Nortek Global HVAC heat pump efficiency: 109 outdoor models compared
Nortek Global HVAC has 109 heat pump outdoor models certified with this refrigerant group, in 785 AHRI-certified combinations. They are also sold as FRIGIDAIRE, GIBSON, Intertherm, MAYTAG, MILLER, NORDYNE, NORTEK GLOBAL HVAC LLC, WESTINGHOUSE. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Nortek Global HVAC makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 109
- AHRI certifications
- 785
- Efficiency index
- 32%
- Typical model vs same-size, same-type peers (111 models)
- Meet CEE 2025
- 28.4%
- 31 models
How Nortek Global HVAC compares with comparable models
- Nortek Global HVAC
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index111 models scored | 32% | 29th of 29 | — |
| COP at 5°F111 models scored | 24% | 29th of 29 | 1.75 |
| Capacity retention at 5°F111 models scored | 28% | 29th of 29 | 49% |
| HSPF2114 models scored | 28% | 29th of 29 | 7.5 |
| SEER2114 models scored | 32% | 29th of 29 | 14.3 |
| EER2114 models scored | 42% | 22nd of 29 | 11.0 |
| Heating capacity at 5°F111 models scored | 28% | 29th of 29 | 16,600 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 28.4% | 31 |
| CEE 2026 Tier 1 (Split ASHP) | 24.8% | 27 |
| CEE Advanced Tier (Split ASHP) | 1.8% | 2 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 20.2% | 22 |
| DOE Cold Climate Heat Pump Challenge | 1.8% | 2 |
| ENERGY STAR Cold Climate | 11% | 12 |
Sizes and duct types offered
- Nortek Global HVAC (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 6 | 25% | 30% | 17% | 28% |
| Ducted, 2 tons | 15 | 25% | 15% | 25% | 22% |
| Ducted, 2.5 to 3 tons | 29 | 26% | 15% | 26% | 27% |
| Ducted, 3.5 to 4.5 tons | 37 | 30% | 20% | 28% | 28% |
| Ducted, 5 tons and up | 4 | 35% | 18% | 33% | 50% |
| Non-ducted, up to 1.5 tons | 12 | 46% | 50% | 33% | 49% |
| Non-ducted, 2 tons | 4 | 51% | 26% | 46% | 52% |
| Non-ducted, 2.5 to 3 tons | 6 | 43% | 44% | 27% | 43% |
| Non-ducted, 3.5 to 4.5 tons | 1 | 68% | 82% | 40% | 43% |
Every Nortek Global HVAC model in the market
- Nortek Global HVAC models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Nortek Global HVAC in the cold
- All listed models (median, middle 50% and 80%)
- Nortek Global HVAC (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Nortek Global HVAC, 47°F | 23 | 100% | 100% | 100% | 100% | 100% |
| Nortek Global HVAC, 17°F | 23 | 69% | 76% | 84% | 87% | 96% |
| Nortek Global HVAC, 5°F | 23 | 56% | 59% | 70% | 76% | 88% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Nortek Global HVAC, 47°F | 23 | 2.88 | 3.15 | 3.23 | 3.33 | 3.53 |
| Nortek Global HVAC, 17°F | 23 | 2.01 | 2.09 | 2.25 | 2.39 | 2.61 |
| Nortek Global HVAC, 5°F | 23 | 1.8 | 1.82 | 1.94 | 2.04 | 2.1 |
Source: NEEP ccASHP list · as of
Top Nortek Global HVAC models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1UXH48-60MSK3IHGibson · E Serieswith ducted air handler UMD60MSK3IH | 4.5 tons53,000 Btu/h · Ducted | 100% | 2.10 | 10.0 | 54,000 | 18.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 14 | 217138209 | Ducted, 3.5 to 4.5 tons | 83.9 |
