Skip to content

LUORISE heat pump efficiency: 27 outdoor models compared

LUORISE has 27 heat pump outdoor models certified with this refrigerant group, in 27 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes LUORISE makes. LUORISE has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
27
AHRI certifications
27
Efficiency index
30%
Typical model vs same-size, same-type peers (27 models)
Meet CEE 2025
48.1%
13 models

How LUORISE compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
LUORISE against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of LUORISE’s own modelsLUORISE is strongest on HSPF2 (its typical model beats 42% of comparable models) and weakest on EER2 (21%).
  • LUORISE
  • Middle half of its models
  • Other ranked manufacturers
LUORISE

Source: AHRI Directory, NEEP · as of

Average peer percentile of LUORISE’s models
RatingBeats comparable modelsRankRaw median
Efficiency index27 models scored30%Not ranked—
COP at 5°F27 models scored31%Not ranked1.90
Capacity retention at 5°F27 models scored30%Not ranked71%
HSPF227 models scored42%Not ranked9.5
SEER227 models scored28%Not ranked20.0
EER227 models scored21%Not ranked9.5
Heating capacity at 5°F27 models scored36%Not ranked12,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
LUORISE’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • LUORISE (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons1633%32%47%33%
Non-ducted, 2 tons624%25%44%17%
Non-ducted, 2.5–3 tons426%30%30%24%
Non-ducted, 3.5–4.5 tons127%37%14%30%

Every LUORISE model in the market

LUORISE’s 27 models with a known size and duct type, over the shape of the whole catalog.
LUORISE models by size and ratingColoured: LUORISE · grey shapes: all 14,508 models · lines: catalog medians by size
  • LUORISE models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 27 luorise models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top LUORISE models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 LUORISE cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1L01-2Z-18K2V-20S-OLUORISE1.5 tons18,000 Btu/h · Non-ducted78%2.0010.014,00025.0CEE 25CEE 26Xcel1218046436Non-ducted, up to 1.5 tons62.1
2L01-CS-09K2V-20S-OLUORISEwith ductless indoor unit L01-CS-09K2V-20S-WC-I1 ton9,000 Btu/h · Non-ducted83%1.9010.07,50023.0CEE 25CEE 26Xcel1218468364Non-ducted, up to 1.5 tons58.9
3L01-DU-09K2V-20S-OLUORISEwith ductless indoor unit L01-DU-09K2V-20S-WC-I1 ton9,000 Btu/h · Non-ducted86%1.909.57,70020.0CEE 25CEE 26Xcel1218468368Non-ducted, up to 1.5 tons52.9
4L01-3Z-27K2V-20S-OLUORISE2.5 tons28,000 Btu/h · Non-ducted75%2.009.521,00020.0CEE 25CEE 26Xcel1218046437Non-ducted, 2.5–3 tons47.6
5L01-4Z-36K2V-20S-OLUORISE3 tons38,000 Btu/h · Non-ducted74%2.009.531,00020.0CEE 25CEE 26Xcel1218046438Non-ducted, 2.5–3 tons46.9

All-around best

Top 5 LUORISE models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1L01-2Z-18K2V-20S-OLUORISE1.5 tons18,000 Btu/h · Non-ducted78%2.0010.025.011.7CEE 25CEE 26Xcel1218046436Non-ducted, up to 1.5 tons62.262.162.462.1
2L01-CS-09K2V-20S-OLUORISEwith ductless indoor unit L01-CS-09K2V-20S-WC-I1 ton9,000 Btu/h · Non-ducted83%1.9010.023.012.5CEE 25CEE 26Xcel1218468364Non-ducted, up to 1.5 tons61.458.963.858.9
3L01-09K2V-20S-P-OLUORISEwith ductless indoor unit L01-09K2V-20S-WC-I1 ton9,000 Btu/h · Non-ducted80%1.809.521.012.5CEE 25CEE 26Xcel1218046434Non-ducted, up to 1.5 tons46.642.251.042.2
4L01-DU-09K2V-20S-OLUORISEwith ductless indoor unit L01-DU-09K2V-20S-WC-I1 ton9,000 Btu/h · Non-ducted86%1.909.520.012.0CEE 25CEE 26Xcel1218468368Non-ducted, up to 1.5 tons45.152.937.352.9
5L01-09K1V-20S-P-OLUORISEwith ductless indoor unit L01-09K1V-20S-WC-I1 ton9,000 Btu/h · Non-ducted80%1.809.520.012.0CEE 25CEE 26Xcel1218046432Non-ducted, up to 1.5 tons39.742.237.342.2

