Skip to content

Gree vs Midea heat pumps

Measured against models of the same size and duct type, Midea scores higher on 4 of the 6 ratings. Gree has 717 outdoor models, Midea has 546 outdoor models. They share hardware: 83 equipment families appear under both names.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Gree and Midea on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Midea scores higher on 4 of the 6 ratings.
  • Gree
  • Midea
  • Other ranked manufacturers
GreeMidea

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingGreeMidea
Efficiency index54%median — · 12th ranked59%median — · 7th ranked
COP at 5°F43%median 1.94 · 25th ranked59%median 2.00 · 9th ranked
Capacity retention at 5°F57% (higher)median 77% · 10th ranked56% (higher)median 74% · 11th ranked
HSPF242%median 9.0 · 24th ranked66%median 9.5 · 7th ranked
SEER260%median 20.5 · 7th ranked61%median 19.5 · 6th ranked
EER260% (higher)median 12.0 · 6th ranked54% (higher)median 11.7 · 15th ranked
Heating capacity at 5°F55%median 16,950 Btu/h · 13th ranked59%median 20,400 Btu/h · 10th ranked
Outdoor models717546
AHRI certifications5,1735,356

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardGreeMidea
CEE 2025 Tier 1 (Split ASHP)80.9%580 models75.5%412 models
CEE 2026 Tier 1 (Split ASHP)79.8%572 models73.8%403 models
CEE Advanced Tier (Split ASHP)5.6%40 models3.1%17 models
Xcel Energy Colorado cold-climate ASHP (2025)80.1%574 models69.8%381 models
DOE Cold Climate Heat Pump Challenge5.6%40 models3.1%17 models
ENERGY STAR Cold Climate66.1%474 models63.9%349 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 10 groups where both have models
  • Gree
  • Midea
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeGreeMidea
Ducted, up to 1.5 tons96 · index 66%79 · index 73%
Ducted, 2 tons68 · index 57%57 · index 62%
Ducted, 2.5–3 tons120 · index 54%121 · index 61%
Ducted, 3.5–4.5 tons120 · index 58%109 · index 63%
Ducted, 5 tons and up4 · index 60%22 · index 63%
Non-ducted, up to 1.5 tons314 · index 51%179 · index 55%
Non-ducted, 2 tons82 · index 55%50 · index 51%
Non-ducted, 2.5–3 tons81 · index 47%92 · index 55%
Non-ducted, 3.5–4.5 tons47 · index 47%64 · index 50%
Non-ducted, 5 tons and up3 · index 65%15 · index 44%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeGreeCold-climate score, best modelMideaCold-climate score, best model
Ducted, up to 1.5 tons85.5(50 is the typical model of its size class)SPHP-Z-V018BBwith ducted air handler AIRH-Z-V018V06C88 of 95 models qualify · AHRI 21649796293.5(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK70 of 80 models qualify · AHRI 215324042
Ducted, 2 tons77.1(50 is the typical model of its size class)MHPC-H-024BSBwith ducted air handler MDUC-H-024BBB73 of 84 models qualify · AHRI 21649793486.4(50 is the typical model of its size class) (higher)MOU-B24H-2with ducted air handler MIU-B24D-249 of 54 models qualify · AHRI 217022110
Ducted, 2.5–3 tons77.4(50 is the typical model of its size class)SPHP-Z-V036BBwith ducted air handler AIRH-Z-V036V12C62 of 105 models qualify · AHRI 21649796588.8(50 is the typical model of its size class) (higher)MOE30-36HFN10-M3Xwith ducted air handler MVBDM-36HWFN10-WC391 of 125 models qualify · AHRI 216967947
Ducted, 3.5–4.5 tons88.7(50 is the typical model of its size class) (higher)GUD60W2/NHE-D(U)with ducted air handler HND60A/NHA-O79 of 120 models qualify · AHRI 21804337183.9(50 is the typical model of its size class)MOVA-60HDN10-M20Gwith ducted air handler MVME60C2MN10TAAlso listed as MOVC-60HDN10-M20G91 of 106 models qualify · AHRI 214814477
Ducted, 5 tons and up69.3(50 is the typical model of its size class) (higher)TMV-V60WL/NHC-T(U)2 of 4 models qualify · AHRI 21677230665.9(50 is the typical model of its size class)MDV-V60WMN10T5 of 23 models qualify · AHRI 216021062
Non-ducted, up to 1.5 tons89.5(50 is the typical model of its size class)MHPC-H-009BSBwith ductless indoor unit MCON-H-009BBB296 of 314 models qualify · AHRI 21649793897.5(50 is the typical model of its size class) (higher)MOX230-06HFN10-M1with ductless indoor unit MSEPB-06HRFN10-M1121 of 179 models qualify · AHRI 215865890
Non-ducted, 2 tons84.5(50 is the typical model of its size class)MHPC-H-024BSBwith ductless indoor unit MWAL-H-024BBB68 of 82 models qualify · AHRI 21649791989.4(50 is the typical model of its size class) (higher)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as MDV MOD30-24HFN10-M1X; also listed as D5CSHAH24AAK44 of 50 models qualify · AHRI 215324059
Non-ducted, 2.5–3 tons77.2(50 is the typical model of its size class)GWHD(36)ND6MOAlso sold as Tosot TM36H32MO, Kinghome KM36X6O, Tosot MZ-COSMO36/O, Tosot TM36D6MO and 6 more; also listed as MUL36HP230V1R32AO, GS4M36HP230V1MO, GWHD(36)ND6CO74 of 81 models qualify · AHRI 21493158989.8(50 is the typical model of its size class) (higher)MOU-B36LH-2with ductless indoor unit MIU-B36LF-276 of 92 models qualify · AHRI 217022114
Non-ducted, 3.5–4.5 tons66.5(50 is the typical model of its size class)GWHD(42)ND6MOAlso sold as Tosot TM42H32MO, Kinghome KM42X6O, Tosot TM42D6MO, Tosot TMSCI7H4R42 and 5 more; also listed as MUL42HP230V1R32AO, GS5M42HP230V1MO31 of 47 models qualify · AHRI 21493159075.5(50 is the typical model of its size class) (higher)D5CMHAH48FAKAlso sold as MDV M6OE31-48HFN10-M1XD, MDV M6OE31-48HFN10-M1X; also listed as 37MGHAQ48FA357 of 64 models qualify · AHRI 215357417
Non-ducted, 5 tons and up53.2(50 is the typical model of its size class) (higher)GMV-V60WL/NHC-T(U)Also sold as Tosot TMV-V60WL/NHC-T(U)2 of 3 models qualify · AHRI 21677224950.6(50 is the typical model of its size class)MDV-V60WMN10TAlso listed as MDV-V60WMN10T(B)3 of 15 models qualify · AHRI 216021081

