Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CLASSIC vs NOVAIR: heat pump ratings compared
Against heat pumps of the same size and type, a typical CLASSIC model beats 52% and a typical NOVAIR model 63%. NOVAIR rates higher overall.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
CLASSIC
52%
of similar heat pumps beaten by its typical model
About average32 models listed
NOVAIR
63%
of similar heat pumps beaten by its typical model
Well above average25 models listed
- Efficiency on a 5°F dayCOP at 5°FCLASSIC: Beats 41%NOVAIR: Beats 48%
- Heating power kept at 5°FCapacity at 5°F vs 47°FCLASSIC: Beats 42%NOVAIR: Beats 64%
- Winter-long heating efficiencyHSPF2CLASSIC: Beats 51%NOVAIR: Beats 73%
- Summer-long cooling efficiencySEER2CLASSIC: Beats 52%NOVAIR: Beats 69%
- Hot-day cooling efficiencyEER2CLASSIC: Beats 49%NOVAIR: Beats 60%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- CLASSIC
- 56%
- NOVAIR
- 88%
Xcel CC
- CLASSIC
- 41%
- NOVAIR
- 80%
CEE Advanced
- CLASSIC
- 0%
- NOVAIR
- 0%
ENERGY STAR CC
- CLASSIC
- 13%
- NOVAIR
- 80%
Top cold-climate picks, ducted up to 1.5 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
CLASSIC
- 1MRSVHC12ASwith ducted air handler MFCHC12SCLASSIC1 ton · 11,500 Btu/h · DuctedKeeps 70% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.26 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.3 (HSPF2)
- Great
- 2MMRSHC18AS2CLASSIC1.5 tons · 18,000 Btu/h · DuctedKeeps 74% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.86 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 9.8 (HSPF2)
- Good
NOVAIR
- 1LEA18-EVOX-30-Owith ducted air handler LEA-18/24-ACOIL-410ANOVAIR1.5 tons · 18,000 Btu/h · DuctedKeeps 79% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 79% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Seasonal efficiency
- 9.5 (HSPF2)
- Good
- 2LEA18MZ-2P-25SK-ONOVAIR1.5 tons · 18,000 Btu/h · DuctedKeeps 70% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.8 (HSPF2)
- Good
- 3LEA20MZ-2P-35SK-ONOVAIRAlso listed as LEA20MZ-2P-35SK-O1.5 tons · 19,000 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.83 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 9.3 (HSPF2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view