Skip to content

Carrier vs Midea heat pumps

Measured against models of the same size and duct type, Midea scores higher on 5 of the 6 ratings. Carrier has 846 outdoor models, Midea has 555 outdoor models. They share hardware: 213 equipment families appear under both names.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Carrier and Midea on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Midea scores higher on 5 of the 6 ratings.
  • Carrier
  • Midea
  • Other ranked manufacturers
CarrierMidea

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCarrierMidea
Efficiency index49%median — · 23rd ranked60%median — · 7th ranked
COP at 5°F57%median 2.04 · 15th ranked60%median 2.00 · 8th ranked
Capacity retention at 5°F36%median 55% · 28th ranked57%median 74% · 10th ranked
HSPF241%median 7.8 · 24th ranked66%median 9.5 · 6th ranked
SEER243%median 15.3 · 23rd ranked61%median 19.5 · 5th ranked
EER260% (higher)median 11.5 · 8th ranked55% (higher)median 11.7 · 13th ranked
Heating capacity at 5°F39%median 18,600 Btu/h · 27th ranked60%median 20,000 Btu/h · 10th ranked
Outdoor models846555
AHRI certifications589,0896,788

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCarrierMidea
CEE 2025 Tier 1 (Split ASHP)41.8%354 models75.3%418 models
CEE 2026 Tier 1 (Split ASHP)37%313 models74.2%412 models
CEE Advanced Tier (Split ASHP)1.1%9 models3.4%19 models
Xcel Energy Colorado cold-climate ASHP (2025)29.1%246 models69.7%387 models
DOE Cold Climate Heat Pump Challenge1.1%9 models3.4%19 models
ENERGY STAR Cold Climate27.4%232 models64%355 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 10 groups where both have models
  • Carrier
  • Midea
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCarrierMidea
Ducted, up to 1.5 tons76 · index 59%80 · index 75%
Ducted, 2 tons99 · index 47%57 · index 62%
Ducted, 2.5 to 3 tons232 · index 46%122 · index 61%
Ducted, 3.5 to 4.5 tons311 · index 45%110 · index 63%
Ducted, 5 tons and up69 · index 51%22 · index 63%
Non-ducted, up to 1.5 tons65 · index 60%185 · index 57%
Non-ducted, 2 tons18 · index 58%50 · index 53%
Non-ducted, 2.5 to 3 tons37 · index 56%94 · index 56%
Non-ducted, 3.5 to 4.5 tons25 · index 50%64 · index 49%
Non-ducted, 5 tons and up5 · index 58%15 · index 45%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCarrierCold-climate score, best modelMideaCold-climate score, best model
Ducted, up to 1.5 tons93.7(50 is the typical model of its size class)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK35 of 75 models qualify · AHRI 21532379893.7(50 is the typical model of its size class)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK71 of 81 models qualify · AHRI 215324042
Ducted, 2 tons85.8(50 is the typical model of its size class)37MAHAQ24AA3with ducted air handler 45MBDAQ24XH3Also sold as Arcoaire D5CSHAH24AAK49 of 99 models qualify · AHRI 21532381785.8(50 is the typical model of its size class)37MAHAQ24AA3with ducted air handler 45MBDAQ24XH3Also sold as MDV MOD30-24HFN10-M1X; also listed as D5CSHAH24AAK49 of 54 models qualify · AHRI 215324061
Ducted, 2.5 to 3 tons83.6(50 is the typical model of its size class)37MGHAQ36EA3Also sold as Arcoaire D5CMHAH36EAK65 of 235 models qualify · AHRI 21535711990.3(50 is the typical model of its size class) (higher)M4OD31-27HFN8-M1XD92 of 126 models qualify · AHRI 218083250
Ducted, 3.5 to 4.5 tons89.5(50 is the typical model of its size class) (higher)H5H0V48*K*AAA*with indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120A67 of 297 models qualify · AHRI 21837271483.9(50 is the typical model of its size class)MOVA-60HDN10-M20Gwith ducted air handler MVME60C2MN10TAAlso listed as MOVC-60HDN10-M20G91 of 106 models qualify · AHRI 214814477
Ducted, 5 tons and up94.8(50 is the typical model of its size class) (higher)MCY-MUB0608HS2P-UL19 of 81 models qualify · AHRI 21676324967.0(50 is the typical model of its size class)MDV-V60WMN10TAlso listed as MDV-V60WMN10T(B)6 of 24 models qualify · AHRI 216021062
Non-ducted, up to 1.5 tons97.1(50 is the typical model of its size class)D5CPRAH18AAwith ductless indoor unit D5FPHAH18XAK42 of 65 models qualify · AHRI 21541321497.7(50 is the typical model of its size class) (higher)MOX230-06HFN10-M1with ductless indoor unit MSEPB-06HRFN10-M1125 of 185 models qualify · AHRI 215865890
Non-ducted, 2 tons90.1(50 is the typical model of its size class)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as Arcoaire D5CSHAH24AAK17 of 18 models qualify · AHRI 21532381590.1(50 is the typical model of its size class)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as MDV MOD30-24HFN10-M1X; also listed as D5CSHAH24AAK44 of 50 models qualify · AHRI 215324059
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class)37MBHAQ36AA3with ductless indoor unit 45MCFAQ36XA3Also sold as Arcoaire D5CLHAH36AAK26 of 37 models qualify · AHRI 21532384389.4(50 is the typical model of its size class)37MBHAQ36AA3with ductless indoor unit 45MCFAQ36XA3Also sold as MDV MOX630-36HFN10-M2X; also listed as D5CLHAH36AAK78 of 94 models qualify · AHRI 215324087
Non-ducted, 3.5 to 4.5 tons75.6(50 is the typical model of its size class)37MGHAQ48FA3Also sold as Arcoaire D5CMHAH48FAK19 of 25 models qualify · AHRI 21535712375.6(50 is the typical model of its size class)D5CMHAH48FAKAlso sold as MDV M6OE31-48HFN10-M1XD, MDV M6OE31-48HFN10-M1X; also listed as 37MGHAQ48FA357 of 64 models qualify · AHRI 215357417
Non-ducted, 5 tons and up52.1(50 is the typical model of its size class)37VMB060HDS3-11 of 5 models qualify · AHRI 21636971452.1(50 is the typical model of its size class)MDV-V60WMN10TAlso listed as MDV-V60WMN10T(B)3 of 15 models qualify · AHRI 216021081

