Both views use the same certified data. This device remembers your choice.
Ephoca vs Gree heat pumps
Measured against models of the same size and duct type, Gree scores higher on 6 of the 6 ratings. Ephoca has 382 outdoor models, Gree has 729 outdoor models. Ephoca has no QMID on file and is not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Ephoca
- Gree
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Ephoca | Gree |
|---|---|---|
| Efficiency index | 32%median — | 54%median — · 14th ranked |
| COP at 5°F | 22%median 1.75 | 44%median 1.94 · 25th ranked |
| Capacity retention at 5°F | 51%median 73% | 57%median 77% · 9th ranked |
| HSPF2 | 41%median 9.2 | 43%median 9.0 · 23rd ranked |
| SEER2 | 22%median 15.2 | 60%median 20.4 · 6th ranked |
| EER2 | 30%median 11.0 | 59%median 12.0 · 10th ranked |
| Heating capacity at 5°F | 21%median 6,500 Btu/h | 56%median 17,000 Btu/h · 13th ranked |
| Outdoor models | 382 | 729 |
| AHRI certifications | 382 | 5,398 |
Share of models meeting each standard
| Standard | Ephoca | Gree |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 81.3%593 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 80.1%584 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 5.5%40 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 31.4%120 models | 80.1%584 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 5.5%40 models |
| ENERGY STAR Cold Climate | 48.7%186 models | 65.4%477 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Ephoca
- Gree
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Ephoca | Gree |
|---|---|---|
| Ducted, up to 1.5 tons | 316 · index 34% | 102 · index 65% |
| Ducted, 2 tons | None | 69 · index 56% |
| Ducted, 2.5 to 3 tons | None | 139 · index 52% |
| Ducted, 3.5 to 4.5 tons | None | 121 · index 55% |
| Ducted, 5 tons and up | None | 4 · index 60% |
| Non-ducted, up to 1.5 tons | 66 · index 23% | 316 · index 52% |
| Non-ducted, 2 tons | None | 83 · index 56% |
| Non-ducted, 2.5 to 3 tons | None | 81 · index 48% |
| Non-ducted, 3.5 to 4.5 tons | None | 49 · index 47% |
| Non-ducted, 5 tons and up | None | 3 · index 66% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | EphocaCold-climate score, best model | GreeCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 61.5(50 is the typical model of its size class)AVK09R3H2Also listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 more270 of 316 models qualify · AHRI 217607099 | 85.9(50 is the typical model of its size class) (higher)SPHP-Z-V018BBwith ducted air handler AIRH-Z-V018V06C91 of 101 models qualify · AHRI 216497962 |
| Ducted, 2 tons | No models in this size class | 77.1(50 is the typical model of its size class)MHPC-H-024BSBwith ducted air handler MDUC-H-024BBB71 of 86 models qualify · AHRI 216497934 |
| Ducted, 2.5 to 3 tons | No models in this size class | 77.7(50 is the typical model of its size class)SPHP-Z-V036BBwith ducted air handler AIRH-Z-V036V12C77 of 123 models qualify · AHRI 216497965 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 88.7(50 is the typical model of its size class)GUD60W2/NHE-D(U)with ducted air handler HND60A/NHA-OAlso sold as Tosot TUH60-48D32E2O; also listed as FXU60HP230V1R32AO, HW60/NHE-D68 of 121 models qualify · AHRI 218043371 |
| Ducted, 5 tons and up | No models in this size class | 66.7(50 is the typical model of its size class)GMV-V60WL/NHC-T(U)Also sold as Tosot TMV-V60WL/NHC-T(U)2 of 4 models qualify · AHRI 216772305 |
| Non-ducted, up to 1.5 tons | 33.6(50 is the typical model of its size class)AWP09R3H1Also listed as AWP09N3H1, AWP09R3H2, AWP09N3H2, AWE09R3H2 and 35 more66 of 66 models qualify · AHRI 217677964 | 90.4(50 is the typical model of its size class) (higher)MHPC-H-009BSBwith ductless indoor unit MCON-H-009BBB298 of 316 models qualify · AHRI 216497938 |
| Non-ducted, 2 tons | No models in this size class | 85.7(50 is the typical model of its size class)MHPC-H-024BSBwith ductless indoor unit MWAL-H-024BBB68 of 83 models qualify · AHRI 216497919 |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 77.8(50 is the typical model of its size class)GWHD(36)ND6MOAlso sold as Tosot TM36H32MO, Kinghome KM36X6O, Tosot MZ-COSMO36/O, Tosot TM36D6MO and 6 more; also listed as MUL36HP230V1R32AO, GS4M36HP230V1MO, GWHD(36)ND6CO74 of 81 models qualify · AHRI 214931589 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 67.0(50 is the typical model of its size class)GWHD(42)ND6MOAlso sold as Tosot TM42H32MO, Kinghome KM42X6O, Tosot TM42D6MO, Tosot TMSCI7H4R42 and 5 more; also listed as MUL42HP230V1R32AO, GS5M42HP230V1MO31 of 49 models qualify · AHRI 214931590 |
| Non-ducted, 5 tons and up | No models in this size class | 53.8(50 is the typical model of its size class)GMV-V60WL/NHC-T(U)Also sold as Tosot TMV-V60WL/NHC-T(U)2 of 3 models qualify · AHRI 216772249 |
