Skip to content

Della vs LG heat pumps

Measured against models of the same size and duct type, LG scores higher on 5 of the 6 ratings. Della has 94 outdoor models, LG has 100 outdoor models.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Della and LG on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, LG scores higher on 5 of the 6 ratings.
  • Della
  • LG
  • Other ranked manufacturers
DellaLG

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingDellaLG
Efficiency index48%median — · 24th ranked56%median — · 10th ranked
COP at 5°F43%median 1.93 · 26th ranked56%median 1.96 · 17th ranked
Capacity retention at 5°F44%median 73% · 21st ranked57%median 74% · 9th ranked
HSPF250%median 9.5 · 16th ranked51%median 9.0 · 14th ranked
SEER255% (higher)median 21.0 · 14th ranked49% (higher)median 20.0 · 17th ranked
EER241%median 11.2 · 23rd ranked64%median 12.3 · 4th ranked
Heating capacity at 5°F46%median 12,250 Btu/h · 21st ranked61%median 15,550 Btu/h · 7th ranked
Outdoor models94100
AHRI certifications1331,179

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardDellaLG
CEE 2025 Tier 1 (Split ASHP)68.1%64 models86%86 models
CEE 2026 Tier 1 (Split ASHP)68.1%64 models82%82 models
CEE Advanced Tier (Split ASHP)0%0 models11%11 models
Xcel Energy Colorado cold-climate ASHP (2025)66%62 models78%78 models
DOE Cold Climate Heat Pump Challenge0%0 models11%11 models
ENERGY STAR Cold Climate43.6%41 models64%64 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 8 groups where both have models
  • Della
  • LG
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeDellaLG
Ducted, up to 1.5 tons3 · index 67%12 · index 54%
Ducted, 2 tons2 · index 46%9 · index 53%
Ducted, 2.5–3 tons6 · index 65%11 · index 62%
Ducted, 3.5–4.5 tons6 · index 54%16 · index 66%
Ducted, 5 tons and upNone2 · index 81%
Non-ducted, up to 1.5 tons60 · index 46%44 · index 46%
Non-ducted, 2 tons13 · index 45%14 · index 50%
Non-ducted, 2.5–3 tons12 · index 42%12 · index 63%
Non-ducted, 3.5–4.5 tons5 · index 44%10 · index 69%
Non-ducted, 5 tons and upNone1 · index 85%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeDellaCold-climate score, best modelLGCold-climate score, best model
Ducted, up to 1.5 tons57.7(50 is the typical model of its size class)048-TLP-MODU-1D23 of 3 models qualify · AHRI 21756863180.4(50 is the typical model of its size class) (higher)KUSXA181Awith ducted air handler MSVT24***852FAA10 of 10 models qualify · AHRI 217581954
Ducted, 2 tons56.4(50 is the typical model of its size class)048-TCQ-MODU-1D32 of 2 models qualify · AHRI 21871873678.1(50 is the typical model of its size class) (higher)ZRUN024GSS010 of 10 models qualify · AHRI 214914956
Ducted, 2.5–3 tons63.1(50 is the typical model of its size class)048-TPH-MODU-1D46 of 6 models qualify · AHRI 21871874087.4(50 is the typical model of its size class) (higher)ZRUM036GSS010 of 10 models qualify · AHRI 214914952
Ducted, 3.5–4.5 tons63.6(50 is the typical model of its size class)048-TCQ-MODU-1D56 of 6 models qualify · AHRI 21871873890.4(50 is the typical model of its size class) (higher)KUMXA481A18 of 18 models qualify · AHRI 215408637
Ducted, 5 tons and upNo models in this size class94.6(50 is the typical model of its size class)KUMXB601A2 of 2 models qualify · AHRI 215402344
Non-ducted, up to 1.5 tons70.9(50 is the typical model of its size class)048-TPH-MODU-1D342 of 60 models qualify · AHRI 21847100786.8(50 is the typical model of its size class) (higher)KUSAL091Awith ductless indoor unit KNSAL091A44 of 44 models qualify · AHRI 216368959
Non-ducted, 2 tons77.5(50 is the typical model of its size class)048-MS-24K2VR-22S-MX-OUTwith ductless indoor unit 048-MS-24K2VR-22S-MX-IN6 of 13 models qualify · AHRI 21804377085.4(50 is the typical model of its size class) (higher)ZRUN024GSS07 of 14 models qualify · AHRI 215223214
Non-ducted, 2.5–3 tons68.0(50 is the typical model of its size class)048-TPH-MODU-1D48 of 12 models qualify · AHRI 21847100893.7(50 is the typical model of its size class) (higher)KUMXA361A12 of 12 models qualify · AHRI 215402345
Non-ducted, 3.5–4.5 tons48.1(50 is the typical model of its size class)048-TPH-MODU-1D64 of 5 models qualify · AHRI 21847101095.9(50 is the typical model of its size class) (higher)KUMXA421A8 of 9 models qualify · AHRI 215402347
Non-ducted, 5 tons and upNo models in this size class84.7(50 is the typical model of its size class)KUMXB601A2 of 2 models qualify · AHRI 215408633

