Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
AIRTEMP vs iCongo: heat pump ratings compared
Against heat pumps of the same size and type, a typical AIRTEMP model beats 36% and a typical iCongo model 42%. iCongo rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
AIRTEMP
36%
of similar heat pumps beaten by its typical model
Well below average47 models listed
iCongo
42%
of similar heat pumps beaten by its typical model
Below average47 models listed
- Efficiency on a 5°F dayCOP at 5°FAIRTEMP: Beats 25%iCongo: Beats 37%
- Heating power kept at 5°FCapacity at 5°F vs 47°FAIRTEMP: Beats 37%iCongo: Beats 52%
- Winter-long heating efficiencyHSPF2AIRTEMP: Beats 30%iCongo: Beats 49%
- Summer-long cooling efficiencySEER2AIRTEMP: Beats 35%iCongo: Beats 48%
- Hot-day cooling efficiencyEER2AIRTEMP: Beats 48%iCongo: Beats 28%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- AIRTEMP
- 43%
- iCongo
- 32%
Xcel CC
- AIRTEMP
- 40%
- iCongo
- 32%
CEE Advanced
- AIRTEMP
- 4%
- iCongo
- 0%
ENERGY STAR CC
- AIRTEMP
- 26%
- iCongo
- 0%
All-around best, ductless 2 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ductless, 2 tons (21,000–26,999 Btu/h cooling). What size is my system?
AIRTEMP
- 1DXH24PSK3IHwith ductless indoor unit DHH24PUK3IHAIRTEMP2 tons · 22,000 Btu/h · DuctlessCold-climate pick, score 50.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 79% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 26.0 (SEER2)
- Top 10%
- Hot-day cooling
- 13.7 (EER2)
- Top 10%
- 2DXH24FMK3IHAIRTEMP2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 67.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 21.0 (SEER2)
- Below the middle
- Hot-day cooling
- 13.3 (EER2)
- Great
- 3DXH24ESK3ILwith ductless indoor unit DHH24ESK3ILAIRTEMP2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 13.1Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.75 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 19.0 (SEER2)
- Below the middle
- Hot-day cooling
- 11.9 (EER2)
- Below the middle
iCongo
No ductless, 2 tons model from iCongo.
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view