Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
ECO-AIR vs PolarWave: heat pump ratings compared
Against heat pumps of the same size and type, a typical ECO-AIR model beats 56% and a typical PolarWave model 54%. ECO-AIR rates slightly higher overall.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
ECO-AIR
56%
of similar heat pumps beaten by its typical model
Above average58 models listed
PolarWave
54%
of similar heat pumps beaten by its typical model
About average58 models listed
- Efficiency on a 5°F dayCOP at 5°FECO-AIR: Beats 51%PolarWave: Beats 44%
- Heating power kept at 5°FCapacity at 5°F vs 47°FECO-AIR: Beats 53%PolarWave: Beats 57%
- Winter-long heating efficiencyHSPF2ECO-AIR: Beats 69%PolarWave: Beats 66%
- Summer-long cooling efficiencySEER2ECO-AIR: Beats 62%PolarWave: Beats 59%
- Hot-day cooling efficiencyEER2ECO-AIR: Beats 47%PolarWave: Beats 43%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- ECO-AIR
- 62%
- PolarWave
- 60%
Xcel CC
- ECO-AIR
- 45%
- PolarWave
- 41%
CEE Advanced
- ECO-AIR
- 2%
- PolarWave
- 2%
ENERGY STAR CC
- ECO-AIR
- 50%
- PolarWave
- 47%
Top cold-climate picks, ducted 3.5–4.5 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, 3.5–4.5 tons (39,000–56,999 Btu/h cooling). What size is my system?
ECO-AIR
- 1MOE30U-48HFN1-M-[X](GA)with ducted air handler MTI-48HWFN1-MECO-AIR4 tons · 48,000 Btu/h · DuctedKeeps 88% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 88% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.02 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.3 (HSPF2)
- Top 10%
- 2M5OG-48HFN1-M-[X]ECO-AIR (sold as Eco Air)4 tons · 47,000 Btu/h · DuctedKeeps 87% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 87% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.0 (HSPF2)
- Good
- 3MOE30U-48HFN1-M-[X1]with ducted air handler MVC-48HWFN1-MECO-AIR4 tons · 47,000 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 9.4 (HSPF2)
- Great
PolarWave
- 1ACIQ-48ZPL-HP230Bwith ducted air handler ACIQ-48CD-HH-MBPolarWave4 tons · 48,000 Btu/h · DuctedKeeps 88% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 88% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.02 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.3 (HSPF2)
- Top 10%
- 2ACIQ-60ZPL-HP230Bwith ducted air handler ACIQ-60CD-HH-MBPolarWave4.5 tons · 55,000 Btu/h · DuctedKeeps 93% of its heat at 5°FMeets ENERGY STAR CC
- Heat kept at 5°F
- 93% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.97 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.5 (HSPF2)
- Top 10%
- 3EZ-60-HPwith ducted air handler EZ-60-AHPolarWave4.5 tons · 55,000 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.91 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 9.4 (HSPF2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view