Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
iFLOW vs TK'S: heat pump ratings compared
Against heat pumps of the same size and type, a typical iFLOW model beats 43% and a typical TK'S model 48%. TK'S rates higher overall.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
iFLOW
43%
of similar heat pumps beaten by its typical model
Below average14 models listed
TK'S
48%
of similar heat pumps beaten by its typical model
About average15 models listed
- Efficiency on a 5°F dayCOP at 5°FiFLOW: Beats 44%TK'S: Beats 34%
- Heating power kept at 5°FCapacity at 5°F vs 47°FiFLOW: Beats 57%TK'S: Beats 31%
- Winter-long heating efficiencyHSPF2iFLOW: Beats 70%TK'S: Beats 58%
- Summer-long cooling efficiencySEER2iFLOW: Beats 36%TK'S: Beats 64%
- Hot-day cooling efficiencyEER2iFLOW: Beats 21%TK'S: Beats 47%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- iFLOW
- 14%
- TK'S
- 67%
Xcel CC
- iFLOW
- 50%
- TK'S
- 20%
CEE Advanced
- iFLOW
- 0%
- TK'S
- 0%
ENERGY STAR CC
- iFLOW
- 0%
- TK'S
- 0%
Top cold-climate picks, ducted 2.5–3 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, 2.5–3 tons (27,000–38,999 Btu/h cooling). What size is my system?
iFLOW
- 170HPIC36Awith ducted air handler 70C3036CAiFLOW3 tons · 35,000 Btu/h · DuctedKeeps 82% of its heat at 5°FMeets Xcel CC
- Heat kept at 5°F
- 82% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.0 (HSPF2)
- Top 10%
- 270HPIC30Awith ducted air handler 70C3036CAiFLOW2.5 tons · 30,000 Btu/h · DuctedKeeps 82% of its heat at 5°FMeets Xcel CC
- Heat kept at 5°F
- 82% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.85 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 9.7 (HSPF2)
- Great
- 370HIPC36Swith ducted air handler 70C3036CAiFLOW3 tons · 35,000 Btu/h · DuctedKeeps 83% of its heat at 5°FMeets Xcel CC
- Heat kept at 5°F
- 83% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 8.5 (HSPF2)
- Good
TK'S
- 1T3C-30HFN1*TK'S2.5 tons · 28,000 Btu/h · DuctedKeeps 71% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.83 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 9.2 (HSPF2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view