AIRTEMP vs MOOVAIR: heat pump ratings compared

Against heat pumps of the same size and type, a typical AIRTEMP model beats 36% and a typical MOOVAIR model 68%. MOOVAIR rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

AIRTEMP

36%

of similar heat pumps beaten by its typical model

Well below average

47 models listed

MOOVAIR

68%

of similar heat pumps beaten by its typical model

Well above average

48 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FAIRTEMP: Beats 25%MOOVAIR: Beats 58%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FAIRTEMP: Beats 37%MOOVAIR: Beats 68%
  • Winter-long heating efficiencyHSPF2AIRTEMP: Beats 30%MOOVAIR: Beats 80%
  • Summer-long cooling efficiencySEER2AIRTEMP: Beats 35%MOOVAIR: Beats 72%
  • Hot-day cooling efficiencyEER2AIRTEMP: Beats 48%MOOVAIR: Beats 65%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    AIRTEMP
    43%
    MOOVAIR
    92%
  • Xcel CC

    AIRTEMP
    40%
    MOOVAIR
    92%
  • CEE Advanced

    AIRTEMP
    4%
    MOOVAIR
    2%
  • ENERGY STAR CC

    AIRTEMP
    26%
    MOOVAIR
    88%

All-around best, ductless 2.5–3 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

AIRTEMP

  1. 1DXH30FMK3IHAIRTEMP2.5 tons · 28,400 Btu/h · DuctlessCold-climate pick, score 69.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    90% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.07 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    21.0 (SEER2)
    Below the middle
    Hot-day cooling
    13.6 (EER2)
    Top 10%
    70.5score / 100Heating 70 · Cooling 71
  2. 2DXH36FMK3IHAIRTEMP3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 77.2Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    21.0 (SEER2)
    Below the middle
    Hot-day cooling
    12.0 (EER2)
    Good
    64.5score / 100Heating 77 · Cooling 52
  3. 3DXH36ESK3ILwith ductless indoor unit DHH36ESK3ILAIRTEMP3 tons · 33,600 Btu/h · DuctlessCold-climate pick, score 22.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    72% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.5 (HSPF2)
    Below the middle
    Cooling efficiency
    21.0 (SEER2)
    Below the middle
    Hot-day cooling
    12.0 (EER2)
    Good
    37.0score / 100Heating 22 · Cooling 52

MOOVAIR

  1. 1MXHZA3652AV1MOOVAIR3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 78.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.7 (HSPF2)
    Great
    Cooling efficiency
    23.0 (SEER2)
    Great
    Hot-day cooling
    13.0 (EER2)
    Great
    78.3score / 100Heating 76 · Cooling 81
  2. 2MXHZA2742AV1MOOVAIR2.5 tons · 27,000 Btu/h · DuctlessCold-climate pick, score 72.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.5 (HSPF2)
    Great
    Cooling efficiency
    23.0 (SEER2)
    Great
    Hot-day cooling
    12.5 (EER2)
    Great
    74.4score / 100Heating 73 · Cooling 76
  3. 3MXHSA2742AV1MOOVAIR2.5 tons · 27,000 Btu/h · DuctlessCold-climate pick, score 41.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    25.0 (SEER2)
    Top 10%
    Hot-day cooling
    13.0 (EER2)
    Great
    66.3score / 100Heating 41 · Cooling 91

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view