Skip to content

GE Appliances vs Samsung: heat pump ratings compared

Against heat pumps of the same size and type, a typical GE Appliances model beats 49% and a typical Samsung model 62%. Samsung rates higher overall.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

GE Appliances

49%

of similar heat pumps beaten by its typical model

About average

66 models listed

Samsung

62%

of similar heat pumps beaten by its typical model

Well above average

55 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FGE Appliances: Beats 42%Samsung: Beats 48%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FGE Appliances: Beats 45%Samsung: Beats 84%
  • Winter-long heating efficiencyHSPF2GE Appliances: Beats 50%Samsung: Beats 55%
  • Summer-long cooling efficiencySEER2GE Appliances: Beats 46%Samsung: Beats 64%
  • Hot-day cooling efficiencyEER2GE Appliances: Beats 50%Samsung: Beats 58%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    GE Appliances
    62%
    Samsung
    86%
  • Xcel CC

    GE Appliances
    36%
    Samsung
    89%
  • CEE Advanced

    GE Appliances
    0%
    Samsung
    9%
  • ENERGY STAR CC

    GE Appliances
    27%
    Samsung
    9%

All-around best, ducted 2.5–3 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

Showing Ducted, 2.5–3 tons (27,000–38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

GE Appliances

  1. 1NS22H36MA4-**Awith indoor coil D(A,C,E)36D44+TDR and furnace NF97D070M3B-GE Appliances (sold as GE)3 tons · 34,000 Btu/h · DuctedNot a cold-climate pick: keeps 65% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.78 (COP at 5°F)
    Top 10%
    Winter efficiency
    9.4 (HSPF2)
    Great
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    12.0 (EER2)
    Great
    83.2score / 100Heating 76 · Cooling 90
  2. 2NS17H36SA4-**Awith indoor coil D(A,C,E)48D44+TDR and furnace NF80D110S5C-GE Appliances (sold as GE)3 tons · 35,400 Btu/h · DuctedNot a cold-climate pick: keeps 68% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    69% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.89 (COP at 5°F)
    Top 10%
    Winter efficiency
    8.5 (HSPF2)
    Good
    Cooling efficiency
    17.0 (SEER2)
    Good
    Hot-day cooling
    13.0 (EER2)
    Top 10%
    77.1score / 100Heating 70 · Cooling 84
  3. 3NS17H30SA4-**Awith indoor coil CH36B34+TDR and furnace NF80U090S5C-GE Appliances (sold as GE)2.5 tons · 28,600 Btu/h · DuctedNot a cold-climate pick: keeps 65% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    65% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.68 (COP at 5°F)
    Top 10%
    Winter efficiency
    8.2 (HSPF2)
    Good
    Cooling efficiency
    16.2 (SEER2)
    Good
    Hot-day cooling
    13.1 (EER2)
    Top 10%
    73.0score / 100Heating 65 · Cooling 81

Samsung

  1. 1AJ030CXS4CHSamsung2.5 tons · 28,400 Btu/h · DuctedCold-climate pick, score 72.2Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    101% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.81 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    13.0 (EER2)
    Top 10%
    83.8score / 100Heating 72 · Cooling 95
  2. 2AC036BXSCCHwith ducted air handler AC036BNHDCHSamsung3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 72.2Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    99% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.94 (COP at 5°F)
    Good
    Winter efficiency
    8.8 (HSPF2)
    Good
    Cooling efficiency
    19.4 (SEER2)
    Great
    Hot-day cooling
    12.2 (EER2)
    Top 10%
    81.1score / 100Heating 72 · Cooling 90
  3. 3AC030BXSCCHwith ducted air handler AC030BNZDCHSamsung2.5 tons · 30,000 Btu/h · DuctedCold-climate pick, score 67.0Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    113% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.84 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.6 (HSPF2)
    Good
    Cooling efficiency
    18.5 (SEER2)
    Great
    Hot-day cooling
    12.5 (EER2)
    Top 10%
    77.6score / 100Heating 67 · Cooling 88

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view