Skip to content

Carrier vs Gree heat pumps

Measured against models of the same size and duct type, Gree scores higher on 4 of the 6 ratings. Carrier has 846 outdoor models, Gree has 729 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Carrier and Gree on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Gree scores higher on 4 of the 6 ratings.
  • Carrier
  • Gree
  • Other ranked manufacturers
CarrierGree

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCarrierGree
Efficiency index49%median — · 23rd ranked54%median — · 14th ranked
COP at 5°F57% (higher)median 2.04 · 15th ranked44% (higher)median 1.94 · 25th ranked
Capacity retention at 5°F36%median 55% · 28th ranked57%median 77% · 9th ranked
HSPF241%median 7.8 · 24th ranked43%median 9.0 · 23rd ranked
SEER243%median 15.3 · 23rd ranked60%median 20.4 · 6th ranked
EER260% (higher)median 11.5 · 8th ranked59% (higher)median 12.0 · 10th ranked
Heating capacity at 5°F39%median 18,600 Btu/h · 27th ranked56%median 17,000 Btu/h · 13th ranked
Outdoor models846729
AHRI certifications589,0895,398

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCarrierGree
CEE 2025 Tier 1 (Split ASHP)41.8%354 models81.3%593 models
CEE 2026 Tier 1 (Split ASHP)37%313 models80.1%584 models
CEE Advanced Tier (Split ASHP)1.1%9 models5.5%40 models
Xcel Energy Colorado cold-climate ASHP (2025)29.1%246 models80.1%584 models
DOE Cold Climate Heat Pump Challenge1.1%9 models5.5%40 models
ENERGY STAR Cold Climate27.4%232 models65.4%477 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 10 groups where both have models
  • Carrier
  • Gree
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCarrierGree
Ducted, up to 1.5 tons76 · index 59%102 · index 65%
Ducted, 2 tons99 · index 47%69 · index 56%
Ducted, 2.5 to 3 tons232 · index 46%139 · index 52%
Ducted, 3.5 to 4.5 tons311 · index 45%121 · index 55%
Ducted, 5 tons and up69 · index 51%4 · index 60%
Non-ducted, up to 1.5 tons65 · index 60%316 · index 52%
Non-ducted, 2 tons18 · index 58%83 · index 56%
Non-ducted, 2.5 to 3 tons37 · index 56%81 · index 48%
Non-ducted, 3.5 to 4.5 tons25 · index 50%49 · index 47%
Non-ducted, 5 tons and up5 · index 58%3 · index 66%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCarrierCold-climate score, best modelGreeCold-climate score, best model
Ducted, up to 1.5 tons93.7(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK35 of 75 models qualify · AHRI 21532379885.9(50 is the typical model of its size class)SPHP-Z-V018BBwith ducted air handler AIRH-Z-V018V06C91 of 101 models qualify · AHRI 216497962
Ducted, 2 tons85.8(50 is the typical model of its size class) (higher)37MAHAQ24AA3with ducted air handler 45MBDAQ24XH3Also sold as Arcoaire D5CSHAH24AAK49 of 99 models qualify · AHRI 21532381777.1(50 is the typical model of its size class)MHPC-H-024BSBwith ducted air handler MDUC-H-024BBB71 of 86 models qualify · AHRI 216497934
Ducted, 2.5 to 3 tons83.6(50 is the typical model of its size class) (higher)37MGHAQ36EA3Also sold as Arcoaire D5CMHAH36EAK65 of 235 models qualify · AHRI 21535711977.7(50 is the typical model of its size class)SPHP-Z-V036BBwith ducted air handler AIRH-Z-V036V12C77 of 123 models qualify · AHRI 216497965
Ducted, 3.5 to 4.5 tons89.5(50 is the typical model of its size class) (higher)H5H0V48*K*AAA*with indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120A67 of 297 models qualify · AHRI 21837271488.7(50 is the typical model of its size class)GUD60W2/NHE-D(U)with ducted air handler HND60A/NHA-OAlso sold as Tosot TUH60-48D32E2O; also listed as FXU60HP230V1R32AO, HW60/NHE-D68 of 121 models qualify · AHRI 218043371
Ducted, 5 tons and up94.8(50 is the typical model of its size class) (higher)MCY-MUB0608HS2P-UL19 of 81 models qualify · AHRI 21676324966.7(50 is the typical model of its size class)GMV-V60WL/NHC-T(U)Also sold as Tosot TMV-V60WL/NHC-T(U)2 of 4 models qualify · AHRI 216772305
Non-ducted, up to 1.5 tons97.1(50 is the typical model of its size class) (higher)D5CPRAH18AAwith ductless indoor unit D5FPHAH18XAK42 of 65 models qualify · AHRI 21541321490.4(50 is the typical model of its size class)MHPC-H-009BSBwith ductless indoor unit MCON-H-009BBB298 of 316 models qualify · AHRI 216497938
Non-ducted, 2 tons90.1(50 is the typical model of its size class) (higher)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as Arcoaire D5CSHAH24AAK17 of 18 models qualify · AHRI 21532381585.7(50 is the typical model of its size class)MHPC-H-024BSBwith ductless indoor unit MWAL-H-024BBB68 of 83 models qualify · AHRI 216497919
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class) (higher)37MBHAQ36AA3with ductless indoor unit 45MCFAQ36XA3Also sold as Arcoaire D5CLHAH36AAK26 of 37 models qualify · AHRI 21532384377.8(50 is the typical model of its size class)GWHD(36)ND6MOAlso sold as Tosot TM36H32MO, Kinghome KM36X6O, Tosot MZ-COSMO36/O, Tosot TM36D6MO and 6 more; also listed as MUL36HP230V1R32AO, GS4M36HP230V1MO, GWHD(36)ND6CO74 of 81 models qualify · AHRI 214931589
Non-ducted, 3.5 to 4.5 tons75.6(50 is the typical model of its size class) (higher)37MGHAQ48FA3Also sold as Arcoaire D5CMHAH48FAK19 of 25 models qualify · AHRI 21535712367.0(50 is the typical model of its size class)GWHD(42)ND6MOAlso sold as Tosot TM42H32MO, Kinghome KM42X6O, Tosot TM42D6MO, Tosot TMSCI7H4R42 and 5 more; also listed as MUL42HP230V1R32AO, GS5M42HP230V1MO31 of 49 models qualify · AHRI 214931590
Non-ducted, 5 tons and up52.1(50 is the typical model of its size class)37VMB060HDS3-11 of 5 models qualify · AHRI 21636971453.8(50 is the typical model of its size class) (higher)GMV-V60WL/NHC-T(U)Also sold as Tosot TMV-V60WL/NHC-T(U)2 of 3 models qualify · AHRI 216772249