| 2DXH36FMK3IHGIBSON · Multizone Outdoors | 3 tons36,000 Btu/h · Non-ducted | 100% | 2.10 | 10.0 | 36,000 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 6 | 215746313 | Non-ducted, 2.5 to 3 tons | 77.8 |
| 3UXH24-36MSK3IHGibson · E Serieswith ducted air handler UMD36MSK3IH | 3 tons34,000 Btu/h · Ducted | 100% | 2.00 | 10.0 | 34,000 | 18.2 | CEE 25CEE 26XcelES CC | 14 | 217138207 | Ducted, 2 tons | 77.3 |
| 4DXH30FMK3IHGIBSON · Multizone Outdoors | 2.5 tons28,400 Btu/h · Non-ducted | 90% | 2.07 | 10.0 | 27,000 | 21.0 | CEE 25CEE 26XcelES CC | 6 | 215746312 | Non-ducted, 2.5 to 3 tons | 70.5 |
| 5WHS18SZB21SWESTINGHOUSE · S**SZB2with ductless indoor unit WHS18WMB21S | 1.5 tons18,000 Btu/h · Non-ducted | 74% | 2.53 | 9.8 | 13,400 | 20.0 | CEE 25CEE 26Xcel | 1 | 217101981 | Non-ducted, up to 1.5 tons | 68.6 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1UXH48-60MSK3IHGibson · E Serieswith ducted air handler UMD48MSK3IH | 4 tons48,000 Btu/h · Ducted | 100% | 2.00 | 10.0 | 19.0 | 11.7 | CEE 25CEE 26CEE AdvXcelDOEES CC | 14 | 217138208 | Ducted, 3.5 to 4.5 tons | 80.0 | 78.9 | 81.2 | 83.9 |
| 2DXH09PSK3IHGIBSON · (24-26 SEER2) Minisplitswith ductless indoor unit DHH09PUK3IH | 1 ton9,100 Btu/h · Non-ducted | 90% | 1.88 | 10.4 | 26.0 | 15.0 | CEE 25CEE 26XcelES CC | 4 | 216011767 | Non-ducted, up to 1.5 tons | 79.1 | 63.8 | 94.4 | 63.8 |
| 3DXH24PSK3IHGIBSON · (24-26 SEER2) Minisplitswith ductless indoor unit DHH24PUK3IH | 2 tons22,000 Btu/h · Non-ducted | 79% | 1.80 | 10.0 | 26.0 | 13.7 | CEE 25CEE 26XcelES CC | 4 | 216011771 | Non-ducted, 2 tons | 73.1 | 51.7 | 94.5 | 51.7 |
| 4DXH30FMK3IHGIBSON · Multizone Outdoors | 2.5 tons28,400 Btu/h · Non-ducted | 90% | 2.07 | 10.0 | 21.0 | 13.6 | CEE 25CEE 26XcelES CC | 6 | 215746312 | Non-ducted, 2.5 to 3 tons | 71.2 | 70.5 | 72.0 | 70.5 |
| 5DXH12PSK3IHGIBSON · (24-26 SEER2) Minisplitswith ductless indoor unit DHH12PUK3IH | 1 ton12,000 Btu/h · Non-ducted | 92% | 1.95 | 9.5 | 24.5 | 13.0 | CEE 25CEE 26XcelES CC | 4 | 216011769 | Non-ducted, up to 1.5 tons | 69.5 | 59.5 | 79.6 | 59.5 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | WHS18SZB21S | 2.53 | Non-ducted, up to 1.5 tons | 100% | 217101981 |
| Capacity retention at 5°F | UXH48-60MSK3IH | 114% | Ducted, 3.5 to 4.5 tons | 99% | 217754375 |
| HSPF2 | UXH48-60MSK3IH | 10.0 | Ducted, 3.5 to 4.5 tons | 87% | 217138208 |
| SEER2 | DXH24PSK3IH | 26.0 | Non-ducted, 2 tons | 97% | 216011771 |
| EER2 | DXH42FMK3IH | 13.0 | Non-ducted, 3.5 to 4.5 tons | 95% | 215746314 |
| Heating capacity at 5°F | UXH48-60MSK3IH | 54,000 Btu/h | Ducted, 3.5 to 4.5 tons | 98% | 217138209 |
Nortek Global HVAC size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 40.5(50 is the typical model of its size class)DXH18FMK3IH1 of 6 models qualify · AHRI 215746315 | 41.2(50 is the typical model of its size class)DXH18FMK3IH6 of 6 models have all five ratings · AHRI 215746315 |
| Ducted, 2 tons | 48.9(50 is the typical model of its size class)DXH24FMK3IH1 of 14 models qualify · AHRI 215746317 | 55.0(50 is the typical model of its size class)DXH24FMK3IH14 of 14 models have all five ratings · AHRI 215746317 |
