Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Nortek Global HVAC vs RUSSELL heat pumps
Measured against models of the same size and duct type, Nortek Global HVAC scores higher on 5 of the 6 ratings. Nortek Global HVAC has 75 outdoor models, RUSSELL has 60 outdoor models. RUSSELL has no QMID on file and is not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Nortek Global HVAC
- RUSSELL
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Nortek Global HVAC | RUSSELL |
|---|---|---|
| Efficiency index | 51% (higher)median — · 20th ranked | 49% (higher)median — |
| COP at 5°F | 44%median 1.85 · 23rd ranked | 80%median 2.20 |
| Capacity retention at 5°F | 64% (higher)median 80% · 4th ranked | 43% (higher)median 57% |
| HSPF2 | 38% (higher)median 8.2 · 22nd ranked | 25% (higher)median 7.2 |
| SEER2 | 39% (higher)median 16.5 · 22nd ranked | 32% (higher)median 14.3 |
| EER2 | 46% (higher)median 11.0 · 21st ranked | 42% (higher)median 10.6 |
| Heating capacity at 5°F | 56% (higher)median 14,500 Btu/h · 10th ranked | 42% (higher)median 24,200 Btu/h |
| Outdoor models | 75 | 60 |
| AHRI certifications | 280 | 1,231 |
Share of models meeting each standard
| Standard | Nortek Global HVAC | RUSSELL |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 38.7%29 models | 16.7%10 models |
| CEE 2026 Tier 1 (Split ASHP) | 38.7%29 models | 16.7%10 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 3.3%2 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 41.3%31 models | 13.3%8 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 3.3%2 models |
| ENERGY STAR Cold Climate | 29.3%22 models | 21.7%13 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Nortek Global HVAC
- RUSSELL
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Nortek Global HVAC | RUSSELL |
|---|---|---|
| Ducted, up to 1.5 tons | 10 · index 47% | 2 · index 27% |
| Ducted, 2 tons | 7 · index 52% | 7 · index 52% |
| Ducted, 2.5–3 tons | 20 · index 55% | 17 · index 52% |
| Ducted, 3.5–4.5 tons | 13 · index 58% | 26 · index 50% |
| Ducted, 5 tons and up | None | 8 · index 70% |
| Non-ducted, up to 1.5 tons | 23 · index 47% | None |
| Non-ducted, 2 tons | 7 · index 53% | None |
| Non-ducted, 2.5–3 tons | 10 · index 56% | None |
| Non-ducted, 3.5–4.5 tons | 1 · index 45% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | Nortek Global HVACCold-climate score, best model | RUSSELLCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 55.9(50 is the typical model of its size class)WHU09SZA21Swith ducted air handler WHU09DHA21S5 of 10 models qualify · AHRI 207237540 | None on this board (0 of 2 models qualify) |
| Ducted, 2 tons | 68.1(50 is the typical model of its size class)WHM24SZA21Swith ducted air handler D(A,C,E)24D44+TDR4 of 6 models qualify · AHRI 214640590 | 74.7(50 is the typical model of its size class) (higher)SP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace S951V0403A17UHU2 of 7 models qualify · AHRI 213372369 |
| Ducted, 2.5–3 tons | 78.1(50 is the typical model of its size class)WHU36SZA21Swith ducted air handler WHU36DHA21S7 of 21 models qualify · AHRI 207237544 | 80.6(50 is the typical model of its size class) (higher)SP18AZ36AJVCwith ducted air handler SHMVZ6021SEACA2 of 17 models qualify · AHRI 210106900 |
| Ducted, 3.5–4.5 tons | 73.0(50 is the typical model of its size class)WHM60SZA21Swith ducted air handler D(A,C,E)60B44+TDR4 of 13 models qualify · AHRI 214640596 | 76.3(50 is the typical model of its size class) (higher)SP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace S962V1005A21M4S4 of 26 models qualify · AHRI 210106968 |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 8 models qualify) |
