Conforto vs ROYALTON: heat pump ratings compared
Against heat pumps of the same size and type, a typical Conforto model beats 58% and a typical ROYALTON model 50%. Conforto rates higher overall.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
Conforto
58%
of similar heat pumps beaten by its typical model
Above average21 models listed
ROYALTON
50%
of similar heat pumps beaten by its typical model
About average21 models listed
- Efficiency on a 5°F dayCOP at 5°FConforto: Beats 49%ROYALTON: Beats 58%
- Heating power kept at 5°FCapacity at 5°F vs 47°FConforto: Beats 67%ROYALTON: Beats 20%
- Winter-long heating efficiencyHSPF2Conforto: Beats 70%ROYALTON: Beats 22%
- Summer-long cooling efficiencySEER2Conforto: Beats 59%ROYALTON: Beats 29%
- Hot-day cooling efficiencyEER2Conforto: Beats 50%ROYALTON: Beats 67%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Conforto
- 71%
- ROYALTON
- 19%
Xcel CC
- Conforto
- 67%
- ROYALTON
- 0%
CEE Advanced
- Conforto
- 0%
- ROYALTON
- 0%
ENERGY STAR CC
- Conforto
- 76%
- ROYALTON
- 0%
All-around best, ducted 2.5–3 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, 2.5–3 tons (27,000–38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?
Conforto
- 1MHMZ327DAConforto2.5 tons · 28,000 Btu/h · DuctedCold-climate pick, score 66.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 89% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Good
- 2MHMZ436DAConforto3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 63.7Meets none of the standards tracked here
- Heat kept at 5°F
- 89% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.70 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.0 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 11.7 (EER2)
- Good
- 3MHSD136DACFCwith ducted air handler MHAH136DACFCConforto3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 78.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 86% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.97 (COP at 5°F)
- Good
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 16.0 (SEER2)
- Good
- Hot-day cooling
- 10.0 (EER2)
- Below the middle
ROYALTON
- 14HP17L36P-**Awith indoor coil EAD4X-48C+TDR and furnace 80G1DF110CE20ROYALTON3 tons · 36,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 53% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.34 (COP at 5°F)
- Great
- Winter efficiency
- 8.7 (HSPF2)
- Good
- Cooling efficiency
- 16.6 (SEER2)
- Good
- Hot-day cooling
- 13.0 (EER2)
- Top 10%
- 24HP17L30P-**Awith indoor coil EAD4X-42B+TDR and furnace 80G1DF090BE16ROYALTON2.5 tons · 29,800 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 49% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.34 (COP at 5°F)
- Great
- Winter efficiency
- 8.6 (HSPF2)
- Good
- Cooling efficiency
- 16.2 (SEER2)
- Good
- Hot-day cooling
- 13.5 (EER2)
- Top 10%
- 3PRPHP1636VP-**ROYALTON3 tons · 34,200 Btu/h · DuctedNot a cold-climate pick: keeps 41% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 42% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.60 (COP at 5°F)
- Below the middle
- Winter efficiency
- 6.7 (HSPF2)
- Below the middle
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 11.5 (EER2)
- Good