Both views use the same certified data. This device remembers your choice.
Nortek Global HVAC vs RUSSELL heat pumps
Measured against models of the same size and duct type, Nortek Global HVAC scores higher on 5 of the 6 ratings. Nortek Global HVAC has 109 outdoor models, RUSSELL has 111 outdoor models. RUSSELL has no QMID on file and is not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Nortek Global HVAC
- RUSSELL
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Nortek Global HVAC | RUSSELL |
|---|---|---|
| Efficiency index | 32%median — · 29th ranked | 33%median — |
| COP at 5°F | 24%median 1.75 · 29th ranked | 36%median 1.82 |
| Capacity retention at 5°F | 28% (higher)median 49% · 29th ranked | 21% (higher)median 45% |
| HSPF2 | 28% (higher)median 7.5 · 29th ranked | 24% (higher)median 7.2 |
| SEER2 | 32% (higher)median 14.3 · 29th ranked | 28% (higher)median 14.3 |
| EER2 | 42% (higher)median 11.0 · 22nd ranked | 36% (higher)median 10.6 |
| Heating capacity at 5°F | 28% (higher)median 16,600 Btu/h · 29th ranked | 21% (higher)median 18,000 Btu/h |
| Outdoor models | 109 | 111 |
| AHRI certifications | 785 | 2,009 |
Share of models meeting each standard
| Standard | Nortek Global HVAC | RUSSELL |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 28.4%31 models | 10.8%12 models |
| CEE 2026 Tier 1 (Split ASHP) | 24.8%27 models | 9%10 models |
| CEE Advanced Tier (Split ASHP) | 1.8%2 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 20.2%22 models | 7.2%8 models |
| DOE Cold Climate Heat Pump Challenge | 1.8%2 models | 0%0 models |
| ENERGY STAR Cold Climate | 11%12 models | 11.7%13 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Nortek Global HVAC
- RUSSELL
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Nortek Global HVAC | RUSSELL |
|---|---|---|
| Ducted, up to 1.5 tons | 6 · index 25% | 2 · index 28% |
| Ducted, 2 tons | 15 · index 25% | 12 · index 29% |
| Ducted, 2.5 to 3 tons | 29 · index 26% | 33 · index 30% |
| Ducted, 3.5 to 4.5 tons | 37 · index 30% | 44 · index 36% |
| Ducted, 5 tons and up | 4 · index 35% | 20 · index 35% |
| Non-ducted, up to 1.5 tons | 12 · index 46% | None |
| Non-ducted, 2 tons | 4 · index 51% | None |
| Non-ducted, 2.5 to 3 tons | 6 · index 43% | None |
| Non-ducted, 3.5 to 4.5 tons | 1 · index 68% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | Nortek Global HVACCold-climate score, best model | RUSSELLCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 40.5(50 is the typical model of its size class)DXH18FMK3IH1 of 6 models qualify · AHRI 215746315 | None on this board (0 of 2 models qualify) |
| Ducted, 2 tons | 48.9(50 is the typical model of its size class)DXH24FMK3IH1 of 14 models qualify · AHRI 215746317 | 70.4(50 is the typical model of its size class) (higher)RD18AY24AJVCwith indoor coil TCFY2417STANM and furnace S962V0603A17M42 of 12 models qualify · AHRI 217906632 |
| Ducted, 2.5 to 3 tons | 77.3(50 is the typical model of its size class)UXH24-36MSK3IHwith ducted air handler UMD36MSK3IH4 of 30 models qualify · AHRI 217138207 | 78.4(50 is the typical model of its size class) (higher)RD18AY36AJVCwith indoor coil TCFY3621MTANM and furnace S801V0504A17UHS2 of 33 models qualify · AHRI 216892076 |
| Ducted, 3.5 to 4.5 tons | 83.9(50 is the typical model of its size class) (higher)UXH48-60MSK3IHwith ducted air handler UMD60MSK3IH1 of 37 models qualify · AHRI 217138209 | 80.8(50 is the typical model of its size class)SP19AY48AJVCwith ducted air handler SHMVY4821SEACA4 of 44 models qualify · AHRI 215576404 |
| Ducted, 5 tons and up | None on this board (0 of 4 models qualify) | None on this board (0 of 20 models qualify) |
| Non-ducted, up to 1.5 tons | 68.6(50 is the typical model of its size class)WHS18SZB21Swith ductless indoor unit WHS18WMB21S10 of 12 models qualify · AHRI 217101981 | No models in this size class |
