Skip to content

ACIQ vs Friedrich: heat pump ratings compared

Against heat pumps of the same size and type, a typical ACIQ model beats 50% and a typical Friedrich model 39%. ACIQ rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

ACIQ

50%

of similar heat pumps beaten by its typical model

About average

175 models listed

Friedrich

39%

of similar heat pumps beaten by its typical model

Well below average

188 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FACIQ: Beats 55%Friedrich: Beats 46%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FACIQ: Beats 43%Friedrich: Beats 36%
  • Winter-long heating efficiencyHSPF2ACIQ: Beats 52%Friedrich: Beats 31%
  • Summer-long cooling efficiencySEER2ACIQ: Beats 49%Friedrich: Beats 34%
  • Hot-day cooling efficiencyEER2ACIQ: Beats 52%Friedrich: Beats 37%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    ACIQ
    55%
    Friedrich
    27%
  • Xcel CC

    ACIQ
    46%
    Friedrich
    21%
  • CEE Advanced

    ACIQ
    2%
    Friedrich
    1%
  • ENERGY STAR CC

    ACIQ
    34%
    Friedrich
    22%

All-around best, ducted 2 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

ACIQ

  1. 1B5H3V24*K*AAA*with ducted air handler FCMA5B36L0C*+WALLCONACIQ2 tons · 22,800 Btu/h · DuctedCold-climate pick, score 69.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    77% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.06 (COP at 5°F)
    Good
    Winter efficiency
    10.5 (HSPF2)
    Top 10%
    Cooling efficiency
    21.5 (SEER2)
    Top 10%
    Hot-day cooling
    13.0 (EER2)
    Top 10%
    82.9score / 100Heating 70 · Cooling 96
  2. 2ACIQ-24ZS-HP230Cwith ducted air handler ACIQ-24CD-HH-MCACIQ2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 77.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    76% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.30 (COP at 5°F)
    Great
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.5 (EER2)
    Great
    78.8score / 100Heating 77 · Cooling 81
  3. 3N5H9V24*K*AAA*with indoor coil EA*5X37M21A and furnace *80VSL1102122BACIQ2 tons · 24,800 Btu/h · DuctedCold-climate pick, score 72.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    86% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    14.0 (EER2)
    Top 10%
    78.8score / 100Heating 70 · Cooling 88

Friedrich

  1. 1FRP19AY24AJVCwith indoor coil RCFY2421HEAAM and furnace FR951V0603A17M4Friedrich2 tons · 22,800 Btu/h · DuctedCold-climate pick, score 56.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    82% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    21.0 (SEER2)
    Top 10%
    Hot-day cooling
    13.0 (EER2)
    Top 10%
    75.1score / 100Heating 56 · Cooling 94
  2. 2RD18AY24AJVCwith ducted air handler RHMVY2417SEACNFriedrich2 tons · 21,400 Btu/h · DuctedCold-climate pick, score 70.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    84% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Good
    70.1score / 100Heating 69 · Cooling 71
  3. 3FRP17AY24AJVCwith indoor coil RCFY2417STANM and furnace FR962V0603A17M4SFriedrich2 tons · 22,400 Btu/h · DuctedCold-climate pick, score 67.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    82% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Good
    Cooling efficiency
    17.0 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Below the middle
    56.4score / 100Heating 67 · Cooling 46

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view