All-around best
| Size and duct type | EphocaAll-around score, best model | GreeAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 55.4(50 is the typical model of its size class)AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 more316 of 316 models have all five ratings · AHRI 217650520 | 84.1(50 is the typical model of its size class) (higher)TWH09AUC25R32A1DOwith ducted air handler TM09R32SFDI101 of 101 models have all five ratings · AHRI 218214175 |
| Ducted, 2 tons | No models in this size class | 82.7(50 is the typical model of its size class)A7CP21V24P-**Awith ducted air handler 7AH2AE24PX-75 of 78 models have all five ratings · AHRI 217465953 |
| Ducted, 2.5 to 3 tons | No models in this size class | 79.7(50 is the typical model of its size class)A7CP21V36P-**Awith ducted air handler 7AH1AV42PX-130 of 130 models have all five ratings · AHRI 217465906 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 85.3(50 is the typical model of its size class)MHPC-H-048BMB117 of 121 models have all five ratings · AHRI 216497951 |
| Ducted, 5 tons and up | No models in this size class | 67.2(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-5 of 5 models have all five ratings · AHRI 216371303 |
| Non-ducted, up to 1.5 tons | 23.7(50 is the typical model of its size class)APP10*3*1with ductless indoor unit APP10*3*1Also listed as APP10*3*2, APK10*3*2, APP10N4H1, APP10N3H1 and 9 more66 of 66 models have all five ratings · AHRI 213607325 | 93.3(50 is the typical model of its size class) (higher)MHPC-H-009BSBwith ductless indoor unit MCON-H-009BBB316 of 316 models have all five ratings · AHRI 216497938 |
| Non-ducted, 2 tons | No models in this size class | 87.8(50 is the typical model of its size class)MHPC-H-024BSBwith ductless indoor unit MWAL-H-024BBB79 of 83 models have all five ratings · AHRI 216497919 |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 75.5(50 is the typical model of its size class)GMV-V36WL/NHC-T(U)Also sold as Tosot TMV-V36WL/NHC-T(U)81 of 81 models have all five ratings · AHRI 217123443 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 68.7(50 is the typical model of its size class)MHPC-H-048BMB48 of 49 models have all five ratings · AHRI 216497952 |
| Non-ducted, 5 tons and up | No models in this size class | 69.5(50 is the typical model of its size class)GMV-V60WL/NHC-T(U)Also sold as Tosot TMV-V60WL/NHC-T(U)3 of 3 models have all five ratings · AHRI 216772249 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Ephoca | Gree |
|---|---|---|
| COP at 5°F | beats 70% · 2.01AVP20R3H1-2Also listed as AVP20R4H1, AVP20N4H1, AVP20R3H1, AVP20N3H1 and 18 moreDucted, up to 1.5 tons | beats 99% · 2.35GFH60DCXL-D6DND4C/ONon-ducted, 3.5 to 4.5 tons |
| Capacity retention at 5°F | beats 86% · 95%AVK09R3H2Also listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 moreDucted, up to 1.5 tons | beats 99% · 103%SPHP-X-I060BDucted, 3.5 to 4.5 tons |
| HSPF2 | beats 69% · 9.9AVP10*3*1Also listed as AVP10*3*2, AVE10*3*2, AVK10*3*2, AXP10*3*1 and 35 moreDucted, up to 1.5 tons | beats 98% · 13.9MHPC-H-009BSBNon-ducted, up to 1.5 tons |
| SEER2 | beats 45% · 15.4AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons | beats 100% · 24.5GWH18AVEXF-D6DNA1A/OAlso sold as Kinghome KW18XQ29SDO, Tosot TW18HAY32A1DO, Tosot TW18HAY32A1DOC, Tosot TWH18AD32AO and 1 more; also listed as GWH18AVEXF-D6DNA1B/ODucted, up to 1.5 tons |
| EER2 | beats 55% · 11.7AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons | beats 100% · 14.5BH714S18P-**ADucted, up to 1.5 tons |
| Heating capacity at 5°F | beats 68% · 12,000 Btu/hAVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons | beats 98% · 19,600 Btu/hGS18HP230V1CLODucted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Ephoca (median, middle 50%)
- Gree (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ephoca, 47°F | 174 | 100% | 100% | 100% | 100% | 100% |
| Ephoca, 17°F | 174 | 60% | 60% | 65% | 69% | 73% |
| Ephoca, 5°F | 174 | 48% | 56% | 57% | 58% | 67% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ephoca, 47°F | 174 | 2.75 | 2.84 | 2.84 | 3.46 | 3.47 |
| Ephoca, 17°F | 174 | 1.91 | 2.02 | 2.02 | 2.32 | 2.33 |
| Ephoca, 5°F | 174 | 1.75 | 1.75 | 1.75 | 1.75 | 1.95 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Gree, 47°F | 550 | 100% | 100% | 100% | 100% | 100% |
| Gree, 17°F | 550 | 68% | 73% | 79% | 87% | 95% |
| Gree, 5°F | 550 | 58% | 63% | 70% | 76% | 94% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Gree, 47°F | 550 | 2.87 | 3.17 | 3.28 | 3.42 | 3.61 |
| Gree, 17°F | 550 | 1.99 | 2.08 | 2.25 | 2.4 | 2.56 |
| Gree, 5°F | 550 | 1.8 | 1.83 | 1.95 | 2.05 | 2.14 |
Source: NEEP ccASHP list · as of