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeGreeAll-around score, best modelMideaAll-around score, best model
Ducted, up to 1.5 tons83.7(50 is the typical model of its size class)GS09HP230V1PUOwith ducted air handler GS09HP230V1DAI95 of 95 models have all five ratings · AHRI 21863637795.6(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK80 of 80 models have all five ratings · AHRI 215324042
Ducted, 2 tons82.9(50 is the typical model of its size class)A7CP21V24P-**Awith ducted air handler 7AH2AE24PX-75 of 75 models have all five ratings · AHRI 21746595389.9(50 is the typical model of its size class) (higher)MOD30-24HFN10-M1Hwith ducted air handler MSEPD-24HRFN10-M1H57 of 57 models have all five ratings · AHRI 217998293
Ducted, 2.5–3 tons79.8(50 is the typical model of its size class)A7CP21V36P-**Awith ducted air handler 7AH1AV42PX-113 of 113 models have all five ratings · AHRI 21746590685.5(50 is the typical model of its size class) (higher)D5CMHAH30EAKAlso sold as MDV M5OX631-30HFN10-M1XD; also listed as 37MGHAQ30EA3120 of 120 models have all five ratings · AHRI 215357410
Ducted, 3.5–4.5 tons85.1(50 is the typical model of its size class)MHPC-H-048BMB120 of 120 models have all five ratings · AHRI 21649795185.7(50 is the typical model of its size class) (higher)D5CMRAH48FAKAlso sold as MDV M6OE30-48HFN10-M1D, MDV M6OE30-48HFN10-M1; also listed as 37MGRAQ48FA3109 of 109 models have all five ratings · AHRI 215357445
Ducted, 5 tons and up66.7(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-5 of 5 models have all five ratings · AHRI 21637130370.1(50 is the typical model of its size class) (higher)MRD-60HWD1N10-M18GAlso listed as MRD-60HWD1N10-M18GB22 of 22 models have all five ratings · AHRI 215894250
Non-ducted, up to 1.5 tons92.6(50 is the typical model of its size class)MHPC-H-009BSBwith ductless indoor unit MCON-H-009BBB310 of 314 models have all five ratings · AHRI 21649793896.5(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ductless indoor unit D5MAHAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK170 of 179 models have all five ratings · AHRI 215323786
Non-ducted, 2 tons86.8(50 is the typical model of its size class)MHPC-H-024BSBwith ductless indoor unit MWAL-H-024BBB78 of 82 models have all five ratings · AHRI 21649791988.5(50 is the typical model of its size class) (higher)37MARAQ24AA3with ductless indoor unit D5MAHAQ24XA3Also sold as MDV MOD30-24HFN10-M1; also listed as D5CSRAH24AAK46 of 50 models have all five ratings · AHRI 215323796
Non-ducted, 2.5–3 tons75.1(50 is the typical model of its size class)GMV-V36WL/NHC-T(U)Also sold as Tosot TMV-V36WL/NHC-T(U)81 of 81 models have all five ratings · AHRI 21712344385.8(50 is the typical model of its size class) (higher)D5CMHAH30EAKAlso sold as MDV M5OX631-30HFN10-M1XD; also listed as 37MGHAQ30EA391 of 92 models have all five ratings · AHRI 215357409
Non-ducted, 3.5–4.5 tons68.6(50 is the typical model of its size class)MHPC-H-048BMB45 of 47 models have all five ratings · AHRI 21649795276.7(50 is the typical model of its size class) (higher)D5CMHAH48FAKAlso sold as MDV M6OE31-48HFN10-M1XD, MDV M6OE31-48HFN10-M1X; also listed as 37MGHAQ48FA363 of 64 models have all five ratings · AHRI 215357415
Non-ducted, 5 tons and up68.8(50 is the typical model of its size class) (higher)GMV-V60WL/NHC-T(U)Also sold as Tosot TMV-V60WL/NHC-T(U)3 of 3 models have all five ratings · AHRI 21677224961.3(50 is the typical model of its size class)D5CMRAH55FAKAlso sold as MDV M6OE30-60HFN10-M1D, MDV M6OE30-60HFN10-M1; also listed as 37MGRAQ55FA315 of 15 models have all five ratings · AHRI 215357450

