LG heat pump efficiency: 108 outdoor models compared
LG has 108 heat pump outdoor models certified with this refrigerant group, in 1,742 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes LG makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 108
- AHRI certifications
- 1,742
- Efficiency index
- 58%
- Typical model vs same-size, same-type peers (139 models)
- Meet CEE 2025
- 87%
- 94 models
How LG compares with comparable models
- LG
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index139 models scored | 58% | 9th of 29 | — |
| COP at 5°F139 models scored | 56% | 17th of 29 | 1.96 |
| Capacity retention at 5°F139 models scored | 57% | 11th of 29 | 71% |
| HSPF2139 models scored | 54% | 13th of 29 | 9.1 |
| SEER2139 models scored | 52% | 17th of 29 | 20.0 |
| EER2139 models scored | 67% | 4th of 29 | 12.3 |
| Heating capacity at 5°F139 models scored | 63% | 7th of 29 | 15,350 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 87% | 94 |
| CEE 2026 Tier 1 (Split ASHP) | 85.2% | 92 |
| CEE Advanced Tier (Split ASHP) | 12% | 13 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 79.6% | 86 |
| DOE Cold Climate Heat Pump Challenge | 12% | 13 |
| ENERGY STAR Cold Climate | 59.3% | 64 |
Sizes and duct types offered
- LG (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 12 | 55% | 80% | 44% | 49% |
| Ducted, 2 tons | 9 | 53% | 71% | 54% | 46% |
| Ducted, 2.5 to 3 tons | 11 | 63% | 78% | 64% | 54% |
| Ducted, 3.5 to 4.5 tons | 16 | 67% | 66% | 72% | 67% |
| Ducted, 5 tons and up | 2 | 81% | 73% | 83% | 81% |
| Non-ducted, up to 1.5 tons | 51 | 51% | 37% | 47% | 48% |
| Non-ducted, 2 tons | 15 | 53% | 36% | 47% | 48% |
| Non-ducted, 2.5 to 3 tons | 12 | 64% | 70% | 53% | 58% |
| Non-ducted, 3.5 to 4.5 tons | 10 | 69% | 79% | 60% | 49% |
| Non-ducted, 5 tons and up | 1 | 86% | 58% | 73% | 99% |
Every LG model in the market
- LG models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
LG in the cold
- All listed models (median, middle 50% and 80%)
- LG (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| LG, 47°F | 55 | 100% | 100% | 100% | 100% | 100% |
| LG, 17°F | 55 | 65% | 73% | 79% | 87% | 92% |
| LG, 5°F | 55 | 58% | 61% | 73% | 80% | 87% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| LG, 47°F | 55 | 2.61 | 2.79 | 2.95 | 3.06 | 3.4 |
| LG, 17°F | 55 | 2.04 | 2.1 | 2.2 | 2.51 | 2.64 |
| LG, 5°F | 55 | 1.8 | 1.87 | 2.04 | 2.2 | 2.3 |
Source: NEEP ccASHP list · as of
Top LG models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1KUMXA421ALG · KUMXA421A | 3.5 tons42,000 Btu/h · Non-ducted | 100% | 2.29 | 11.0 | 48,000 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215402347 | Non-ducted, 3.5 to 4.5 tons | 95.9 |
| 2KUMXB601ALG · KUMXB601A | 5 tons60,000 Btu/h · Ducted | 82% | 2.33 | 9.5 | 52,500 | 18.5 | CEE 25CEE 26Xcel | 3 | 215402344 | Ducted, 5 tons and up | 94.7 |
| 3KUMXA361ALG · KUMXA361A | 3 tons36,000 Btu/h · Non-ducted | 100% | 2.27 | 11.0 | 45,000 | 22.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215402345 | Non-ducted, 2.5 to 3 tons | 93.7 |
| 4KUMXA481ALG · KUMXA481A | 4 tons48,000 Btu/h · Ducted | 100% | 2.33 | 10.0 | 52,500 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215408637 | Ducted, 3.5 to 4.5 tons | 90.4 |
| 5ZRUM036GSS0LG · ZRUM036GSS0 | 3 tons36,000 Btu/h · Non-ducted | 100% | 2.30 | 10.6 | 42,000 | 23.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 214914950 | Non-ducted, 2.5 to 3 tons | 90.1 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1KUSAL092ALG · KUSAL092Awith ductless indoor unit KNSAL092A | 1 ton9,000 Btu/h · Non-ducted | 109% | 2.05 | 13.5 | 27.0 | 15.8 | CEE 25CEE 26Xcel | 1 | 218861285 | Non-ducted, up to 1.5 tons | 92.0 | 87.7 | 96.3 | 87.7 |
| 2KUSAL091ALG · KUSAL091Awith ductless indoor unit KNSAL091A | 1 ton9,000 Btu/h · Non-ducted | 109% | 2.04 | 13.5 | 27.0 | 15.8 | CEE 25CEE 26XcelES CC | 1 | 216368959 | Non-ducted, up to 1.5 tons | 91.9 | 87.5 | 96.3 | 87.5 |
| 3KUMXA421ALG · KUMXA421A | 3.5 tons42,000 Btu/h · Ducted | 100% | 2.27 | 10.0 | 19.0 | 13.1 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215402348 | Ducted, 3.5 to 4.5 tons | 91.2 | 89.3 | 93.1 | 89.3 |
| 4KUSXA301ALG · KUSXA301Awith ductless indoor unit KNSCB301A | 2.5 tons30,000 Btu/h · Non-ducted | 100% | 2.10 | 10.4 | 25.0 | 15.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 96 | 214826535 | Non-ducted, 2.5 to 3 tons | 90.4 | 82.6 | 98.2 | 82.6 |
