Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
DIAMONDAIR vs NOVAIR: heat pump ratings compared
Against heat pumps of the same size and type, a typical DIAMONDAIR model beats 42% and a typical NOVAIR model 63%. NOVAIR rates higher overall.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
DIAMONDAIR
42%
of similar heat pumps beaten by its typical model
Below average25 models listed
NOVAIR
63%
of similar heat pumps beaten by its typical model
Well above average25 models listed
- Efficiency on a 5°F dayCOP at 5°FDIAMONDAIR: Beats 30%NOVAIR: Beats 48%
- Heating power kept at 5°FCapacity at 5°F vs 47°FDIAMONDAIR: Beats 34%NOVAIR: Beats 64%
- Winter-long heating efficiencyHSPF2DIAMONDAIR: Beats 42%NOVAIR: Beats 73%
- Summer-long cooling efficiencySEER2DIAMONDAIR: Beats 38%NOVAIR: Beats 69%
- Hot-day cooling efficiencyEER2DIAMONDAIR: Beats 53%NOVAIR: Beats 60%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- DIAMONDAIR
- 36%
- NOVAIR
- 88%
Xcel CC
- DIAMONDAIR
- 24%
- NOVAIR
- 80%
CEE Advanced
- DIAMONDAIR
- 0%
- NOVAIR
- 0%
ENERGY STAR CC
- DIAMONDAIR
- 0%
- NOVAIR
- 80%
Top cold-climate picks, ductless up to 1.5 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ductless, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
DIAMONDAIR
- 1D2009SHO2with ductless indoor unit DF2009HMSI2DIAMONDAIR1 ton · 9,000 Btu/h · DuctlessKeeps 94% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 94% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 11.6 (HSPF2)
- Top 10%
- 2D2018SHO2with ductless indoor unit DF2018HMSI2DIAMONDAIR1.5 tons · 18,000 Btu/h · DuctlessKeeps 96% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 96% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.89 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.6 (HSPF2)
- Great
- 3D2012SHO2with ductless indoor unit DF2012HMSI2DIAMONDAIR1 ton · 12,000 Btu/h · DuctlessKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.89 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.5 (HSPF2)
- Great
NOVAIR
- 1LEA09SZ25SK-Owith ductless indoor unit 2LEA06UUSK-INOVAIR0.5 tons · 6,000 Btu/h · DuctlessKeeps 107% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 107% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.09 (COP at 5°F)
- Great
- Seasonal efficiency
- 13.6 (HSPF2)
- Top 10%
- 2LEA12SZ25SK-Owith ductless indoor unit LEA12UUSK-INOVAIR1 ton · 12,000 Btu/h · DuctlessKeeps 74% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.25 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 10.8 (HSPF2)
- Great
- 3LEA09SZ35SK-Owith ductless indoor unit 2LEA09UUSK-INOVAIR1 ton · 9,000 Btu/h · DuctlessKeeps 88% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 88% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.97 (COP at 5°F)
- Good
- Seasonal efficiency
- 11.5 (HSPF2)
- Top 10%
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view