xcel3216765709Non-ducted, up to 1.5 tons59.5
5TSHG12E1O22NAR45OGeneralluxwith ductless indoor unit TSHG12E1O22NAR45I1 ton12,000 Btu/h · Non-ducted72%2.1010.08,90023.0CEE 25CEE 26Xcel1216765708Non-ducted, up to 1.5 tons58.9

All-around best

Top 5 Generallux models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1THH12E2S25NAR454OGeneralluxwith ductless indoor unit THH12E2S25NAR454I1 ton12,000 Btu/h · Non-ducted100%1.8010.525.014.0CEE 25CEE 26Xcel1216765712Non-ducted, up to 1.5 tons74.462.186.762.1
2TFM2G18CHAIR454BGenerallux1.5 tons18,000 Btu/h · Non-ducted80%2.0010.524.013.0CEE 25CEE 26Xcel1216765715Non-ducted, up to 1.5 tons72.268.675.868.6
3TSHG12E2M23NAR45OGeneralluxwith ductless indoor unit TSHG12E2M23NAR45I1 ton12,000 Btu/h · Non-ducted72%2.1010.024.013.0CEE 25CEE 26Xcel3216765709Non-ducted, up to 1.5 tons67.759.575.859.5
4TFM3G27CHAIR454BGenerallux2.5 tons27,000 Btu/h · Non-ducted71%2.0010.524.012.0CEE 25CEE 26Xcel1216765716Non-ducted, 2.5–3 tons65.157.572.657.5
5TSHG12E1O22NAR45OGeneralluxwith ductless indoor unit TSHG12E1O22NAR45I1 ton12,000 Btu/h · Non-ducted72%2.1010.023.013.0CEE 25CEE 26Xcel1216765708Non-ducted, up to 1.5 tons65.058.971.158.9

Best model on each rating

Generallux’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FTSHG36E2S19NAR45O2.03Non-ducted, 2.5–3 tons81%216765707
Capacity retention at 5°FTHH12E2S25NAR454O100%Non-ducted, up to 1.5 tons87%216765712
HSPF2TSHG24E2S20NAR45O10.4Non-ducted, 2 tons81%216765724
SEER2TFM3G27CHAIR454B24.0Non-ducted, 2.5–3 tons91%216765716
EER2THH12E2S25NAR454O14.0Non-ducted, up to 1.5 tons83%216765712
Heating capacity at 5°FTHH18E2S24NAR454O17,800 Btu/hNon-ducted, up to 1.5 tons90%216765713

All 17 Generallux models in Explore

Generallux size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Generallux: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons54.1(50 is the typical model of its size class)TSHG18E2S22NAR45O2 of 2 models qualify · AHRI 21676572657.0(50 is the typical model of its size class)TSHG18E2S22NAR45O2 of 2 models have all five ratings · AHRI 216765726
Ducted, 2 tons60.1(50 is the typical model of its size class)TSHG24E2S20NAR45O1 of 1 models qualify · AHRI 21676572755.8(50 is the typical model of its size class)TSHG24E2S20NAR45O1 of 1 models have all five ratings · AHRI 216765727
Non-ducted, up to 1.5 tons68.6(50 is the typical model of its size class)TFM2G18CHAIR454B7 of 10 models qualify · AHRI 21676571574.4(50 is the typical model of its size class)THH12E2S25NAR454Owith ductless indoor unit THH12E2S25NAR454I10 of 10 models have all five ratings · AHRI 216765712
Non-ducted, 2 tons58.8(50 is the typical model of its size class)TSHG24E2S20NAR45Owith ductless indoor unit TSCAS24CD2VIR45I2 of 3 models qualify · AHRI 21676572456.5(50 is the typical model of its size class)TSHG24E2S20NAR45Owith ductless indoor unit TSCAS24CD2VIR45I3 of 3 models have all five ratings · AHRI 216765724
Non-ducted, 2.5–3 tons57.5(50 is the typical model of its size class)TFM3G27CHAIR454B2 of 3 models qualify · AHRI 21676571665.1(50 is the typical model of its size class)TFM3G27CHAIR454B3 of 3 models have all five ratings · AHRI 216765716
Non-ducted, 3.5–4.5 tons31.2(50 is the typical model of its size class)TFM5G42CHAIR454B1 of 1 models qualify · AHRI 21676571842.4(50 is the typical model of its size class)TFM5G42CHAIR454B1 of 1 models have all five ratings · AHRI 216765718

All-around board, every manufacturer

Newest Generallux certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified Generallux outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
TSHG24E2S20NAR45OGenerallux2 tons22,000 Btu/h · Ducted and non-ducted2.0074%10.019.0CEE 25CEE 26Xcel3216765727
TSHG18E2S22NAR45OGenerallux1.5 tons17,000 Btu/h · Ducted and non-ducted1.8073%10.020.3CEE 25CEE 26Xcel3216765726
TSHG12E2M23NAR45OGenerallux1 ton11,000 Btu/h · Ducted and non-ducted1.8073%8.419.0CEE 25CEE 26Xcel3216765725
TAC24CHSAG2R32O18Generalluxwith ductless indoor unit TAC24CHSAG2R32I182 tons23,000 Btu/h · Non-ducted1.8054%9.517.0None1216765721
TAC18CHSAG2R32O18Generalluxwith ductless indoor unit TAC18CHSAG2R32I181.5 tons17,000 Btu/h · Non-ducted1.8058%8.517.0None1216765720

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare Generallux

Manufacturers of a similar size, side by side.

Generallux includes these brand names as listed in AHRI: Generallux. Standards are checked against published thresholds; program rules beyond ratings are not checked.