| Non-ducted, 2 tons | 68.5(50 is the typical model of its size class)DXH24FMK3IH4 of 4 models qualify · AHRI 215746311 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 77.8(50 is the typical model of its size class)DXH36FMK3IH5 of 6 models qualify · AHRI 215746313 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 67.0(50 is the typical model of its size class)DXH42FMK3IH1 of 1 models qualify · AHRI 215746314 | No models in this size class |
All-around best
| Size and duct type | Nortek Global HVACAll-around score, best model | RUSSELLAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 41.2(50 is the typical model of its size class) (higher)DXH18FMK3IH6 of 6 models have all five ratings · AHRI 215746315 | 39.2(50 is the typical model of its size class)SP15AY18AJ2Nwith ducted air handler RF2TY2421STANS2 of 2 models have all five ratings · AHRI 216533447 |
| Ducted, 2 tons | 55.0(50 is the typical model of its size class)DXH24FMK3IH14 of 14 models have all five ratings · AHRI 215746317 | 75.5(50 is the typical model of its size class) (higher)SP19AY24AJVCwith ducted air handler SHMVY3621MEACA12 of 12 models have all five ratings · AHRI 215739591 |
| Ducted, 2.5 to 3 tons | 68.5(50 is the typical model of its size class)UXH24-36MSK3IHwith ducted air handler UMD36MSK3IH29 of 30 models have all five ratings · AHRI 217138207 | 84.9(50 is the typical model of its size class) (higher)SP19AY36AJVCwith ducted air handler SHMVY3621MEACA22 of 33 models have all five ratings · AHRI 215576403 |
| Ducted, 3.5 to 4.5 tons | 80.0(50 is the typical model of its size class)UXH48-60MSK3IHwith ducted air handler UMD48MSK3IH36 of 37 models have all five ratings · AHRI 217138208 | 84.3(50 is the typical model of its size class) (higher)SP19AY48AJVCwith ducted air handler SHMVY4821SEACA26 of 43 models have all five ratings · AHRI 215576404 |
| Ducted, 5 tons and up | 44.2(50 is the typical model of its size class)RHPCYC060ACAlso listed as RHPCYC060AD3 of 4 models have all five ratings · AHRI 218426050 | 57.0(50 is the typical model of its size class) (higher)SP15AY60AJ2Nwith ducted air handler SH2CY6024STANN13 of 21 models have all five ratings · AHRI 215415481 |
| Non-ducted, up to 1.5 tons | 79.1(50 is the typical model of its size class)DXH09PSK3IHwith ductless indoor unit DHH09PUK3IH12 of 12 models have all five ratings · AHRI 216011767 | No models in this size class |
| Non-ducted, 2 tons | 73.1(50 is the typical model of its size class)DXH24PSK3IHwith ductless indoor unit DHH24PUK3IH4 of 4 models have all five ratings · AHRI 216011771 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 71.2(50 is the typical model of its size class)DXH30FMK3IH6 of 6 models have all five ratings · AHRI 215746312 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 67.8(50 is the typical model of its size class)DXH42FMK3IH1 of 1 models have all five ratings · AHRI 215746314 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Nortek Global HVAC | RUSSELL |
|---|---|---|
| COP at 5°F | beats 100% · 2.53WHS18SZB21SNon-ducted, up to 1.5 tons | beats 91% · 2.40RD16AY36AJVCDucted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 99% · 114%UXH48-60MSK3IHDucted, 3.5 to 4.5 tons | beats 88% · 97%SP19AY60AJVCDucted, 3.5 to 4.5 tons |
| HSPF2 | beats 87% · 10.0UXH48-60MSK3IHDucted, 3.5 to 4.5 tons | beats 87% · 10.0SP19AY48AJVCDucted, 3.5 to 4.5 tons |
| SEER2 | beats 97% · 26.0DXH24PSK3IHNon-ducted, 2 tons | beats 98% · 21.0SP19AY36AJVCDucted, 2.5 to 3 tons |
| EER2 | beats 95% · 13.0DXH42FMK3IHNon-ducted, 3.5 to 4.5 tons | beats 96% · 13.0RD18AY36AJVCDucted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 98% · 54,000 Btu/hUXH48-60MSK3IHDucted, 3.5 to 4.5 tons | beats 95% · 53,000 Btu/hSP19AY60AJVCDucted, 3.5 to 4.5 tons |