Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Innovair vs ZERO heat pumps
Measured against models of the same size and duct type, Innovair scores higher on 6 of the 6 ratings. Innovair has 126 outdoor models, ZERO has 119 outdoor models. ZERO has no QMID on file and is not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Innovair
- ZERO
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Innovair | ZERO |
|---|---|---|
| Efficiency index | 58% (higher)median — · 8th ranked | 53% (higher)median — |
| COP at 5°F | 58% (higher)median 2.00 · 12th ranked | 45% (higher)median 1.94 |
| Capacity retention at 5°F | 60% (higher)median 78% · 7th ranked | 52% (higher)median 74% |
| HSPF2 | 61% (higher)median 9.5 · 8th ranked | 57% (higher)median 9.5 |
| SEER2 | 60% (higher)median 20.0 · 9th ranked | 58% (higher)median 19.0 |
| EER2 | 51% (higher)median 11.7 · 16th ranked | 48% (higher)median 11.7 |
| Heating capacity at 5°F | 60% (higher)median 19,000 Btu/h · 9th ranked | 55% (higher)median 18,750 Btu/h |
| Outdoor models | 126 | 119 |
| AHRI certifications | 484 | 164 |
Share of models meeting each standard
| Standard | Innovair | ZERO |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 82.5%104 models | 70.6%84 models |
| CEE 2026 Tier 1 (Split ASHP) | 80.2%101 models | 69.7%83 models |
| CEE Advanced Tier (Split ASHP) | 1.6%2 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 78.6%99 models | 64.7%77 models |
| DOE Cold Climate Heat Pump Challenge | 1.6%2 models | 0%0 models |
| ENERGY STAR Cold Climate | 69%87 models | 52.9%63 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Innovair
- ZERO
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Innovair | ZERO |
|---|---|---|
| Ducted, up to 1.5 tons | 19 · index 70% | 7 · index 68% |
| Ducted, 2 tons | 11 · index 59% | 13 · index 51% |
| Ducted, 2.5–3 tons | 26 · index 62% | 20 · index 54% |
| Ducted, 3.5–4.5 tons | 23 · index 64% | 26 · index 54% |
| Ducted, 5 tons and up | 4 · index 63% | 2 · index 64% |
| Non-ducted, up to 1.5 tons | 48 · index 53% | 39 · index 53% |
| Non-ducted, 2 tons | 9 · index 52% | 9 · index 50% |
| Non-ducted, 2.5–3 tons | 20 · index 54% | 13 · index 45% |
| Non-ducted, 3.5–4.5 tons | 12 · index 52% | 6 · index 52% |
| Non-ducted, 5 tons and up | 2 · index 59% | 2 · index 27% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | InnovairCold-climate score, best model | ZEROCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.7(50 is the typical model of its size class) (higher)SHV18H2BAwith ducted air handler SWV18BDA16 of 18 models qualify · AHRI 216027612 | 72.6(50 is the typical model of its size class)Z4SOV-18HDMB-USAlso listed as Z3SOV-18HDMB-US5 of 7 models qualify · AHRI 217138401 |
| Ducted, 2 tons | 85.7(50 is the typical model of its size class) (higher)MOS24H2BH0Awith ducted air handler MDH24H2MHWA10 of 12 models qualify · AHRI 215725473 | 70.4(50 is the typical model of its size class)ZRRV07HPBYFC-18SAlso listed as ZPRVO7HPBYFC-18S, ZPRV07HPBYFC-18S11 of 13 models qualify · AHRI 217904930 |
| Ducted, 2.5–3 tons | 83.2(50 is the typical model of its size class) (higher)MOS36H2BH0Awith ducted air handler MDH36H2MHWA22 of 26 models qualify · AHRI 215735335 | 82.5(50 is the typical model of its size class)Z4SOV-36HDMB-USHH13 of 20 models qualify · AHRI 217752806 |
| Ducted, 3.5–4.5 tons | 82.7(50 is the typical model of its size class)MOM48H2BH6AAlso listed as MOM48H2BH6B20 of 23 models qualify · AHRI 215725526 | 82.7(50 is the typical model of its size class)Z4SOV-48HDMB-USHH19 of 26 models qualify · AHRI 217752809 |
| Ducted, 5 tons and up | 58.3(50 is the typical model of its size class)PXV60H2A1 of 4 models qualify · AHRI 217753792 | None on this board (0 of 2 models qualify) |
| Non-ducted, up to 1.5 tons | 96.7(50 is the typical model of its size class) (higher)MOS06H2BH0Awith ductless indoor unit MHW06H2BHRB38 of 48 models qualify · AHRI 215725442 | 85.9(50 is the typical model of its size class)ZMSB-09HV-USHHR2-Owith ductless indoor unit ZMSB-09HV-USHHR2-I31 of 39 models qualify · AHRI 216097679 |
| Non-ducted, 2 tons | 89.4(50 is the typical model of its size class) (higher)MOS24H2BH0Awith ductless indoor unit MCS24H2BHRA9 of 9 models qualify · AHRI 217230001 | 77.2(50 is the typical model of its size class)ZMSB-24HV-USHHCR2-Owith ductless indoor unit ZMSB-24HV-USHHCR2-I7 of 9 models qualify · AHRI 216097676 |
| Non-ducted, 2.5–3 tons | 89.4(50 is the typical model of its size class) (higher)MOS36H2BH0Awith ductless indoor unit MFC36H2BHRA16 of 20 models qualify · AHRI 217230015 | 72.6(50 is the typical model of its size class)Z4SOV-36HDMB-USHH9 of 13 models qualify · AHRI 217752807 |
