Skip to content

BROCK vs ZOKOP heat pumps

Measured against models of the same size and duct type, ZOKOP scores higher on 4 of the 6 ratings. BROCK has 36 outdoor models, ZOKOP has 37 outdoor models. BROCK and ZOKOP have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BROCK and ZOKOP on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, ZOKOP scores higher on 4 of the 6 ratings.
  • BROCK
  • ZOKOP
  • Other ranked manufacturers
BROCKZOKOP

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBROCKZOKOP
Efficiency index35% (higher)median —34% (higher)median —
COP at 5°F41% (higher)median 1.8034% (higher)median 1.80
Capacity retention at 5°F13%median 41%33%median 72%
HSPF224%median 6.746%median 9.5
SEER224%median 13.436%median 20.0
EER264% (higher)median 11.126% (higher)median 10.5
Heating capacity at 5°F17%median 17,000 Btu/h40%median 9,500 Btu/h
Outdoor models3637
AHRI certifications3,77037

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBROCKZOKOP
CEE 2025 Tier 1 (Split ASHP)19.4%7 models67.6%25 models
CEE 2026 Tier 1 (Split ASHP)11.1%4 models67.6%25 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models56.8%21 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 0 groups where both have models
  • BROCK
  • ZOKOP
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBROCKZOKOP
Ducted, up to 1.5 tons2 · index 45%None
Ducted, 2 tons4 · index 35%None
Ducted, 2.5–3 tons11 · index 35%None
Ducted, 3.5–4.5 tons17 · index 31%None
Ducted, 5 tons and up2 · index 61%None
Non-ducted, up to 1.5 tonsNone27 · index 31%
Non-ducted, 2 tonsNone3 · index 35%
Non-ducted, 2.5–3 tonsNone6 · index 52%
Non-ducted, 3.5–4.5 tonsNone1 · index 27%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBROCKCold-climate score, best modelZOKOPCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 2 models qualify)No models in this size class
Ducted, 2 tonsNone on this board (0 of 4 models qualify)No models in this size class
Ducted, 2.5–3 tonsNone on this board (0 of 11 models qualify)No models in this size class
Ducted, 3.5–4.5 tonsNone on this board (0 of 17 models qualify)No models in this size class
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class68.6(50 is the typical model of its size class)TMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-O14 of 27 models qualify · AHRI 216020699
Non-ducted, 2 tonsNo models in this size classNone on this board (0 of 3 models qualify)
Non-ducted, 2.5–3 tonsNo models in this size class57.5(50 is the typical model of its size class)TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-O6 of 6 models qualify · AHRI 216020700
Non-ducted, 3.5–4.5 tonsNo models in this size class24.7(50 is the typical model of its size class)ZP42M2/19-O1 of 1 models qualify · AHRI 218035871

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBROCKAll-around score, best modelZOKOPAll-around score, best model
Ducted, up to 1.5 tons48.3(50 is the typical model of its size class)PH5SAN519**AA*with indoor coil CAA**1917AM and furnace PG92MSAA42060B2 of 2 models have all five ratings · AHRI 217702474No models in this size class
Ducted, 2 tons60.6(50 is the typical model of its size class)PH8TAN524**AA*with indoor coil CAA**3721AM and furnace PG80MSUA48060B4 of 4 models have all five ratings · AHRI 215647876No models in this size class
Ducted, 2.5–3 tons66.7(50 is the typical model of its size class)PH8TAN536**AA*with ducted air handler PF5TNBD60L11 of 11 models have all five ratings · AHRI 215628948No models in this size class
Ducted, 3.5–4.5 tons72.7(50 is the typical model of its size class)PH8TAN548**AA*with ducted air handler QFVA5D6021X16 of 16 models have all five ratings · AHRI 218695444No models in this size class
Ducted, 5 tons and up80.2(50 is the typical model of its size class)PH8TAN560**AA*with ducted air handler PF5TNBD60L3 of 3 models have all five ratings · AHRI 215560743No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class72.2(50 is the typical model of its size class)TMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-O27 of 27 models have all five ratings · AHRI 216020699
Non-ducted, 2 tonsNo models in this size class39.1(50 is the typical model of its size class)TSC-24HA2/I2XI18B-Owith ductless indoor unit TSC-24HA2/I2XI18B-IAlso listed as TSC-24HA2/I2XI18B-O3 of 3 models have all five ratings · AHRI 216020695
Non-ducted, 2.5–3 tonsNo models in this size class65.1(50 is the typical model of its size class)TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-O6 of 6 models have all five ratings · AHRI 216020700
Non-ducted, 3.5–4.5 tonsNo models in this size class27.2(50 is the typical model of its size class)ZP42M2/19-O1 of 1 models have all five ratings · AHRI 218035871

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBROCKZOKOP
COP at 5°Fbeats 92% · 2.48PH8TAN536**AA*Ducted, 2.5–3 tonsbeats 71% · 2.10TSC-24HA2/I2XI18B-OAlso listed as TSC-24HA2/I2XI18B-ONon-ducted, 2 tons
Capacity retention at 5°Fbeats 41% · 52%PH5SAN560**AA*Also listed as PH5SAP560**AADucted, 5 tons and upbeats 61% · 80%TMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-ONon-ducted, up to 1.5 tons
HSPF2beats 58% · 8.5PH8TAN548**AA*Ducted, 3.5–4.5 tonsbeats 80% · 10.5TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-ONon-ducted, 2.5–3 tons
SEER2beats 81% · 17.5PH8TAN560**AA*Ducted, 5 tons and upbeats 91% · 24.0TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-ONon-ducted, 2.5–3 tons
EER2beats 99% · 13.5PH8TAN548**AA*Ducted, 3.5–4.5 tonsbeats 70% · 13.0TMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-ONon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 44% · 8,600 Btu/hPH5SAN518**AA*Ducted, up to 1.5 tonsbeats 88% · 16,000 Btu/hTMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-ONon-ducted, up to 1.5 tons

More comparisons