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCarrierAll-around score, best modelGreeAll-around score, best model
Ducted, up to 1.5 tons95.7(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK70 of 75 models have all five ratings · AHRI 21532379884.1(50 is the typical model of its size class)TWH09AUC25R32A1DOwith ducted air handler TM09R32SFDI101 of 101 models have all five ratings · AHRI 218214175
Ducted, 2 tons82.8(50 is the typical model of its size class) (higher)27VNA324A*030*with ducted air handler FE5BN(B,X)C36L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN024**AA, HEIL B5H3V24*K*AAA93 of 93 models have all five ratings · AHRI 21762425282.7(50 is the typical model of its size class)A7CP21V24P-**Awith ducted air handler 7AH2AE24PX-75 of 78 models have all five ratings · AHRI 217465953
Ducted, 2.5 to 3 tons88.0(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ducted air handler RAV-HB301BTP-UL216 of 237 models have all five ratings · AHRI 21641547779.7(50 is the typical model of its size class)A7CP21V36P-**Awith ducted air handler 7AH1AV42PX-130 of 130 models have all five ratings · AHRI 217465906
Ducted, 3.5 to 4.5 tons90.4(50 is the typical model of its size class) (higher)27VNA154A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 291VAN054**AA245 of 280 models have all five ratings · AHRI 21558791785.3(50 is the typical model of its size class)MHPC-H-048BMB117 of 121 models have all five ratings · AHRI 216497951
Ducted, 5 tons and up89.3(50 is the typical model of its size class) (higher)27VNA360A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAA82 of 102 models have all five ratings · AHRI 21593148467.2(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-5 of 5 models have all five ratings · AHRI 216371303
Non-ducted, up to 1.5 tons96.9(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ductless indoor unit 45MAHAQ06XA3Also sold as Arcoaire D5CSHAH06AAK61 of 65 models have all five ratings · AHRI 21532374293.3(50 is the typical model of its size class)MHPC-H-009BSBwith ductless indoor unit MCON-H-009BBB316 of 316 models have all five ratings · AHRI 216497938
Non-ducted, 2 tons89.4(50 is the typical model of its size class) (higher)37MARAQ24AA3with ductless indoor unit 45MAHAQ24XA3Also sold as Arcoaire D5CSRAH24AAK17 of 18 models have all five ratings · AHRI 21532375287.8(50 is the typical model of its size class)MHPC-H-024BSBwith ductless indoor unit MWAL-H-024BBB79 of 83 models have all five ratings · AHRI 216497919
Non-ducted, 2.5 to 3 tons91.1(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ductless indoor unit RAV-HB301UTP-UL36 of 37 models have all five ratings · AHRI 21641546575.5(50 is the typical model of its size class)GMV-V36WL/NHC-T(U)Also sold as Tosot TMV-V36WL/NHC-T(U)81 of 81 models have all five ratings · AHRI 217123443
Non-ducted, 3.5 to 4.5 tons84.9(50 is the typical model of its size class) (higher)MCY-MUB0488HS2P-UL21 of 25 models have all five ratings · AHRI 21676028868.7(50 is the typical model of its size class)MHPC-H-048BMB48 of 49 models have all five ratings · AHRI 216497952
Non-ducted, 5 tons and up69.5(50 is the typical model of its size class)MCY-MUB0608HS2P-UL5 of 5 models have all five ratings · AHRI 21676325169.5(50 is the typical model of its size class)GMV-V60WL/NHC-T(U)Also sold as Tosot TMV-V60WL/NHC-T(U)3 of 3 models have all five ratings · AHRI 216772249

