- Insights
- Manufacturers
- DAIZUKI
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
DAIZUKI heat pump efficiency: 12 outdoor models compared
DAIZUKI has 12 heat pump outdoor models certified with this refrigerant group, in 12 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes DAIZUKI makes. DAIZUKI has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 12
- AHRI certifications
- 12
- Efficiency index
- 47%
- Typical model vs same-size, same-type peers (12 models)
- Meet CEE 2025
- 91.7%
- 11 models
How DAIZUKI compares with comparable models
- DAIZUKI
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index12 models scored | 47% | Not ranked | — |
| COP at 5°F12 models scored | 39% | Not ranked | 1.93 |
| Capacity retention at 5°F12 models scored | 41% | Not ranked | 71% |
| HSPF212 models scored | 47% | Not ranked | 10.0 |
| SEER212 models scored | 61% | Not ranked | 22.3 |
| EER212 models scored | 44% | Not ranked | 11.7 |
| Heating capacity at 5°F12 models scored | 45% | Not ranked | 16,900 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 91.7% | 11 |
| CEE 2026 Tier 1 (Split ASHP) | 91.7% | 11 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 75% | 9 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- DAIZUKI (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 6 | 50% | 35% | 46% | 62% |
| Non-ducted, 2 tons | 2 | 49% | 52% | 47% | 60% |
| Non-ducted, 2.5–3 tons | 3 | 41% | 38% | 50% | 54% |
| Non-ducted, 3.5–4.5 tons | 1 | 43% | 37% | 40% | 73% |
Every DAIZUKI model in the market
- DAIZUKI models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 865 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 726 | 1.80 | 1.86 | 2.00 | 2.12 | 2.41 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top DAIZUKI models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1DXFMT-1824-2ZDAIZUKI | 1.5 tons18,000 Btu/h · Non-ducted | 80% | 2.00 | 10.5 | 16,000 | 24.0 | CEE 25CEE 26Xcel | 1 | 217500268 | Non-ducted, up to 1.5 tons | 68.6 |
| 2DXTH12C526A-25DAIZUKIwith ductless indoor unit DXTH12E526A-25 | 1 ton12,000 Btu/h · Non-ducted | 100% | 1.80 | 10.5 | 12,000 | 25.0 | CEE 25CEE 26Xcel | 1 | 217996672 | Non-ducted, up to 1.5 tons | 62.1 |
| 3DXTH24C526A-25DAIZUKIwith ductless indoor unit DXTH24E526A-25 | 2 tons24,000 Btu/h · Non-ducted | 93% | 1.80 | 10.0 | 22,400 | 22.5 | CEE 25CEE 26Xcel | 1 | 217996674 | Non-ducted, 2 tons | 58.0 |
| 4DXFMT-2724-3ZDAIZUKI | 2.5 tons27,000 Btu/h · Non-ducted | 71% | 2.00 | 10.5 | 19,800 | 24.0 | CEE 25CEE 26Xcel | 1 | 217500269 | Non-ducted, 2.5–3 tons | 57.5 |
| 5DXTH18C526A-25DAIZUKIwith ductless indoor unit DXTH18E526A-25 | 1.5 tons18,000 Btu/h · Non-ducted | 99% | 1.80 | 10.0 | 17,800 | 23.5 | CEE 25CEE 26Xcel | 1 | 217996673 | Non-ducted, up to 1.5 tons | 55.9 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1DXTH12C526A-25DAIZUKIwith ductless indoor unit DXTH12E526A-25 | 1 ton12,000 Btu/h · Non-ducted | 100% | 1.80 | 10.5 | 25.0 | 14.0 | CEE 25CEE 26Xcel | 1 | 217996672 | Non-ducted, up to 1.5 tons | 74.4 | 62.1 | 86.7 | 62.1 |
| 2DXFMT-1824-2ZDAIZUKI | 1.5 tons18,000 Btu/h · Non-ducted | 80% | 2.00 | 10.5 | 24.0 | 13.0 | CEE 25CEE 26Xcel | 1 | 217500268 | Non-ducted, up to 1.5 tons | 72.2 | 68.6 | 75.8 | 68.6 |
