- Insights
- Manufacturers
- AireForce
Both views use the same certified data. This device remembers your choice.
AireForce heat pump efficiency: 70 outdoor models compared
AireForce has 70 heat pump outdoor models certified with this refrigerant group, in 210 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes AireForce makes. AireForce has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 70
- AHRI certifications
- 210
- Efficiency index
- 40%
- Typical model vs same-size, same-type peers (75 models)
- Meet CEE 2025
- 50%
- 35 models
How AireForce compares with comparable models
- AireForce
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index75 models scored | 40% | Not ranked | — |
| COP at 5°F75 models scored | 32% | Not ranked | 1.80 |
| Capacity retention at 5°F75 models scored | 41% | Not ranked | 70% |
| HSPF275 models scored | 39% | Not ranked | 8.6 |
| SEER275 models scored | 42% | Not ranked | 18.0 |
| EER275 models scored | 42% | Not ranked | 11.0 |
| Heating capacity at 5°F75 models scored | 42% | Not ranked | 16,200 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 50% | 35 |
| CEE 2026 Tier 1 (Split ASHP) | 48.6% | 34 |
| CEE Advanced Tier (Split ASHP) | 2.9% | 2 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 48.6% | 34 |
| DOE Cold Climate Heat Pump Challenge | 2.9% | 2 |
| ENERGY STAR Cold Climate | 17.1% | 12 |
Sizes and duct types offered
- AireForce (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 4 | 33% | 41% | 22% | 39% |
| Ducted, 2 tons | 7 | 34% | 22% | 35% | 32% |
| Ducted, 2.5 to 3 tons | 12 | 33% | 21% | 35% | 39% |
| Ducted, 3.5 to 4.5 tons | 14 | 34% | 28% | 37% | 32% |
| Non-ducted, up to 1.5 tons | 19 | 41% | 36% | 41% | 43% |
| Non-ducted, 2 tons | 6 | 48% | 25% | 54% | 50% |
| Non-ducted, 2.5 to 3 tons | 11 | 49% | 42% | 46% | 54% |
| Non-ducted, 3.5 to 4.5 tons | 2 | 59% | 60% | 40% | 70% |
Every AireForce model in the market
- AireForce models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
AireForce in the cold
- All listed models (median, middle 50% and 80%)
- AireForce (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| AireForce, 47°F | 34 | 100% | 100% | 100% | 100% | 100% |
| AireForce, 17°F | 34 | 68% | 72% | 78% | 85% | 91% |
| AireForce, 5°F | 34 | 58% | 64% | 70% | 73% | 84% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| AireForce, 47°F | 34 | 2.88 | 3.17 | 3.3 | 3.48 | 3.59 |
| AireForce, 17°F | 34 | 2 | 2.1 | 2.2 | 2.35 | 2.4 |
| AireForce, 5°F | 34 | 1.8 | 1.89 | 2 | 2 | 2.09 |
Source: NEEP ccASHP list · as of
Top AireForce models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1UXH48-60MSK3IHAireForce · E Serieswith ducted air handler UMD60MSK3IH | 4.5 tons53,000 Btu/h · Ducted | 100% | 2.10 | 10.0 | 54,000 | 18.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 217138201 | Ducted, 3.5 to 4.5 tons | 83.9 |
| 2DXH36FMK3IHAireForce · Multizone Outdoors | 3 tons36,000 Btu/h · Non-ducted | 100% | 2.10 | 10.0 | 36,000 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215746283 | Non-ducted, 2.5 to 3 tons | 77.8 |
| 3UXH24-36MSK3IHAireForce · E Serieswith ducted air handler UMD36MSK3IH | 3 tons34,000 Btu/h · Ducted | 100% | 2.00 | 10.0 | 34,000 | 18.2 | CEE 25CEE 26XcelES CC | 4 | 217138199 | Ducted, 2 tons | 77.3 |
| 4AC-48-HP-E-32AireForce · Mini-spilt Ducted serieswith ducted air handler AC-48-AH-E-32 | 4 tons48,000 Btu/h · Ducted | 84% | 2.10 | 9.0 | 40,500 | 16.0 | None | 1 | 218729454 | Ducted, 3.5 to 4.5 tons | 72.3 |
| 5DXH30FMK3IHAireForce · Multizone Outdoors | 2.5 tons28,400 Btu/h · Non-ducted | 90% | 2.07 | 10.0 | 27,000 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 215746282 | Non-ducted, 2.5 to 3 tons | 70.5 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1UXH48-60MSK3IHAireForce · E Serieswith ducted air handler UMD48MSK3IH | 4 tons48,000 Btu/h · Ducted | 100% | 2.00 | 10.0 | 19.0 | 11.7 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 217138200 | Ducted, 3.5 to 4.5 tons | 80.0 | 78.9 | 81.2 | 83.9 |
| 2DXH09PSK3IHAireForce · (24-26 SEER2) Minisplitswith ductless indoor unit DHH09PUK3IH | 1 ton9,100 Btu/h · Non-ducted | 90% | 1.88 | 10.4 | 26.0 | 15.0 | CEE 25CEE 26XcelES CC | 2 | 216011727 | Non-ducted, up to 1.5 tons | 79.1 | 63.8 | 94.4 | 63.8 |