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCarrierGree
COP at 5°Fbeats 100% · 2.50MCY-MUB0488HS2P-ULNon-ducted, 3.5 to 4.5 tonsbeats 99% · 2.35GFH60DCXL-D6DND4C/ONon-ducted, 3.5 to 4.5 tons
Capacity retention at 5°Fbeats 100% · 150%37MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 99% · 103%SPHP-X-I060BDucted, 3.5 to 4.5 tons
HSPF2beats 100% · 15.637MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 98% · 13.9MHPC-H-009BSBNon-ducted, up to 1.5 tons
SEER2beats 100% · 35.137MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 100% · 24.5GWH18AVEXF-D6DNA1A/OAlso sold as Kinghome KW18XQ29SDO, Tosot TW18HAY32A1DO, Tosot TW18HAY32A1DOC, Tosot TWH18AD32AO and 1 more; also listed as GWH18AVEXF-D6DNA1B/ODucted, up to 1.5 tons
EER2beats 100% · 17.2MCY-MUB0368HS2P-ULNon-ducted, 2.5 to 3 tonsbeats 100% · 14.5BH714S18P-**ADucted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 61,000 Btu/hH5H0V60*K*AAA*Ducted, 3.5 to 4.5 tonsbeats 98% · 19,600 Btu/hGS18HP230V1CLODucted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Carrier vs Gree: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Carrier (median, middle 50%)
  • Gree (median, middle 50%)
Heating capacity, % of its 47°F maximum70%70%COP at maximum capacity2.021.95

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Carrier: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Carrier, 47°F256100%100%100%100%100%
Carrier, 17°F25665%71%78%85%91%
Carrier, 5°F25657%62%70%78%82%
Carrier: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Carrier, 47°F2562.873.093.233.523.63
Carrier, 17°F2562.122.242.382.522.65
Carrier, 5°F2561.851.992.022.152.32
Gree: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Gree, 47°F550100%100%100%100%100%
Gree, 17°F55068%73%79%87%95%
Gree, 5°F55058%63%70%76%94%
Gree: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Gree, 47°F5502.873.173.283.423.61
Gree, 17°F5501.992.082.252.42.56
Gree, 5°F5501.81.831.952.052.14

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter