Skip to content

ApooDr vs Aprodr heat pumps

Measured against models of the same size and duct type, Aprodr scores higher on 4 of the 6 ratings. ApooDr has 44 outdoor models, Aprodr has 44 outdoor models. ApooDr and Aprodr have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ApooDr and Aprodr on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Aprodr scores higher on 4 of the 6 ratings.
  • ApooDr
  • Aprodr
  • Other ranked manufacturers
ApooDrAprodr

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingApooDrAprodr
Efficiency index58%median —59%median —
COP at 5°F64%median 2.0165%median 2.04
Capacity retention at 5°F45%median 71%45%median 72%
HSPF265%median 9.666%median 9.8
SEER264%median 20.165%median 20.1
EER253%median 12.054%median 12.0
Heating capacity at 5°F52%median 17,950 Btu/h52%median 18,200 Btu/h
Outdoor models4444
AHRI certifications6167

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardApooDrAprodr
CEE 2025 Tier 1 (Split ASHP)90.9%40 models90.9%40 models
CEE 2026 Tier 1 (Split ASHP)86.4%38 models86.4%38 models
CEE Advanced Tier (Split ASHP)0%0 models2.3%1 models
Xcel Energy Colorado cold-climate ASHP (2025)75%33 models75%33 models
DOE Cold Climate Heat Pump Challenge0%0 models2.3%1 models
ENERGY STAR Cold Climate77.3%34 models77.3%34 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 10 groups where both have models
  • ApooDr
  • Aprodr
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeApooDrAprodr
Ducted, up to 1.5 tons5 · index 70%6 · index 72%
Ducted, 2 tons4 · index 67%4 · index 67%
Ducted, 2.5–3 tons6 · index 61%6 · index 61%
Ducted, 3.5–4.5 tons7 · index 64%6 · index 62%
Ducted, 5 tons and up2 · index 64%2 · index 64%
Non-ducted, up to 1.5 tons19 · index 58%19 · index 59%
Non-ducted, 2 tons5 · index 51%5 · index 55%
Non-ducted, 2.5–3 tons4 · index 42%4 · index 42%
Non-ducted, 3.5–4.5 tons2 · index 43%2 · index 43%
Non-ducted, 5 tons and up1 · index 27%1 · index 27%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeApooDrCold-climate score, best modelAprodrCold-climate score, best model
Ducted, up to 1.5 tons81.3(50 is the typical model of its size class)ALC24-09H1Bwith ducted air handler DIU-09HWFN104 of 5 models qualify · AHRI 21756349285.5(50 is the typical model of its size class) (higher)AHU3G-18HFN-Bwith ducted air handler AHU3G-18HFN-A5 of 6 models qualify · AHRI 218045630
Ducted, 2 tons77.1(50 is the typical model of its size class)ALC24-24H1Bwith ducted air handler DIU-24HWFN104 of 4 models qualify · AHRI 21756349577.1(50 is the typical model of its size class)ALC24-24H1Bwith ducted air handler DIU-24HWFN104 of 4 models qualify · AHRI 218035853
Ducted, 2.5–3 tons77.4(50 is the typical model of its size class)AHU3G-36HFN-Bwith ducted air handler AHU3G-36HFN-A4 of 6 models qualify · AHRI 21756347577.4(50 is the typical model of its size class)AHU3G-36HFN-Bwith ducted air handler AHU3G-36HFN-A4 of 6 models qualify · AHRI 218045636
Ducted, 3.5–4.5 tons77.9(50 is the typical model of its size class)AM6OG-48HFN17 of 7 models qualify · AHRI 21756351577.9(50 is the typical model of its size class)AM6OG-48HFN16 of 6 models qualify · AHRI 217334325
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)None on this board (0 of 2 models qualify)
Non-ducted, up to 1.5 tons84.7(50 is the typical model of its size class)ASG24-09H220V1Bwith ductless indoor unit ASG24-09H220V1A15 of 19 models qualify · AHRI 21756348885.9(50 is the typical model of its size class) (higher)ASG24-09H220V1Bwith ductless indoor unit ASG24-09H220V1A15 of 19 models qualify · AHRI 218035846
Non-ducted, 2 tons73.7(50 is the typical model of its size class)ALC24-24H1Bwith ductless indoor unit CCA22-24HRFN15 of 5 models qualify · AHRI 21756350273.7(50 is the typical model of its size class)ALC24-24H1Bwith ductless indoor unit CCA22-24HRFN15 of 5 models qualify · AHRI 218035858
Non-ducted, 2.5–3 tons62.8(50 is the typical model of its size class)ALC24-36H1Bwith ductless indoor unit CCA22-36HRFN12 of 4 models qualify · AHRI 21756350362.8(50 is the typical model of its size class)ALC24-36H1Bwith ductless indoor unit CCA22-36HRFN12 of 4 models qualify · AHRI 218035859