Best model on each rating

LUORISE’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FL01-2Z-18K2V-20S-O2.00Non-ducted, up to 1.5 tons63%218046436
Capacity retention at 5°FL01-DU-09K2V-20S-O86%Non-ducted, up to 1.5 tons69%218468368
HSPF2L01-18K2V-20S-P-O10.0Non-ducted, up to 1.5 tons64%218046429
SEER2L01-2Z-18K2V-20S-O25.0Non-ducted, up to 1.5 tons84%218046436
EER2L01-09K2V-20S-P-O12.5Non-ducted, up to 1.5 tons56%218046434
Heating capacity at 5°FL01-2Z-18K2V-20S-O14,000 Btu/hNon-ducted, up to 1.5 tons83%218046436

All 27 LUORISE models in Explore

LUORISE size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
LUORISE: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tons62.1(50 is the typical model of its size class)L01-2Z-18K2V-20S-O8 of 16 models qualify · AHRI 21804643662.2(50 is the typical model of its size class)L01-2Z-18K2V-20S-O16 of 16 models have all five ratings · AHRI 218046436
Non-ducted, 2 tons37.4(50 is the typical model of its size class)L01-CS-24K2V-20S-Owith ductless indoor unit L01-CS-24K2V-20S-WC-I3 of 6 models qualify · AHRI 21846836735.1(50 is the typical model of its size class)L01-FC-24K2V-20S-Owith ductless indoor unit L01-FC-24K2V-20S-WC-I6 of 6 models have all five ratings · AHRI 218468373
Non-ducted, 2.5–3 tons47.6(50 is the typical model of its size class)L01-3Z-27K2V-20S-O2 of 4 models qualify · AHRI 21804643738.7(50 is the typical model of its size class)L01-3Z-27K2V-20S-O4 of 4 models have all five ratings · AHRI 218046437
Non-ducted, 3.5–4.5 tons24.7(50 is the typical model of its size class)L01-5Z-42K2V-20S-O1 of 1 models qualify · AHRI 21804643927.2(50 is the typical model of its size class)L01-5Z-42K2V-20S-O1 of 1 models have all five ratings · AHRI 218046439

All-around board, every manufacturer

Newest LUORISE certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified LUORISE outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
L02-36K2V-17S-P-OLUORISEwith ductless indoor unit L02-36K2V-17S-WC-I3 tons35,000 Btu/h · Non-ducted1.8051%8.517.0None1218736941
L02-24K2V-17S-P-OLUORISEwith ductless indoor unit L02-24K2V-17S-WC-I2 tons23,000 Btu/h · Non-ducted1.8054%9.517.0None1218736940
L02-18K2V-17S-P-OLUORISEwith ductless indoor unit L02-18K2V-17S-WC-I1.5 tons17,000 Btu/h · Non-ducted1.8058%8.517.0None1218736939
L02-12K2V-17S-P-OLUORISEwith ductless indoor unit L02-12K2V-17S-WC-I1 ton11,500 Btu/h · Non-ducted1.7561%8.517.0None1218736938
L01-FC-24K2V-20S-OLUORISEwith ductless indoor unit L01-FC-24K2V-20S-WC-I2 tons24,000 Btu/h · Non-ducted1.9071%9.520.0CEE 25CEE 26Xcel1218468373

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare LUORISE

Manufacturers of a similar size, side by side.

LUORISE includes these brand names as listed in AHRI: LUORISE. Standards are checked against published thresholds; program rules beyond ratings are not checked.