| Non-ducted, 3.5–4.5 tons | 73.4(50 is the typical model of its size class) (higher)MOM48H2BH6AAlso listed as MOM48H2BH6B11 of 12 models qualify · AHRI 215725527 | 69.9(50 is the typical model of its size class)Z4SOV-53HDMB-USHH6 of 6 models qualify · AHRI 217752813 |
| Non-ducted, 5 tons and up | None on this board (0 of 2 models qualify) | None on this board (0 of 2 models qualify) |
All-around best
| Size and duct type | InnovairAll-around score, best model | ZEROAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.7(50 is the typical model of its size class) (higher)MOS09H2BH0Awith ducted air handler MDL09H2MHWA17 of 18 models have all five ratings · AHRI 215725467 | 77.4(50 is the typical model of its size class)Z4SOV-18HDMB-USHH6 of 7 models have all five ratings · AHRI 217752800 |
| Ducted, 2 tons | 79.6(50 is the typical model of its size class)GOV36H2BAwith ducted air handler GAV24B2A10 of 11 models have all five ratings · AHRI 215318726 | 79.6(50 is the typical model of its size class)ZOV-24HDGBwith ducted air handler ZAV-24HDGB12 of 13 models have all five ratings · AHRI 217619841 |
| Ducted, 2.5–3 tons | 83.6(50 is the typical model of its size class)MOM36H2BH5AAlso listed as MOM36H2BH5B25 of 27 models have all five ratings · AHRI 215725523 | 83.6(50 is the typical model of its size class)Z4SOV-36HDMB-USHH18 of 20 models have all five ratings · AHRI 217752806 |
| Ducted, 3.5–4.5 tons | 85.1(50 is the typical model of its size class)MOM48H2BM6AAlso listed as MOM48H2BM6B20 of 23 models have all five ratings · AHRI 215725499 | 85.1(50 is the typical model of its size class)Z4SOV-48HDMB-USAlso listed as Z6SOV-48HDMB-US23 of 26 models have all five ratings · AHRI 217138410 |
| Ducted, 5 tons and up | 67.5(50 is the typical model of its size class) (higher)MOS60H2BM0Awith ducted air handler MDH60H2MHWA4 of 4 models have all five ratings · AHRI 215725466 | 64.7(50 is the typical model of its size class)Z4SOV-60HDMB-US2 of 2 models have all five ratings · AHRI 217138413 |
| Non-ducted, up to 1.5 tons | 96.2(50 is the typical model of its size class) (higher)MOS06H2BH0Awith ductless indoor unit MHW06H2BHRB48 of 48 models have all five ratings · AHRI 215725442 | 86.7(50 is the typical model of its size class)ZMSB-09HV-USHHR2-Owith ductless indoor unit ZMSB-09HV-USHHR2-I39 of 39 models have all five ratings · AHRI 216097679 |
| Non-ducted, 2 tons | 86.8(50 is the typical model of its size class) (higher)MOS24H2BM0Awith ductless indoor unit MHW24H2BHRB9 of 9 models have all five ratings · AHRI 215725441 | 74.3(50 is the typical model of its size class)ZMSB-24HV-USHHR2-Owith ductless indoor unit ZMSB-24HV-USHHR2-I9 of 9 models have all five ratings · AHRI 216097682 |
| Non-ducted, 2.5–3 tons | 78.3(50 is the typical model of its size class) (higher)MOM36H2BH5AAlso listed as MOM36H2BH5B20 of 20 models have all five ratings · AHRI 215725522 | 66.3(50 is the typical model of its size class)Z4SOV-36HDMB-USHH13 of 13 models have all five ratings · AHRI 217752805 |
| Non-ducted, 3.5–4.5 tons | 75.6(50 is the typical model of its size class) (higher)MOM48H2BH6AAlso listed as MOM48H2BH6B12 of 12 models have all five ratings · AHRI 215725525 | 62.6(50 is the typical model of its size class)Z4SOV-53HDMB-USHH6 of 6 models have all five ratings · AHRI 217752811 |
| Non-ducted, 5 tons and up | 58.6(50 is the typical model of its size class) (higher)MOM60H2BM6AAlso listed as MOM60H2BM6B2 of 2 models have all five ratings · AHRI 215835696 | 32.5(50 is the typical model of its size class)Z4SOV-60HDMB-USAlso listed as Z6SOV-60HDMB-US2 of 2 models have all five ratings · AHRI 217138412 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Innovair | ZERO |
|---|---|---|
| COP at 5°F | beats 100% · 2.80MOM27H2XE3ANon-ducted, 2.5–3 tons | beats 99% · 2.80ZOU-42HDCA-S14Ducted, 3.5–4.5 tons |
| Capacity retention at 5°F | beats 100% · 133%QOS09H2BH0ADucted, up to 1.5 tons | beats 97% · 103%ZRRV07HPBYFC-18SAlso listed as ZPRVO7HPBYFC-18S, ZPRV07HPBYFC-18SDucted, 2 tons |
| HSPF2 | beats 99% · 14.8MOS06H2BH0ANon-ducted, up to 1.5 tons | beats 99% · 11.0Z4SOV-48HDMB-USHHDucted, 3.5–4.5 tons |
| SEER2 | beats 99% · 22.0POM27H2BM3ADucted, 2.5–3 tons | beats 99% · 22.0Z3SOV-27HDTB-USDucted, 2.5–3 tons |
| EER2 | beats 99% · 18.0MOS06H2BH0ANon-ducted, up to 1.5 tons | beats 93% · 13.3ZOV-24HDGBDucted, 2 tons |
| Heating capacity at 5°F | beats 98% · 19,600 Btu/hSHV18H2BADucted, up to 1.5 tons | beats 97% · 39,000 Btu/hZSOVA-36HDMB-USHHDucted, 2.5–3 tons |