| Ducted, 2.5 to 3 tons | 77.3(50 is the typical model of its size class)UXH24-36MSK3IHwith ducted air handler UMD36MSK3IH4 of 30 models qualify · AHRI 217138207 | 68.5(50 is the typical model of its size class)UXH24-36MSK3IHwith ducted air handler UMD36MSK3IH29 of 30 models have all five ratings · AHRI 217138207 |
| Ducted, 3.5 to 4.5 tons | 83.9(50 is the typical model of its size class)UXH48-60MSK3IHwith ducted air handler UMD60MSK3IH1 of 37 models qualify · AHRI 217138209 | 80.0(50 is the typical model of its size class)UXH48-60MSK3IHwith ducted air handler UMD48MSK3IH36 of 37 models have all five ratings · AHRI 217138208 |
| Ducted, 5 tons and up | None on this board (0 of 4 models qualify) | 44.2(50 is the typical model of its size class)RHPCYC060ACAlso listed as RHPCYC060AD3 of 4 models have all five ratings · AHRI 218426050 |
| Non-ducted, up to 1.5 tons | 68.6(50 is the typical model of its size class)WHS18SZB21Swith ductless indoor unit WHS18WMB21S10 of 12 models qualify · AHRI 217101981 | 79.1(50 is the typical model of its size class)DXH09PSK3IHwith ductless indoor unit DHH09PUK3IH12 of 12 models have all five ratings · AHRI 216011767 |
| Non-ducted, 2 tons | 68.5(50 is the typical model of its size class)DXH24FMK3IH4 of 4 models qualify · AHRI 215746311 | 73.1(50 is the typical model of its size class)DXH24PSK3IHwith ductless indoor unit DHH24PUK3IH4 of 4 models have all five ratings · AHRI 216011771 |
| Non-ducted, 2.5 to 3 tons | 77.8(50 is the typical model of its size class)DXH36FMK3IH5 of 6 models qualify · AHRI 215746313 | 71.2(50 is the typical model of its size class)DXH30FMK3IH6 of 6 models have all five ratings · AHRI 215746312 |
| Non-ducted, 3.5 to 4.5 tons | 67.0(50 is the typical model of its size class)DXH42FMK3IH1 of 1 models qualify · AHRI 215746314 | 67.8(50 is the typical model of its size class)DXH42FMK3IH1 of 1 models have all five ratings · AHRI 215746314 |
Newest Nortek Global HVAC certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| PSH4BE5M1SP30KMAYTAGwith ducted air handler V2430B-*EC*B**1 | 2 tons22,600 Btu/h · Ducted | 1.40 | 54% | 6.1 | 12.0 | None | 16 | 218441290 |
| CSH4BE5M1SP30KMAYTAGwith ducted air handler V2430B-*EC*B**1 | 2 tons22,600 Btu/h · Ducted | 1.40 | 54% | 6.1 | 12.0 | None | 16 | 218441288 |
| WSH4BE5M1SP30KGIBSONwith ducted air handler V2430B-*EC*B**1 | 2 tons22,600 Btu/h · Ducted | 1.40 | 54% | 6.1 | 12.0 | None | 45 | 218440865 |
| FSH4BE5M1SP30KGIBSONwith ducted air handler V2430B-*EC*B**1 | 2 tons22,600 Btu/h · Ducted | 1.40 | 54% | 6.1 | 12.0 | None | 32 | 218440863 |
| RHPCYC060AJFRIGIDAIRE | 5 tons57,000 Btu/h · Ducted | — | — | 7.2 | 16.1 | None | 1 | 218426075 |
Compare Nortek Global HVAC
Nortek Global HVAC includes these brand names as listed in AHRI: FRIGIDAIRE, GIBSON, Intertherm, MAYTAG, MILLER, NORDYNE, NORTEK GLOBAL HVAC LLC, WESTINGHOUSE. Standards are checked against published thresholds; program rules beyond ratings are not checked.