Skip to content

Carrier vs Gree heat pumps

Measured against models of the same size and duct type, Gree scores higher on 5 of the 6 ratings. Carrier has 816 outdoor models, Gree has 717 outdoor models.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Carrier and Gree on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Gree scores higher on 5 of the 6 ratings.
  • Carrier
  • Gree
  • Other ranked manufacturers
CarrierGree

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCarrierGree
Efficiency index48%median — · 23rd ranked54%median — · 12th ranked
COP at 5°F56% (higher)median 2.04 · 16th ranked43% (higher)median 1.94 · 25th ranked
Capacity retention at 5°F34%median 53% · 28th ranked57%median 77% · 10th ranked
HSPF240%median 7.8 · 25th ranked42%median 9.0 · 24th ranked
SEER242%median 15.2 · 23rd ranked60%median 20.5 · 7th ranked
EER259%median 11.5 · 8th ranked60%median 12.0 · 6th ranked
Heating capacity at 5°F37%median 18,600 Btu/h · 27th ranked55%median 16,950 Btu/h · 13th ranked
Outdoor models816717
AHRI certifications521,4035,173

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCarrierGree
CEE 2025 Tier 1 (Split ASHP)40.2%328 models80.9%580 models
CEE 2026 Tier 1 (Split ASHP)35.3%288 models79.8%572 models
CEE Advanced Tier (Split ASHP)1%8 models5.6%40 models
Xcel Energy Colorado cold-climate ASHP (2025)27.2%222 models80.1%574 models
DOE Cold Climate Heat Pump Challenge1%8 models5.6%40 models
ENERGY STAR Cold Climate26.7%218 models66.1%474 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 10 groups where both have models
  • Carrier
  • Gree
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCarrierGree
Ducted, up to 1.5 tons69 · index 56%96 · index 66%
Ducted, 2 tons93 · index 47%68 · index 57%
Ducted, 2.5–3 tons228 · index 45%120 · index 54%
Ducted, 3.5–4.5 tons306 · index 44%120 · index 58%
Ducted, 5 tons and up68 · index 50%4 · index 60%
Non-ducted, up to 1.5 tons54 · index 59%314 · index 51%
Non-ducted, 2 tons16 · index 57%82 · index 55%
Non-ducted, 2.5–3 tons30 · index 55%81 · index 47%
Non-ducted, 3.5–4.5 tons22 · index 47%47 · index 47%
Non-ducted, 5 tons and up4 · index 57%3 · index 65%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCarrierCold-climate score, best modelGreeCold-climate score, best model
Ducted, up to 1.5 tons93.5(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK30 of 68 models qualify · AHRI 21532379885.5(50 is the typical model of its size class)SPHP-Z-V018BBwith ducted air handler AIRH-Z-V018V06C88 of 95 models qualify · AHRI 216497962
Ducted, 2 tons85.7(50 is the typical model of its size class) (higher)37MAHAQ24AA3with ducted air handler 45MBDAQ24XH3Also sold as Arcoaire D5CSHAH24AAK44 of 94 models qualify · AHRI 21532381777.1(50 is the typical model of its size class)MHPC-H-024BSBwith ducted air handler MDUC-H-024BBB73 of 84 models qualify · AHRI 216497934
Ducted, 2.5–3 tons83.2(50 is the typical model of its size class) (higher)37MGHAQ36EA3Also sold as Arcoaire D5CMHAH36EAK59 of 229 models qualify · AHRI 21535711977.4(50 is the typical model of its size class)SPHP-Z-V036BBwith ducted air handler AIRH-Z-V036V12C62 of 105 models qualify · AHRI 216497965
Ducted, 3.5–4.5 tons89.7(50 is the typical model of its size class) (higher)H5H0V48*K*AAA*with indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120A63 of 293 models qualify · AHRI 21837271488.7(50 is the typical model of its size class)GUD60W2/NHE-D(U)with ducted air handler HND60A/NHA-O79 of 120 models qualify · AHRI 218043371
Ducted, 5 tons and up94.7(50 is the typical model of its size class) (higher)MCY-MUB0608HS2P-UL19 of 80 models qualify · AHRI 21676324969.3(50 is the typical model of its size class)TMV-V60WL/NHC-T(U)2 of 4 models qualify · AHRI 216772306
Non-ducted, up to 1.5 tons96.8(50 is the typical model of its size class) (higher)D5CPRAH18AAwith ductless indoor unit D5FPHAH18XAK35 of 54 models qualify · AHRI 21541321489.5(50 is the typical model of its size class)MHPC-H-009BSBwith ductless indoor unit MCON-H-009BBB296 of 314 models qualify · AHRI 216497938
Non-ducted, 2 tons89.4(50 is the typical model of its size class) (higher)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as Arcoaire D5CSHAH24AAK15 of 16 models qualify · AHRI 21532381584.5(50 is the typical model of its size class)MHPC-H-024BSBwith ductless indoor unit MWAL-H-024BBB68 of 82 models qualify · AHRI 216497919
Non-ducted, 2.5–3 tons89.4(50 is the typical model of its size class) (higher)37MBHAQ36AA3with ductless indoor unit 45MCFAQ36XA3Also sold as Arcoaire D5CLHAH36AAK21 of 30 models qualify · AHRI 21532384377.2(50 is the typical model of its size class)GWHD(36)ND6MOAlso sold as Tosot TM36H32MO, Kinghome KM36X6O, Tosot MZ-COSMO36/O, Tosot TM36D6MO and 6 more; also listed as MUL36HP230V1R32AO, GS4M36HP230V1MO, GWHD(36)ND6CO74 of 81 models qualify · AHRI 214931589
Non-ducted, 3.5–4.5 tons79.4(50 is the typical model of its size class) (higher)RAV-BP421AT2P-ULwith ductless indoor unit RAV-HB421CTP-UL18 of 22 models qualify · AHRI 21641547266.5(50 is the typical model of its size class)GWHD(42)ND6MOAlso sold as Tosot TM42H32MO, Kinghome KM42X6O, Tosot TM42D6MO, Tosot TMSCI7H4R42 and 5 more; also listed as MUL42HP230V1R32AO, GS5M42HP230V1MO31 of 47 models qualify · AHRI 214931590
Non-ducted, 5 tons and up50.6(50 is the typical model of its size class)37VMB060HDS3-11 of 4 models qualify · AHRI 21636971453.2(50 is the typical model of its size class) (higher)GMV-V60WL/NHC-T(U)Also sold as Tosot TMV-V60WL/NHC-T(U)2 of 3 models qualify · AHRI 216772249