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCarrierAll-around score, best modelMideaAll-around score, best model
Ducted, up to 1.5 tons95.7(50 is the typical model of its size class)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK70 of 75 models have all five ratings · AHRI 21532379895.7(50 is the typical model of its size class)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK83 of 83 models have all five ratings · AHRI 215324042
Ducted, 2 tons82.8(50 is the typical model of its size class)27VNA324A*030*with ducted air handler FE5BN(B,X)C36L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN024**AA, HEIL B5H3V24*K*AAA93 of 93 models have all five ratings · AHRI 21762425290.0(50 is the typical model of its size class) (higher)MOD30-24HFN10-M1Hwith ducted air handler MSEPD-24HRFN10-M1H55 of 55 models have all five ratings · AHRI 217998293
Ducted, 2.5 to 3 tons88.0(50 is the typical model of its size class)RAV-BP301AT2P-ULwith ducted air handler RAV-HB301BTP-UL216 of 237 models have all five ratings · AHRI 21641547791.8(50 is the typical model of its size class) (higher)M4OD31-27HFN8-M1XD121 of 121 models have all five ratings · AHRI 218083250
Ducted, 3.5 to 4.5 tons90.4(50 is the typical model of its size class) (higher)27VNA154A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 291VAN054**AA245 of 280 models have all five ratings · AHRI 21558791786.0(50 is the typical model of its size class)D5CMRAH48FAKAlso sold as MDV M6OE30-48HFN10-M1D, MDV M6OE30-48HFN10-M1; also listed as 37MGRAQ48FA3110 of 110 models have all five ratings · AHRI 215357445
Ducted, 5 tons and up89.3(50 is the typical model of its size class) (higher)27VNA360A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAA82 of 102 models have all five ratings · AHRI 21593148470.5(50 is the typical model of its size class)MRD-60HWD1N10-M18GAlso listed as MRD-60HWD1N10-M18GB22 of 22 models have all five ratings · AHRI 215894250
Non-ducted, up to 1.5 tons96.9(50 is the typical model of its size class)37MAHAQ06AA3with ductless indoor unit 45MAHAQ06XA3Also sold as Arcoaire D5CSHAH06AAK61 of 65 models have all five ratings · AHRI 21532374296.9(50 is the typical model of its size class)37MAHAQ06AA3with ductless indoor unit D5MAHAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK176 of 185 models have all five ratings · AHRI 215323786
Non-ducted, 2 tons89.4(50 is the typical model of its size class)37MARAQ24AA3with ductless indoor unit 45MAHAQ24XA3Also sold as Arcoaire D5CSRAH24AAK17 of 18 models have all five ratings · AHRI 21532375289.4(50 is the typical model of its size class)37MARAQ24AA3with ductless indoor unit D5MAHAQ24XA3Also sold as MDV MOD30-24HFN10-M1; also listed as D5CSRAH24AAK46 of 50 models have all five ratings · AHRI 215323796
Non-ducted, 2.5 to 3 tons91.1(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ductless indoor unit RAV-HB301UTP-UL36 of 37 models have all five ratings · AHRI 21641546589.4(50 is the typical model of its size class)M4OD31-27HFN8-M1XD93 of 94 models have all five ratings · AHRI 218083249
Non-ducted, 3.5 to 4.5 tons84.9(50 is the typical model of its size class) (higher)MCY-MUB0488HS2P-UL21 of 25 models have all five ratings · AHRI 21676028876.6(50 is the typical model of its size class)D5CMHAH48FAKAlso sold as MDV M6OE31-48HFN10-M1XD, MDV M6OE31-48HFN10-M1X; also listed as 37MGHAQ48FA363 of 64 models have all five ratings · AHRI 215357415
Non-ducted, 5 tons and up69.5(50 is the typical model of its size class) (higher)MCY-MUB0608HS2P-UL5 of 5 models have all five ratings · AHRI 21676325161.8(50 is the typical model of its size class)D5CMRAH55FAKAlso sold as MDV M6OE30-60HFN10-M1D, MDV M6OE30-60HFN10-M1; also listed as 37MGRAQ55FA315 of 15 models have all five ratings · AHRI 215357450

