Skip to content

LG vs Nortek Global HVAC heat pumps

Measured against models of the same size and duct type, LG scores higher on 6 of the 6 ratings. LG has 100 outdoor models, Nortek Global HVAC has 109 outdoor models.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
LG and Nortek Global HVAC on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, LG scores higher on 6 of the 6 ratings.
  • LG
  • Nortek Global HVAC
  • Other ranked manufacturers
LGNortek G…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingLGNortek Global HVAC
Efficiency index56% (higher)median — · 10th ranked31% (higher)median — · 29th ranked
COP at 5°F56% (higher)median 1.96 · 17th ranked23% (higher)median 1.75 · 29th ranked
Capacity retention at 5°F57% (higher)median 74% · 9th ranked28% (higher)median 49% · 29th ranked
HSPF251% (higher)median 9.0 · 14th ranked28% (higher)median 7.5 · 29th ranked
SEER249% (higher)median 20.0 · 17th ranked32% (higher)median 14.3 · 29th ranked
EER264% (higher)median 12.3 · 4th ranked42% (higher)median 11.0 · 22nd ranked
Heating capacity at 5°F61% (higher)median 15,550 Btu/h · 7th ranked28% (higher)median 16,200 Btu/h · 29th ranked
Outdoor models100109
AHRI certifications1,179781