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCarrierAll-around score, best modelGreeAll-around score, best model
Ducted, up to 1.5 tons95.6(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK64 of 68 models have all five ratings · AHRI 21532379883.7(50 is the typical model of its size class)GS09HP230V1PUOwith ducted air handler GS09HP230V1DAI95 of 95 models have all five ratings · AHRI 218636377
Ducted, 2 tons82.9(50 is the typical model of its size class)27VNA324A*030*with ducted air handler FE5BN(B,X)C36L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN024**AA, HEIL B5H3V24*K*AAA90 of 90 models have all five ratings · AHRI 21762425282.9(50 is the typical model of its size class)A7CP21V24P-**Awith ducted air handler 7AH2AE24PX-75 of 75 models have all five ratings · AHRI 217465953
Ducted, 2.5–3 tons88.0(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ducted air handler RAV-HB301BTP-UL209 of 230 models have all five ratings · AHRI 21641547779.8(50 is the typical model of its size class)A7CP21V36P-**Awith ducted air handler 7AH1AV42PX-113 of 113 models have all five ratings · AHRI 217465906
Ducted, 3.5–4.5 tons90.4(50 is the typical model of its size class) (higher)27VNA154A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 291VAN054**AA241 of 275 models have all five ratings · AHRI 21558791785.1(50 is the typical model of its size class)MHPC-H-048BMB120 of 120 models have all five ratings · AHRI 216497951
Ducted, 5 tons and up89.1(50 is the typical model of its size class) (higher)27VNA360A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAA81 of 101 models have all five ratings · AHRI 21593148466.7(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-5 of 5 models have all five ratings · AHRI 216371303
Non-ducted, up to 1.5 tons96.5(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ductless indoor unit 45MAHAQ06XA3Also sold as Arcoaire D5CSHAH06AAK51 of 54 models have all five ratings · AHRI 21532374292.6(50 is the typical model of its size class)MHPC-H-009BSBwith ductless indoor unit MCON-H-009BBB310 of 314 models have all five ratings · AHRI 216497938
Non-ducted, 2 tons88.5(50 is the typical model of its size class) (higher)37MARAQ24AA3with ductless indoor unit 45MAHAQ24XA3Also sold as Arcoaire D5CSRAH24AAK15 of 16 models have all five ratings · AHRI 21532375286.8(50 is the typical model of its size class)MHPC-H-024BSBwith ductless indoor unit MWAL-H-024BBB78 of 82 models have all five ratings · AHRI 216497919
Non-ducted, 2.5–3 tons91.0(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ductless indoor unit RAV-HB301UTP-UL29 of 30 models have all five ratings · AHRI 21641546575.1(50 is the typical model of its size class)GMV-V36WL/NHC-T(U)Also sold as Tosot TMV-V36WL/NHC-T(U)81 of 81 models have all five ratings · AHRI 217123443
Non-ducted, 3.5–4.5 tons84.9(50 is the typical model of its size class) (higher)MCY-MUB0488HS2P-UL20 of 22 models have all five ratings · AHRI 21676028868.6(50 is the typical model of its size class)MHPC-H-048BMB45 of 47 models have all five ratings · AHRI 216497952
Non-ducted, 5 tons and up69.0(50 is the typical model of its size class) (higher)MCY-MUB0608HS2P-UL4 of 4 models have all five ratings · AHRI 21676325168.8(50 is the typical model of its size class)GMV-V60WL/NHC-T(U)Also sold as Tosot TMV-V60WL/NHC-T(U)3 of 3 models have all five ratings · AHRI 216772249