| 3DXFMT-2724-3ZDAIZUKI | 2.5 tons27,000 Btu/h · Non-ducted | 71% | 2.00 | 10.5 | 24.0 | 12.0 | CEE 25CEE 26Xcel | 1 | 217500269 | Non-ducted, 2.5–3 tons | 65.1 | 57.5 | 72.6 | 57.5 |
| 4DXTH18C526A-25DAIZUKIwith ductless indoor unit DXTH18E526A-25 | 1.5 tons18,000 Btu/h · Non-ducted | 99% | 1.80 | 10.0 | 23.5 | 12.5 | CEE 25CEE 26Xcel | 1 | 217996673 | Non-ducted, up to 1.5 tons | 61.2 | 55.9 | 66.5 | 55.9 |
| 5DXTH24C526A-25DAIZUKIwith ductless indoor unit DXTH24E526A-25 | 2 tons24,000 Btu/h · Non-ducted | 93% | 1.80 | 10.0 | 22.5 | 11.7 | CEE 25CEE 26Xcel | 1 | 217996674 | Non-ducted, 2 tons | 56.1 | 58.0 | 54.2 | 58.0 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | DXTH24C626A-21 | 2.25 | Non-ducted, 2 tons | 88% | 217604098 |
| Capacity retention at 5°F | DXTH12C526A-25 | 100% | Non-ducted, up to 1.5 tons | 87% | 217996672 |
| HSPF2 | DXFMT-2724-3Z | 10.5 | Non-ducted, 2.5–3 tons | 80% | 217500269 |
| SEER2 | DXFMT-2724-3Z | 24.0 | Non-ducted, 2.5–3 tons | 91% | 217500269 |
| EER2 | DXTH12C526A-25 | 14.0 | Non-ducted, up to 1.5 tons | 83% | 217996672 |
| Heating capacity at 5°F | DXTH18C526A-25 | 17,800 Btu/h | Non-ducted, up to 1.5 tons | 90% | 217996673 |
DAIZUKI size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 68.6(50 is the typical model of its size class)DXFMT-1824-2Z5 of 6 models qualify · AHRI 217500268 | 74.4(50 is the typical model of its size class)DXTH12C526A-25with ductless indoor unit DXTH12E526A-256 of 6 models have all five ratings · AHRI 217996672 |
| Non-ducted, 2 tons | 58.0(50 is the typical model of its size class)DXTH24C526A-25with ductless indoor unit DXTH24E526A-251 of 2 models qualify · AHRI 217996674 | 56.1(50 is the typical model of its size class)DXTH24C526A-25with ductless indoor unit DXTH24E526A-252 of 2 models have all five ratings · AHRI 217996674 |
| Non-ducted, 2.5–3 tons | 57.5(50 is the typical model of its size class)DXFMT-2724-3Z2 of 3 models qualify · AHRI 217500269 | 65.1(50 is the typical model of its size class)DXFMT-2724-3Z3 of 3 models have all five ratings · AHRI 217500269 |
| Non-ducted, 3.5–4.5 tons | 32.0(50 is the typical model of its size class)DXFMT-4224-5Z1 of 1 models qualify · AHRI 217500271 | 42.9(50 is the typical model of its size class)DXFMT-4224-5Z1 of 1 models have all five ratings · AHRI 217500271 |
Newest DAIZUKI certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| DXTH36C626A-17DAIZUKIwith ductless indoor unit DXTH36E626A-17 | 3 tons35,000 Btu/h · Non-ducted | 1.80 | 51% | 8.5 | 17.0 | None | 1 | 218467217 |
| DXTH24C526A-25DAIZUKIwith ductless indoor unit DXTH24E526A-25 | 2 tons24,000 Btu/h · Non-ducted | 1.80 | 93% | 10.0 | 22.5 | CEE 25CEE 26Xcel | 1 | 217996674 |
| DXTH18C526A-25DAIZUKIwith ductless indoor unit DXTH18E526A-25 | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 99% | 10.0 | 23.5 | CEE 25CEE 26Xcel | 1 | 217996673 |
| DXTH12C526A-25DAIZUKIwith ductless indoor unit DXTH12E526A-25 | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 100% | 10.5 | 25.0 | CEE 25CEE 26Xcel | 1 | 217996672 |
| DXTH24C626A-21DAIZUKIwith ductless indoor unit DXTH24E626A-21 | 2 tons23,000 Btu/h · Non-ducted | 2.25 | 55% | 9.0 | 21.0 | CEE 25CEE 26 | 1 | 217604098 |
Compare DAIZUKI
DAIZUKI includes these brand names as listed in AHRI: DAIZUKI. Standards are checked against published thresholds; program rules beyond ratings are not checked.