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingGreeMidea
COP at 5°Fbeats 99% · 2.40GMV-V36WL/NHC-T(U)Also sold as Tosot TMV-V36WL/NHC-T(U)Non-ducted, 2.5–3 tonsbeats 99% · 2.5137MARAQ12AA3Also sold as MDV MOX230-12HFN10-M1; also listed as D5CSRAH12AAKNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 99% · 126%GK-H02TC/NHA-D(U)Also sold as Ac Pro PKHP-X-024VBC, Tosot TK-H02TC/NHA-D(U)Ducted, 2 tonsbeats 100% · 150%37MPRAQ06AA3Also sold as MDV MOX430-06HFN10-M1HNon-ducted, up to 1.5 tons
HSPF2beats 98% · 10.8SPHP-Z-V030BBDucted, 2.5–3 tonsbeats 100% · 15.637MPRAQ06AA3Also sold as MDV MOX430-06HFN10-M1HNon-ducted, up to 1.5 tons
SEER2beats 100% · 24.5GWH18AVEXF-D6DNA1A/OAlso sold as Kinghome KW18XQ29SDO, Tosot TW18HAY32A1DO, Tosot TW18HAY32A1DOC, Tosot TWH18AD32AO and 1 more; also listed as GWH18AVEXF-D6DNA1B/ODucted, up to 1.5 tonsbeats 100% · 27.0MOX430-15HFN10-M1HDucted, up to 1.5 tons
EER2beats 100% · 14.5BH714S18P-**ADucted, up to 1.5 tonsbeats 100% · 18.1MOX230-06HFN10-M1Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 30,300 Btu/hGK-H02TC/NHA-D(U)Also sold as Ac Pro PKHP-X-024VBC, Tosot TK-H02TC/NHA-D(U)Ducted, 2 tonsbeats 100% · 55,000 Btu/hMOVA-60HDN10-M20GAlso listed as MOVC-60HDN10-M20GDucted, 3.5–4.5 tons

More comparisons