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCarrierGree
COP at 5°Fbeats 100% · 2.50MCY-MUB0488HS2P-ULNon-ducted, 3.5–4.5 tonsbeats 99% · 2.40GMV-V36WL/NHC-T(U)Also sold as Tosot TMV-V36WL/NHC-T(U)Non-ducted, 2.5–3 tons
Capacity retention at 5°Fbeats 100% · 150%37MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 99% · 126%GK-H02TC/NHA-D(U)Also sold as Ac Pro PKHP-X-024VBC, Tosot TK-H02TC/NHA-D(U)Ducted, 2 tons
HSPF2beats 100% · 15.637MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 98% · 10.8SPHP-Z-V030BBDucted, 2.5–3 tons
SEER2beats 100% · 35.137MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 100% · 24.5GWH18AVEXF-D6DNA1A/OAlso sold as Kinghome KW18XQ29SDO, Tosot TW18HAY32A1DO, Tosot TW18HAY32A1DOC, Tosot TWH18AD32AO and 1 more; also listed as GWH18AVEXF-D6DNA1B/ODucted, up to 1.5 tons
EER2beats 100% · 17.2MCY-MUB0368HS2P-ULNon-ducted, 2.5–3 tonsbeats 100% · 14.5BH714S18P-**ADucted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 61,000 Btu/hH5H0V60*K*AAA*Ducted, 3.5–4.5 tonsbeats 99% · 30,300 Btu/hGK-H02TC/NHA-D(U)Also sold as Ac Pro PKHP-X-024VBC, Tosot TK-H02TC/NHA-D(U)Ducted, 2 tons

More comparisons