| 5KUMXA481ALG · KUMXA481A | 4 tons48,000 Btu/h · Ducted | 100% | 2.33 | 10.0 | 18.5 | 12.6 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215408637 | Ducted, 3.5 to 4.5 tons | 90.2 | 90.4 | 90.0 | 90.4 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | KUSXA301A | 3.43 | Ducted, 2 tons | 100% | 217198620 |
| Capacity retention at 5°F | KUSXA181A | 137% | Ducted, up to 1.5 tons | 100% | 217581954 |
| HSPF2 | KUSAL091A | 13.5 | Non-ducted, up to 1.5 tons | 97% | 216368959 |
| SEER2 | ZRUM060GSS0 | 23.0 | Non-ducted, 5 tons and up | 98% | 214914943 |
| EER2 | ZRUN024GSS0 | 14.8 | Ducted, 2 tons | 100% | 214914956 |
| Heating capacity at 5°F | KUSXA181A | 25,000 Btu/h | Ducted, up to 1.5 tons | 100% | 215588567 |
LG size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 84.0(50 is the typical model of its size class)KUSXA181Awith ducted air handler C/SDXW-19-**-EF-1A82+CF019SCUB+TXV+TDR10 of 10 models qualify · AHRI 218445518 | 81.0(50 is the typical model of its size class)KUSXA181Awith ducted air handler C/SDXW-19-**-EF-1A82+CF019SCUB+TXV+TDR10 of 10 models have all five ratings · AHRI 218445518 |
| Ducted, 2 tons | 83.4(50 is the typical model of its size class)KUSXA241Awith ducted air handler C/SDXW-25-**-EF-1A83+CF025SDUB+TXV+TDR9 of 9 models qualify · AHRI 218445517 | 79.6(50 is the typical model of its size class)ZRUN024GSS08 of 8 models have all five ratings · AHRI 214914956 |
| Ducted, 2.5 to 3 tons | 87.4(50 is the typical model of its size class)ZRUM036GSS011 of 11 models qualify · AHRI 214914952 | 89.4(50 is the typical model of its size class)KUMXA361A12 of 12 models have all five ratings · AHRI 215402346 |
| Ducted, 3.5 to 4.5 tons | 90.4(50 is the typical model of its size class)KUMXA481A18 of 18 models qualify · AHRI 215408637 | 91.2(50 is the typical model of its size class)KUMXA421A18 of 18 models have all five ratings · AHRI 215402348 |
| Ducted, 5 tons and up | 94.7(50 is the typical model of its size class)KUMXB601A2 of 2 models qualify · AHRI 215402344 | 89.4(50 is the typical model of its size class)KUMXB601A2 of 2 models have all five ratings · AHRI 215402344 |
| Non-ducted, up to 1.5 tons | 87.7(50 is the typical model of its size class)KUSAL092Awith ductless indoor unit KNSAL092A50 of 51 models qualify · AHRI 218861285 | 92.0(50 is the typical model of its size class)KUSAL092Awith ductless indoor unit KNSAL092A51 of 51 models have all five ratings · AHRI 218861285 |
| Non-ducted, 2 tons | 86.2(50 is the typical model of its size class)ZRUN024GSS09 of 15 models qualify · AHRI 215223214 | 78.6(50 is the typical model of its size class)ZRUN024GSS015 of 15 models have all five ratings · AHRI 214914954 |
| Non-ducted, 2.5 to 3 tons | 93.7(50 is the typical model of its size class)KUMXA361A12 of 12 models qualify · AHRI 215402345 | 90.4(50 is the typical model of its size class)KUSXA301Awith ductless indoor unit KNSCB301A12 of 12 models have all five ratings · AHRI 214826535 |
| Non-ducted, 3.5 to 4.5 tons | 95.9(50 is the typical model of its size class)KUMXA421A8 of 9 models qualify · AHRI 215402347 | 89.1(50 is the typical model of its size class)KUMXA421A9 of 9 models have all five ratings · AHRI 215402347 |
| Non-ducted, 5 tons and up | 85.4(50 is the typical model of its size class)KUMXB601A2 of 2 models qualify · AHRI 215408633 | 85.7(50 is the typical model of its size class)ZRUM060GSS02 of 2 models have all five ratings · AHRI 214914943 |
Newest LG certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| KUSXE601ALGwith ducted air handler BV**C5*60+TXV | 4 tons50,500 Btu/h · Ducted | 1.98 | 75% | 8.0 | 15.0 | CEE 25CEE 26Xcel | 66 | 218867465 |
| KUSXE481ALGwith ducted air handler LKMMA60D2 | 4 tons45,500 Btu/h · Ducted | 1.90 | 80% | 8.5 | 15.2 | CEE 25CEE 26Xcel | 83 | 218864228 |
| KUSXE241ALGwith ducted air handler LKMMA30B2 | 1.5 tons20,000 Btu/h · Ducted | 2.10 | 58% | 8.5 | 15.2 | CEE 25 | 126 | 218864227 |
| KUSXE421ALGwith indoor coil LKMMA48C2 and furnace LNAVE100C1 | 3.5 tons41,000 Btu/h · Ducted | 1.80 | 84% | 8.5 | 16.0 | None | 17 | 218864222 |
| KUSXE181ALGwith indoor coil LKMMA24B2 and furnace LNAVE080B1 | 1.5 tons17,000 Btu/h · Ducted | 2.10 | 67% | 8.5 | 15.2 | CEE 25CEE 26 | 35 | 218864216 |
Compare LG
LG includes these brand names as listed in AHRI: LG. Standards are checked against published thresholds; program rules beyond ratings are not checked.