| Non-ducted, up to 1.5 tons | 78.4(50 is the typical model of its size class)WHU09SZA21Swith ductless indoor unit WHU09CTA21S17 of 23 models qualify · AHRI 207237535 | No models in this size class |
| Non-ducted, 2 tons | 76.1(50 is the typical model of its size class)GXH24(7.0)FMK4DH-15 of 7 models qualify · AHRI 210276801 | No models in this size class |
| Non-ducted, 2.5–3 tons | 77.2(50 is the typical model of its size class)WHU36SZA21Swith ductless indoor unit WHU36CTA21S7 of 10 models qualify · AHRI 207237539 | No models in this size class |
| Non-ducted, 3.5–4.5 tons | 42.0(50 is the typical model of its size class)WHP42M5A21S1 of 1 models qualify · AHRI 208404161 | No models in this size class |
All-around best
| Size and duct type | Nortek Global HVACAll-around score, best model | RUSSELLAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 57.7(50 is the typical model of its size class) (higher)WHU09SZA21Swith ducted air handler WHU09DHA21S5 of 10 models have all five ratings · AHRI 207237540 | 34.5(50 is the typical model of its size class)SP15AZ18AJ2Nwith ducted air handler SH2CZ2417STANN2 of 2 models have all five ratings · AHRI 211627516 |
| Ducted, 2 tons | 71.6(50 is the typical model of its size class)WHP24M3A21S6 of 7 models have all five ratings · AHRI 208404156 | 83.6(50 is the typical model of its size class) (higher)SP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace S951V0403A17UHU4 of 7 models have all five ratings · AHRI 213372369 |
| Ducted, 2.5–3 tons | 78.6(50 is the typical model of its size class)WHP36M4A21S7 of 20 models have all five ratings · AHRI 208404158 | 87.2(50 is the typical model of its size class) (higher)SP18AZ36AJVCwith indoor coil TCFZ6021SEAAM and furnace S802VA100521Z6 of 17 models have all five ratings · AHRI 210589394 |
| Ducted, 3.5–4.5 tons | 65.5(50 is the typical model of its size class)WHM48SZA21Swith ducted air handler DC61A44-245R4 of 13 models have all five ratings · AHRI 213886028 | 80.3(50 is the typical model of its size class) (higher)SP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace S802VA100521Z9 of 26 models have all five ratings · AHRI 210589350 |
| Ducted, 5 tons and up | No models in this size class | 70.2(50 is the typical model of its size class)SP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace S97MV1005A21DHS1 of 8 models have all five ratings · AHRI 212387320 |
| Non-ducted, up to 1.5 tons | 85.4(50 is the typical model of its size class)WHZ09SZA21Swith ductless indoor unit WHZ09WMA21S19 of 24 models have all five ratings · AHRI 207337194 | No models in this size class |
| Non-ducted, 2 tons | 71.5(50 is the typical model of its size class)GXH24(7.0)FMK4DH-16 of 7 models have all five ratings · AHRI 210276801 | No models in this size class |
| Non-ducted, 2.5–3 tons | 70.2(50 is the typical model of its size class)GXH42(12.3)FMK4DH-18 of 10 models have all five ratings · AHRI 210276799 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Nortek Global HVAC | RUSSELL |
|---|---|---|
| COP at 5°F | beats 96% · 2.28WHU36SZA21SNon-ducted, 2.5–3 tons | beats 98% · 2.60SP15AZ60AJ2NDucted, 5 tons and up |
| Capacity retention at 5°F | beats 99% · 113%WHP36M4A21SNon-ducted, 2.5–3 tons | beats 100% · 105%SP18AZ48AJVCDucted, 3.5–4.5 tons |
| HSPF2 | beats 83% · 9.5WHU36SZA21SDucted, 2.5–3 tons | beats 75% · 9.5RD17AZ24AJ3NDucted, 2 tons |
| SEER2 | beats 96% · 27.5WHZ09SZA21SNon-ducted, up to 1.5 tons | beats 94% · 20.0SP18AZ24AJVCDucted, 2 tons |
| EER2 | beats 93% · 15.5WHZ09SZA21SNon-ducted, up to 1.5 tons | beats 91% · 12.5SP18AZ36AJVCDucted, 2.5–3 tons |
| Heating capacity at 5°F | beats 92% · 18,000 Btu/hWHP18M2A21SNon-ducted, up to 1.5 tons | beats 100% · 43,500 Btu/hSP18AZ36AJVCDucted, 2.5–3 tons |