| 3AC-24Z-E-M3AireForce · Multi-spilt series | 2 tons24,000 Btu/h · Non-ducted | 90% | 2.00 | 10.0 | 23.0 | 12.5 | CEE 25CEE 26Xcel | 1 | 218729435 | Non-ducted, 2 tons | 73.3 | 68.5 | 78.2 | 68.5 |
| 4DXH24PSK3IHAireForce · (24-26 SEER2) Minisplitswith ductless indoor unit DHH24PUK3IH | 2 tons22,000 Btu/h · Non-ducted | 79% | 1.80 | 10.0 | 26.0 | 13.7 | CEE 25CEE 26XcelES CC | 2 | 216011731 | Non-ducted, 2 tons | 73.1 | 51.7 | 94.5 | 51.7 |
| 5DXH30FMK3IHAireForce · Multizone Outdoors | 2.5 tons28,400 Btu/h · Non-ducted | 90% | 2.07 | 10.0 | 21.0 | 13.6 | CEE 25CEE 26XcelES CC | 3 | 215746282 | Non-ducted, 2.5 to 3 tons | 71.2 | 70.5 | 72.0 | 70.5 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | DXH36FMK3IH | 2.10 | Non-ducted, 2.5 to 3 tons | 87% | 215746283 |
| Capacity retention at 5°F | UXH48-60MSK3IH | 100% | Ducted, 3.5 to 4.5 tons | 94% | 217138200 |
| HSPF2 | UXH48-60MSK3IH | 10.0 | Ducted, 3.5 to 4.5 tons | 87% | 217138200 |
| SEER2 | DXH24PSK3IH | 26.0 | Non-ducted, 2 tons | 97% | 216011731 |
| EER2 | DXH42FMK3IH | 13.0 | Non-ducted, 3.5 to 4.5 tons | 95% | 215746284 |
| Heating capacity at 5°F | UXH48-60MSK3IH | 54,000 Btu/h | Ducted, 3.5 to 4.5 tons | 98% | 217138201 |
AireForce size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 50.4(50 is the typical model of its size class)AC-18-HP-E-32with ducted air handler AC-18-AH-E-322 of 4 models qualify · AHRI 218729450 | 49.1(50 is the typical model of its size class)AC-18-HP-E-32with ducted air handler AC-18-AH-E-324 of 4 models have all five ratings · AHRI 218729450 |
| Ducted, 2 tons | 48.9(50 is the typical model of its size class)DXH24FMK3IH2 of 6 models qualify · AHRI 215746287 | 55.0(50 is the typical model of its size class)DXH24FMK3IH6 of 6 models have all five ratings · AHRI 215746287 |
| Ducted, 2.5 to 3 tons | 77.3(50 is the typical model of its size class)UXH24-36MSK3IHwith ducted air handler UMD36MSK3IH4 of 13 models qualify · AHRI 217138199 | 68.5(50 is the typical model of its size class)UXH24-36MSK3IHwith ducted air handler UMD36MSK3IH13 of 13 models have all five ratings · AHRI 217138199 |
| Ducted, 3.5 to 4.5 tons | 83.9(50 is the typical model of its size class)UXH48-60MSK3IHwith ducted air handler UMD60MSK3IH3 of 14 models qualify · AHRI 217138201 | 80.0(50 is the typical model of its size class)UXH48-60MSK3IHwith ducted air handler UMD48MSK3IH14 of 14 models have all five ratings · AHRI 217138200 |
| Non-ducted, up to 1.5 tons | 66.1(50 is the typical model of its size class)AC-18Z-E-M215 of 19 models qualify · AHRI 218729434 | 79.1(50 is the typical model of its size class)DXH09PSK3IHwith ductless indoor unit DHH09PUK3IH19 of 19 models have all five ratings · AHRI 216011727 |
| Non-ducted, 2 tons | 68.5(50 is the typical model of its size class)DXH24FMK3IH4 of 6 models qualify · AHRI 215746281 | 73.3(50 is the typical model of its size class)AC-24Z-E-M36 of 6 models have all five ratings · AHRI 218729435 |
| Non-ducted, 2.5 to 3 tons | 77.8(50 is the typical model of its size class)DXH36FMK3IH9 of 11 models qualify · AHRI 215746283 | 71.2(50 is the typical model of its size class)DXH30FMK3IH11 of 11 models have all five ratings · AHRI 215746282 |
| Non-ducted, 3.5 to 4.5 tons | 67.0(50 is the typical model of its size class)DXH42FMK3IH2 of 2 models qualify · AHRI 215746284 | 67.8(50 is the typical model of its size class)DXH42FMK3IH2 of 2 models have all five ratings · AHRI 215746284 |
Newest AireForce certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| AC2042K230R3AAireforce | 3.5 tons42,000 Btu/h · Non-ducted | 2.00 | 74% | 10.0 | 24.0 | CEE 25CEE 26Xcel | 1 | 218858129 |
| AC2036K230R3AAireforce | 3 tons38,000 Btu/h · Non-ducted | 2.00 | 74% | 10.0 | 23.0 | CEE 25CEE 26Xcel | 1 | 218858128 |
| AC2027K230R3AAireforce | 2.5 tons28,000 Btu/h · Non-ducted | 2.00 | 75% | 10.0 | 22.0 | CEE 25CEE 26Xcel | 1 | 218858127 |
| AC2018K230R3AAireforce | 1.5 tons18,000 Btu/h · Non-ducted | 2.00 | 78% | 10.0 | 25.0 | CEE 25CEE 26Xcel | 1 | 218858126 |
| HP1736K230R3AAireforcewith ductless indoor unit AH17W36K230R3A | 3 tons35,000 Btu/h · Non-ducted | 1.80 | 51% | 8.5 | 17.0 | None | 1 | 218858125 |
Compare AireForce