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeDellaAll-around score, best modelLGAll-around score, best model
Ducted, up to 1.5 tons72.9(50 is the typical model of its size class)048-TPH-MODU-1D33 of 3 models have all five ratings · AHRI 21871873978.7(50 is the typical model of its size class) (higher)KUSXA181Awith ducted air handler MSVT24***852FAA10 of 10 models have all five ratings · AHRI 217581954
Ducted, 2 tons54.0(50 is the typical model of its size class)048-TCQ-MODU-1D32 of 2 models have all five ratings · AHRI 21871873679.5(50 is the typical model of its size class) (higher)ZRUN024GSS08 of 8 models have all five ratings · AHRI 214914956
Ducted, 2.5–3 tons79.9(50 is the typical model of its size class)048-TPH-MODU-1D46 of 6 models have all five ratings · AHRI 21871874089.3(50 is the typical model of its size class) (higher)KUMXA361A12 of 12 models have all five ratings · AHRI 215402346
Ducted, 3.5–4.5 tons67.5(50 is the typical model of its size class)048-TLP-MODU-1D56 of 6 models have all five ratings · AHRI 21756863491.2(50 is the typical model of its size class) (higher)KUMXA421A18 of 18 models have all five ratings · AHRI 215402348
Ducted, 5 tons and upNo models in this size class89.5(50 is the typical model of its size class)KUMXB601A2 of 2 models have all five ratings · AHRI 215402344
Non-ducted, up to 1.5 tons82.6(50 is the typical model of its size class)048-TPH-MODU-1D355 of 60 models have all five ratings · AHRI 21847100791.4(50 is the typical model of its size class) (higher)KUSAL091Awith ductless indoor unit KNSAL091A44 of 44 models have all five ratings · AHRI 216368959
Non-ducted, 2 tons68.1(50 is the typical model of its size class)048-MS-24K2VR-22S-MX-OUTwith ductless indoor unit 048-MS-24K2VR-22S-MX-IN12 of 13 models have all five ratings · AHRI 21804377077.2(50 is the typical model of its size class) (higher)ZRUN024GSS014 of 14 models have all five ratings · AHRI 214914954
Non-ducted, 2.5–3 tons83.1(50 is the typical model of its size class)048-TPH-MODU-1D412 of 12 models have all five ratings · AHRI 21847100890.3(50 is the typical model of its size class) (higher)KUSXA301Awith ductless indoor unit KNSCB301A12 of 12 models have all five ratings · AHRI 214826535
Non-ducted, 3.5–4.5 tons70.2(50 is the typical model of its size class)048-TPH-MODU-1D65 of 5 models have all five ratings · AHRI 21847101089.3(50 is the typical model of its size class) (higher)KUMXA421A9 of 9 models have all five ratings · AHRI 215402347
Non-ducted, 5 tons and upNo models in this size class85.4(50 is the typical model of its size class)ZRUM060GSS02 of 2 models have all five ratings · AHRI 214914943

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingDellaLG
COP at 5°Fbeats 89% · 2.27048-MS-24K2VR-21S-OUTNon-ducted, 2 tonsbeats 100% · 3.17KUSXB181ADucted, up to 1.5 tons
Capacity retention at 5°Fbeats 95% · 105%048-TPH-MODU-1D3Ducted, up to 1.5 tonsbeats 100% · 137%KUSXA181ADucted, up to 1.5 tons
HSPF2beats 96% · 10.5048-TPH-MODU-1D4Ducted, 2.5–3 tonsbeats 97% · 13.5KUSAL091ANon-ducted, up to 1.5 tons
SEER2beats 99% · 26.5048-TPH-MODU-1D4Non-ducted, 2.5–3 tonsbeats 98% · 23.0ZRUM060GSS0Non-ducted, 5 tons and up
EER2beats 97% · 14.0048-TPH-MODU-1D4Non-ducted, 2.5–3 tonsbeats 100% · 14.8ZRUN024GSS0Ducted, 2 tons
Heating capacity at 5°Fbeats 98% · 19,800 Btu/h048-TPH-MODU-1D3Non-ducted, up to 1.5 tonsbeats 100% · 25,000 Btu/hKUSXA181ADucted, up to 1.5 tons

More comparisons