REVOLV heat pump efficiency: 11 outdoor models compared
REVOLV has 11 heat pump outdoor models certified with this refrigerant group, in 24 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes REVOLV makes. REVOLV has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 11
- AHRI certifications
- 24
- Efficiency index
- 17%
- Typical model vs same-size, same-type peers (11 models)
- Meet CEE 2025
- 0%
- 0 models
How REVOLV compares with comparable models
- REVOLV
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index11 models scored | 17% | Not ranked | — |
| COP at 5°F11 models scored | 7% | Not ranked | 1.50 |
| Capacity retention at 5°F11 models scored | 13% | Not ranked | 49% |
| HSPF211 models scored | 17% | Not ranked | 6.7 |
| SEER211 models scored | 13% | Not ranked | 13.4 |
| EER211 models scored | 32% | Not ranked | 10.6 |
| Heating capacity at 5°F11 models scored | 13% | Not ranked | 16,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0% | 0 |
| CEE 2026 Tier 1 (Split ASHP) | 0% | 0 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- REVOLV (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, 2 tons | 2 | 13% | 8% | 13% | 10% |
| Ducted, 2.5–3 tons | 4 | 17% | 7% | 18% | 14% |
| Ducted, 3.5–4.5 tons | 5 | 20% | 7% | 17% | 14% |
Every REVOLV model in the market
- REVOLV models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 865 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 726 | 1.80 | 1.86 | 2.00 | 2.12 | 2.41 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top REVOLV models
Cold-climate picks
No REVOLV model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1HSH4ME5M1SP42KREVOLVwith ducted air handler C85DAMX43U*B | 3.5 tons40,500 Btu/h · Ducted | 51% | 1.75 | 7.5 | 14.3 | 11.0 | None | 3 | 217179931 | Ducted, 3.5–4.5 tons | 27.9 | 22.0 | 33.8 | Not a pick |
| 2HSH4ME5M1SP48KREVOLVwith indoor coil C85DAMX4960U-B and furnace E7E*-0**H | 4 tons46,000 Btu/h · Ducted | 49% | 1.75 | 7.5 | 14.3 | 11.0 | None | 4 | 216955284 | Ducted, 3.5–4.5 tons | 27.5 | 21.1 | 33.8 | Not a pick |
| 3HSH4ME5M1SP36KREVOLVwith indoor coil C75B(A,H)MX36C*B and furnace MG3P-054U1AAB | 3 tons34,600 Btu/h · Ducted | 52% | 1.75 | 7.5 | 14.3 | 11.0 | None | 4 | 217476456 | Ducted, 2.5–3 tons | 24.7 | 22.3 | 27.1 | Not a pick |
| 4HSH4ME5M1SP30KREVOLVwith ducted air handler C85DAMX3036U*B | 2.5 tons29,600 Btu/h · Ducted | 52% | 1.75 | 7.5 | 14.3 | 11.0 | None | 4 | 217179929 | Ducted, 2.5–3 tons | 24.6 | 22.0 | 27.1 | Not a pick |
| 5HSH4ME5M1SP24KREVOLVwith indoor coil C75B(A,H)MX24C*B and furnace MG3P-054U1AAB | 2 tons23,400 Btu/h · Ducted | 51% | 1.75 | 7.5 | 14.3 | 11.0 | None | 3 | 217448218 | Ducted, 2 tons | 19.1 | 17.4 | 20.8 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | HSH4ME5M1SP30K | 1.75 | Ducted, 2.5–3 tons | 14% | 217179929 |
| Capacity retention at 5°F | HSH4ME5M1SP36K | 52% | Ducted, 2.5–3 tons | 21% | 217476456 |
| HSPF2 | HSH4ME5M1SP48K | 7.5 | Ducted, 3.5–4.5 tons | 27% | 216955284 |
| SEER2 | HSH4ME5M1SP48K | 14.3 | Ducted, 3.5–4.5 tons | 22% | 216955284 |
| EER2 | HSH4ME5M1SP48K | 11.0 | Ducted, 3.5–4.5 tons | 40% | 216955284 |
| Heating capacity at 5°F | HSH4ME5M1SP36K | 17,800 Btu/h | Ducted, 2.5–3 tons | 23% | 217179930 |
REVOLV size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, 2 tons | None on this board (0 of 2 models qualify) | 19.1(50 is the typical model of its size class)HSH4ME5M1SP24Kwith indoor coil C75B(A,H)MX24C*B and furnace MG3P-054U1AAB2 of 2 models have all five ratings · AHRI 217448218 |
| Ducted, 2.5–3 tons | None on this board (0 of 4 models qualify) | 24.7(50 is the typical model of its size class)HSH4ME5M1SP36Kwith indoor coil C75B(A,H)MX36C*B and furnace MG3P-054U1AAB4 of 4 models have all five ratings · AHRI 217476456 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 5 models qualify) | 27.9(50 is the typical model of its size class)HSH4ME5M1SP42Kwith ducted air handler C85DAMX43U*B5 of 5 models have all five ratings · AHRI 217179931 |
Newest REVOLV certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| HSH4ME5M1SP48KREVOLVwith ducted air handler B65EMMX48K-C | 4 tons46,000 Btu/h · Ducted | 1.75 | 49% | 7.5 | 14.3 | None | 4 | 217746932 |
| HSH4ME5M1SP42KREVOLVwith ducted air handler B65EMMX48K-C | 3.5 tons40,500 Btu/h · Ducted | 1.75 | 50% | 7.5 | 14.3 | None | 3 | 217746931 |
| HSH4ME5M1SP36KREVOLVwith ducted air handler B65BMMX42K-C | 3 tons34,600 Btu/h · Ducted | 1.75 | 50% | 7.5 | 14.3 | None | 4 | 217746930 |
| HSH4ME5M1SP30KREVOLVwith ducted air handler B65BMMX30K-B | 2.5 tons28,600 Btu/h · Ducted | 1.75 | 50% | 7.5 | 14.3 | None | 4 | 217746929 |
| HSH4ME5M1SP24KREVOLVwith ducted air handler B65BMMX24K-A | 2 tons23,400 Btu/h · Ducted | 1.75 | 50% | 7.5 | 14.3 | None | 3 | 217746928 |
Compare REVOLV