Non-ducted, 3.5–4.5 tons60.1(50 is the typical model of its size class)AM6OG-48HFN12 of 2 models qualify · AHRI 21756351660.1(50 is the typical model of its size class)AM6OG-48HFN12 of 2 models qualify · AHRI 217334326
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeApooDrAll-around score, best modelAprodrAll-around score, best model
Ducted, up to 1.5 tons80.8(50 is the typical model of its size class)ALC24-09H1Bwith ducted air handler DIU-09HWFN105 of 5 models have all five ratings · AHRI 21756349280.8(50 is the typical model of its size class)ALC24-09H1Bwith ducted air handler DIU-09HWFN106 of 6 models have all five ratings · AHRI 218035850
Ducted, 2 tons78.8(50 is the typical model of its size class)ALC24-24H1Bwith ducted air handler DIU-24HWFN104 of 4 models have all five ratings · AHRI 21756349578.8(50 is the typical model of its size class)ALC24-24H1Bwith ducted air handler DIU-24HWFN104 of 4 models have all five ratings · AHRI 218035853
Ducted, 2.5–3 tons74.9(50 is the typical model of its size class)AHU3G-36HFN-Bwith ducted air handler AHU3G-36HFN-A6 of 6 models have all five ratings · AHRI 21756347574.9(50 is the typical model of its size class)AHU3G-36HFN-Bwith ducted air handler AHU3G-36HFN-A6 of 6 models have all five ratings · AHRI 218045636
Ducted, 3.5–4.5 tons85.1(50 is the typical model of its size class)AM6OG-48HFN17 of 7 models have all five ratings · AHRI 21756351585.1(50 is the typical model of its size class)AM6OG-48HFN16 of 6 models have all five ratings · AHRI 217334325
Ducted, 5 tons and up65.3(50 is the typical model of its size class)ALC24-60H1Bwith ducted air handler DIU-60HWFN102 of 2 models have all five ratings · AHRI 21756349865.3(50 is the typical model of its size class)ALC24-60H1Bwith ducted air handler DIU-60HWFN102 of 2 models have all five ratings · AHRI 218035870
Non-ducted, up to 1.5 tons85.6(50 is the typical model of its size class)ASG24-09H220V1Bwith ductless indoor unit ASG24-09H220V1A19 of 19 models have all five ratings · AHRI 21756348886.7(50 is the typical model of its size class) (higher)ASG24-09H220V1Bwith ductless indoor unit ASG24-09H220V1A19 of 19 models have all five ratings · AHRI 218035846
Non-ducted, 2 tons66.2(50 is the typical model of its size class)ALC24-24H1Bwith ductless indoor unit CCA22-24HRFN15 of 5 models have all five ratings · AHRI 21756350274.3(50 is the typical model of its size class) (higher)ASG24-24H1Bwith ductless indoor unit ASG24-24H1A5 of 5 models have all five ratings · AHRI 218035849
Non-ducted, 2.5–3 tons58.3(50 is the typical model of its size class)AM5OG-36HFN14 of 4 models have all five ratings · AHRI 21756351158.3(50 is the typical model of its size class)AM5OG-36HFN14 of 4 models have all five ratings · AHRI 217334321
Non-ducted, 3.5–4.5 tons52.8(50 is the typical model of its size class)AM6OG-48HFN12 of 2 models have all five ratings · AHRI 21756351652.8(50 is the typical model of its size class)AM6OG-48HFN12 of 2 models have all five ratings · AHRI 217334326
Non-ducted, 5 tons and up32.5(50 is the typical model of its size class)AM6OG-55HFN11 of 1 models have all five ratings · AHRI 21756351732.5(50 is the typical model of its size class)AM6OG-55HFN11 of 1 models have all five ratings · AHRI 217334327

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingApooDrAprodr
COP at 5°Fbeats 99% · 2.51ALC24-12H1BNon-ducted, up to 1.5 tonsbeats 99% · 2.51ALC24-12H1BNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 94% · 100%AHU3G-48HFN-BDucted, 3.5–4.5 tonsbeats 95% · 103%AHU3G-18HFN-BDucted, up to 1.5 tons
HSPF2beats 98% · 10.8AHU3G-30HFN-BDucted, 2.5–3 tonsbeats 98% · 10.8AHU3G-30HFN-BDucted, 2.5–3 tons
SEER2beats 96% · 20.4AM6OG-48HFN1Ducted, 3.5–4.5 tonsbeats 96% · 20.4AM6OG-48HFN1Ducted, 3.5–4.5 tons
EER2beats 91% · 13.3ALC24-18H1BDucted, up to 1.5 tonsbeats 91% · 15.0ASG24-09H1BNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 54,000 Btu/hAHU3G-50HFN-BAlso listed as AHU3G-60HFN-BDucted, 3.5–4.5 tonsbeats 98% · 54,000 Btu/hAHU3G-60HFN-BDucted, 3.5–4.5 tons

More comparisons