Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
AIR-CON vs NOVAIR: heat pump ratings compared
Against heat pumps of the same size and type, a typical AIR-CON model beats 45% and a typical NOVAIR model 76%. NOVAIR rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
AIR-CON
45%
of similar heat pumps beaten by its typical model
About average41 models listed
NOVAIR
76%
of similar heat pumps beaten by its typical model
Well above average42 models listed
- Efficiency on a 5°F dayCOP at 5°FAIR-CON: Beats 57%NOVAIR: Beats 59%
- Heating power kept at 5°FCapacity at 5°F vs 47°FAIR-CON: Beats 33%NOVAIR: Beats 75%
- Winter-long heating efficiencyHSPF2AIR-CON: Beats 45%NOVAIR: Beats 80%
- Summer-long cooling efficiencySEER2AIR-CON: Beats 43%NOVAIR: Beats 83%
- Hot-day cooling efficiencyEER2AIR-CON: Beats 39%NOVAIR: Beats 81%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- AIR-CON
- 44%
- NOVAIR
- 98%
Xcel CC
- AIR-CON
- 34%
- NOVAIR
- 100%
CEE Advanced
- AIR-CON
- 0%
- NOVAIR
- 5%
ENERGY STAR CC
- AIR-CON
- 0%
- NOVAIR
- 100%
Top cold-climate picks, ducted up to 1.5 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
AIR-CON
- 1ASGCI8H4M18with ducted air handler ASGEK8H4M18AIR-CON1.5 tons · 17,500 Btu/h · DuctedKeeps 71% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 11.3 (HSPF2)
- Top 10%
NOVAIR
- 1LEA06SZ36-Owith ducted air handler LEA06DUCT-INOVAIR0.5 tons · 6,500 Btu/h · DuctedKeeps 98% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 13.8 (HSPF2)
- Top 10%
- 2LEA18CEN36-Owith ducted air handler LEA18HH-CEN-INOVAIR1.5 tons · 18,000 Btu/h · DuctedKeeps 103% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 103% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.12 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.1 (HSPF2)
- Great
- 3LEA09SZ26-Owith ducted air handler LEA09DUCT-INOVAIR1 ton · 9,000 Btu/h · DuctedKeeps 86% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 86% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.25 (COP at 5°F)
- Great
- Seasonal efficiency
- 11.0 (HSPF2)
- Top 10%
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view