Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Innovair vs RUSSELL: heat pump ratings compared
Against heat pumps of the same size and type, a typical Innovair model beats 56% and a typical RUSSELL model 49%. Innovair rates higher overall.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
Innovair
56%
of similar heat pumps beaten by its typical model
Above average44 models listed
RUSSELL
49%
of similar heat pumps beaten by its typical model
About average60 models listed
- Efficiency on a 5°F dayCOP at 5°FInnovair: Beats 51%RUSSELL: Beats 80%
- Heating power kept at 5°FCapacity at 5°F vs 47°FInnovair: Beats 64%RUSSELL: Beats 43%
- Winter-long heating efficiencyHSPF2Innovair: Beats 53%RUSSELL: Beats 25%
- Summer-long cooling efficiencySEER2Innovair: Beats 50%RUSSELL: Beats 32%
- Hot-day cooling efficiencyEER2Innovair: Beats 42%RUSSELL: Beats 42%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Innovair
- 52%
- RUSSELL
- 17%
Xcel CC
- Innovair
- 48%
- RUSSELL
- 13%
CEE Advanced
- Innovair
- 0%
- RUSSELL
- 3%
ENERGY STAR CC
- Innovair
- 52%
- RUSSELL
- 22%
Top cold-climate picks, ducted up to 1.5 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
Innovair
- 1SHV18H2R20with ducted air handler WEV18H2R19Innovair1.5 tons · 18,000 Btu/h · DuctedKeeps 99% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 99% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.30 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.8 (HSPF2)
- Top 10%
- 2SHV24H2R20*with ducted air handler MAC24H1418EInnovair1.5 tons · 20,000 Btu/h · DuctedKeeps 80% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 80% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.2 (HSPF2)
- Great
- 3MHD-18with ducted air handler MHD-CC2.0-17.5-MInnovair1.5 tons · 18,000 Btu/h · DuctedKeeps 75% of its heat at 5°FMeets Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 75% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.21 (COP at 5°F)
- Great
- Seasonal efficiency
- 9.5 (HSPF2)
- Good
RUSSELL
None of RUSSELL’s ducted, up to 1.5 tons models qualifies.
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view