Skip to content

AIRTEMP vs DIRECT AIR: heat pump ratings compared

Against heat pumps of the same size and type, a typical AIRTEMP model beats 36% and a typical DIRECT AIR model 67%. DIRECT AIR rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

AIRTEMP

36%

of similar heat pumps beaten by its typical model

Well below average

47 models listed

DIRECT AIR

67%

of similar heat pumps beaten by its typical model

Well above average

47 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FAIRTEMP: Beats 25%DIRECT AIR: Beats 62%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FAIRTEMP: Beats 37%DIRECT AIR: Beats 64%
  • Winter-long heating efficiencyHSPF2AIRTEMP: Beats 30%DIRECT AIR: Beats 76%
  • Summer-long cooling efficiencySEER2AIRTEMP: Beats 35%DIRECT AIR: Beats 71%
  • Hot-day cooling efficiencyEER2AIRTEMP: Beats 48%DIRECT AIR: Beats 62%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    AIRTEMP
    43%
    DIRECT AIR
    94%
  • Xcel CC

    AIRTEMP
    40%
    DIRECT AIR
    85%
  • CEE Advanced

    AIRTEMP
    4%
    DIRECT AIR
    2%
  • ENERGY STAR CC

    AIRTEMP
    26%
    DIRECT AIR
    87%

All-around best, ductless 3.5–4.5 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

AIRTEMP

  1. 1DXH42FMK3IHAIRTEMP3.5 tons · 42,000 Btu/h · DuctlessCold-climate pick, score 66.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    90% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Below the middle
    Cooling efficiency
    21.0 (SEER2)
    Below the middle
    Hot-day cooling
    13.0 (EER2)
    Top 10%
    67.7score / 100Heating 67 · Cooling 69

DIRECT AIR

  1. 1DIRM4-48HXPRO28-5ZDIRECT AIRAlso listed as DIRM4-48HXPRO28-6Z4 tons · 47,000 Btu/h · DuctlessCold-climate pick, score 73.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    96% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    23.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Good
    75.6score / 100Heating 72 · Cooling 79
  2. 2DIRM4-48DA25-5ZDIRECT AIRAlso listed as DIRM4-48DA25-6Z4 tons · 46,000 Btu/h · DuctlessCold-climate pick, score 56.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    78% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.05 (COP at 5°F)
    Good
    Winter efficiency
    10.5 (HSPF2)
    Good
    Cooling efficiency
    22.2 (SEER2)
    Great
    Hot-day cooling
    12.3 (EER2)
    Great
    68.6score / 100Heating 56 · Cooling 81
  3. 3DIRM4-60HXPRO28-6ZDIRECT AIR4.5 tons · 51,000 Btu/h · DuctlessCold-climate pick, score 66.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    85% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.5 (HSPF2)
    Good
    Cooling efficiency
    22.2 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Good
    63.6score / 100Heating 53 · Cooling 74

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view