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardLGNortek Global HVAC
CEE 2025 Tier 1 (Split ASHP)86%86 models28.4%31 models
CEE 2026 Tier 1 (Split ASHP)82%82 models24.8%27 models
CEE Advanced Tier (Split ASHP)11%11 models1.8%2 models
Xcel Energy Colorado cold-climate ASHP (2025)78%78 models20.2%22 models
DOE Cold Climate Heat Pump Challenge11%11 models1.8%2 models
ENERGY STAR Cold Climate64%64 models11%12 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 9 groups where both have models
  • LG
  • Nortek Global HVAC
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeLGNortek Global HVAC
Ducted, up to 1.5 tons12 · index 54%6 · index 25%
Ducted, 2 tons9 · index 53%15 · index 25%
Ducted, 2.5–3 tons11 · index 62%28 · index 25%
Ducted, 3.5–4.5 tons16 · index 66%38 · index 30%
Ducted, 5 tons and up2 · index 81%4 · index 18%
Non-ducted, up to 1.5 tons44 · index 46%12 · index 44%
Non-ducted, 2 tons14 · index 50%4 · index 50%
Non-ducted, 2.5–3 tons12 · index 63%6 · index 42%
Non-ducted, 3.5–4.5 tons10 · index 69%1 · index 68%
Non-ducted, 5 tons and up1 · index 85%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeLGCold-climate score, best modelNortek Global HVACCold-climate score, best model
Ducted, up to 1.5 tons80.4(50 is the typical model of its size class) (higher)KUSXA181Awith ducted air handler MSVT24***852FAA10 of 10 models qualify · AHRI 21758195439.3(50 is the typical model of its size class)DXH18FMK3IH1 of 6 models qualify · AHRI 215746315
Ducted, 2 tons78.1(50 is the typical model of its size class) (higher)ZRUN024GSS010 of 10 models qualify · AHRI 21491495649.0(50 is the typical model of its size class)DXH24FMK3IH1 of 14 models qualify · AHRI 215746317
Ducted, 2.5–3 tons87.4(50 is the typical model of its size class) (higher)ZRUM036GSS010 of 10 models qualify · AHRI 21491495276.9(50 is the typical model of its size class)UXH24-36MSK3IHwith ducted air handler UMD36MSK3IH3 of 29 models qualify · AHRI 217138207
Ducted, 3.5–4.5 tons90.4(50 is the typical model of its size class) (higher)KUMXA481A18 of 18 models qualify · AHRI 21540863785.1(50 is the typical model of its size class)UXH48-60MSK3IHwith ducted air handler UMD60MSK3IH2 of 38 models qualify · AHRI 217138209
Ducted, 5 tons and up94.6(50 is the typical model of its size class)KUMXB601A2 of 2 models qualify · AHRI 215402344None on this board (0 of 4 models qualify)
Non-ducted, up to 1.5 tons86.8(50 is the typical model of its size class) (higher)KUSAL091Awith ductless indoor unit KNSAL091A44 of 44 models qualify · AHRI 21636895966.8(50 is the typical model of its size class)WHS18SZB21Swith ductless indoor unit WHS18WMB21S10 of 12 models qualify · AHRI 217101981
Non-ducted, 2 tons85.4(50 is the typical model of its size class) (higher)ZRUN024GSS07 of 14 models qualify · AHRI 21522321467.5(50 is the typical model of its size class)DXH24FMK3IH4 of 4 models qualify · AHRI 215746311
Non-ducted, 2.5–3 tons93.7(50 is the typical model of its size class) (higher)KUMXA361A12 of 12 models qualify · AHRI 21540234577.2(50 is the typical model of its size class)DXH36FMK3IH5 of 6 models qualify · AHRI 215746313
Non-ducted, 3.5–4.5 tons95.9(50 is the typical model of its size class) (higher)KUMXA421A8 of 9 models qualify · AHRI 21540234766.5(50 is the typical model of its size class)DXH42FMK3IH1 of 1 models qualify · AHRI 215746314
Non-ducted, 5 tons and up84.7(50 is the typical model of its size class)KUMXB601A2 of 2 models qualify · AHRI 215408633No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeLGAll-around score, best modelNortek Global HVACAll-around score, best model
Ducted, up to 1.5 tons78.7(50 is the typical model of its size class) (higher)KUSXA181Awith ducted air handler MSVT24***852FAA10 of 10 models have all five ratings · AHRI 21758195448.6(50 is the typical model of its size class)DXH18FMK3IH6 of 6 models have all five ratings · AHRI 215746315
Ducted, 2 tons79.5(50 is the typical model of its size class) (higher)ZRUN024GSS08 of 8 models have all five ratings · AHRI 21491495672.4(50 is the typical model of its size class)UXH24-36MSK3IHwith ducted air handler UMD24MSK3IH15 of 15 models have all five ratings · AHRI 217138206
Ducted, 2.5–3 tons89.3(50 is the typical model of its size class) (higher)KUMXA361A12 of 12 models have all five ratings · AHRI 21540234661.6(50 is the typical model of its size class)DXH30FMK3IH25 of 28 models have all five ratings · AHRI 215746318
Ducted, 3.5–4.5 tons91.2(50 is the typical model of its size class) (higher)KUMXA421A18 of 18 models have all five ratings · AHRI 21540234883.1(50 is the typical model of its size class)UXH48-60MSK3IHwith ducted air handler UMD48MSK3IH35 of 38 models have all five ratings · AHRI 217138208
Ducted, 5 tons and up89.5(50 is the typical model of its size class) (higher)KUMXB601A2 of 2 models have all five ratings · AHRI 21540234417.9(50 is the typical model of its size class)RHPXYB060AJT1 of 4 models have all five ratings · AHRI 217469149
Non-ducted, up to 1.5 tons91.4(50 is the typical model of its size class) (higher)KUSAL091Awith ductless indoor unit KNSAL091A44 of 44 models have all five ratings · AHRI 21636895978.0(50 is the typical model of its size class)DXH09PSK3IHwith ductless indoor unit DHH09PUK3IH12 of 12 models have all five ratings · AHRI 216011767
Non-ducted, 2 tons77.2(50 is the typical model of its size class) (higher)ZRUN024GSS014 of 14 models have all five ratings · AHRI 21491495472.2(50 is the typical model of its size class)DXH24PSK3IHwith ductless indoor unit DHH24PUK3IH4 of 4 models have all five ratings · AHRI 216011771
Non-ducted, 2.5–3 tons90.3(50 is the typical model of its size class) (higher)KUSXA301Awith ductless indoor unit KNSCB301A12 of 12 models have all five ratings · AHRI 21482653570.5(50 is the typical model of its size class)DXH30FMK3IH6 of 6 models have all five ratings · AHRI 215746312
Non-ducted, 3.5–4.5 tons89.3(50 is the typical model of its size class) (higher)KUMXA421A9 of 9 models have all five ratings · AHRI 21540234767.7(50 is the typical model of its size class)DXH42FMK3IH1 of 1 models have all five ratings · AHRI 215746314
Non-ducted, 5 tons and up85.4(50 is the typical model of its size class)ZRUM060GSS02 of 2 models have all five ratings · AHRI 214914943No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingLGNortek Global HVAC
COP at 5°Fbeats 100% · 3.17KUSXB181ADucted, up to 1.5 tonsbeats 100% · 2.53WHS18SZB21SNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 100% · 137%KUSXA181ADucted, up to 1.5 tonsbeats 99% · 114%UXH48-60MSK3IHDucted, 3.5–4.5 tons
HSPF2beats 97% · 13.5KUSAL091ANon-ducted, up to 1.5 tonsbeats 90% · 10.5UXH48-60MSK3IHDucted, 3.5–4.5 tons
SEER2beats 98% · 23.0ZRUM060GSS0Non-ducted, 5 tons and upbeats 97% · 26.0DXH24PSK3IHNon-ducted, 2 tons
EER2beats 100% · 14.8ZRUN024GSS0Ducted, 2 tonsbeats 94% · 13.0DXH42FMK3IHNon-ducted, 3.5–4.5 tons
Heating capacity at 5°Fbeats 100% · 25,000 Btu/hKUSXA181ADucted, up to 1.5 tonsbeats 98% · 54,000 Btu/hUXH48-60MSK3IHDucted, 3.5–4.5 tons

More comparisons