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCarrierMidea
COP at 5°Fbeats 100% · 2.50MCY-MUB0488HS2P-ULNon-ducted, 3.5 to 4.5 tonsbeats 99% · 2.5137MARAQ12AA3Also sold as MDV MOX230-12HFN10-M1; also listed as D5CSRAH12AAKNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 100% · 150%37MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 100% · 150%37MPRAQ06AA3Also sold as MDV MOX430-06HFN10-M1HNon-ducted, up to 1.5 tons
HSPF2beats 100% · 15.637MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 100% · 15.637MPRAQ06AA3Also sold as MDV MOX430-06HFN10-M1HNon-ducted, up to 1.5 tons
SEER2beats 100% · 35.137MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 100% · 27.0MOX430-15HFN10-M1HDucted, up to 1.5 tons
EER2beats 100% · 17.2MCY-MUB0368HS2P-ULNon-ducted, 2.5 to 3 tonsbeats 100% · 18.1MOX230-06HFN10-M1Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 61,000 Btu/hH5H0V60*K*AAA*Ducted, 3.5 to 4.5 tonsbeats 100% · 55,000 Btu/hMOVA-60HDN10-M20GAlso listed as MOVC-60HDN10-M20GDucted, 3.5 to 4.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Carrier vs Midea: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Carrier (median, middle 50%)
  • Midea (median, middle 50%)
Heating capacity, % of its 47°F maximum70%66%COP at maximum capacity2.022.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Carrier: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Carrier, 47°F256100%100%100%100%100%
Carrier, 17°F25665%71%78%85%91%
Carrier, 5°F25657%62%70%78%82%
Carrier: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Carrier, 47°F2562.873.093.233.523.63
Carrier, 17°F2562.122.242.382.522.65
Carrier, 5°F2561.851.992.022.152.32
Midea: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Midea, 47°F502100%100%100%100%100%
Midea, 17°F50264%68%73%81%85%
Midea, 5°F50257%62%66%77%82%
Midea: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Midea, 47°F5022.883.13.243.493.61
Midea, 17°F5022.12.222.32.492.62
Midea, 5°F5021.851.9922.112.31

Source: NEEP ccASHP list · as of

More comparisons