Skip to content

AUFIT vs Pioneer: heat pump ratings compared

Against heat pumps of the same size and type, a typical AUFIT model beats 53% and a typical Pioneer model 47%. AUFIT rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

AUFIT

53%

of similar heat pumps beaten by its typical model

About average

45 models listed

Pioneer

47%

of similar heat pumps beaten by its typical model

About average

46 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FAUFIT: Beats 64%Pioneer: Beats 41%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FAUFIT: Beats 51%Pioneer: Beats 43%
  • Winter-long heating efficiencyHSPF2AUFIT: Beats 52%Pioneer: Beats 56%
  • Summer-long cooling efficiencySEER2AUFIT: Beats 61%Pioneer: Beats 56%
  • Hot-day cooling efficiencyEER2AUFIT: Beats 38%Pioneer: Beats 40%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    AUFIT
    84%
    Pioneer
    74%
  • Xcel CC

    AUFIT
    78%
    Pioneer
    70%
  • CEE Advanced

    AUFIT
    0%
    Pioneer
    0%
  • ENERGY STAR CC

    AUFIT
    51%
    Pioneer
    54%

All-around best, ductless up to 1.5 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

AUFIT

  1. 1ASW-H18E3B2/*R3DI-D2with ductless indoor unit ASW-H18E3B2/*R3DI-D2AUFITAlso listed as ASW-H18E3B2/**R3DI-D21.5 tons · 18,000 Btu/h · DuctlessCold-climate pick, score 79.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    82% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.25 (COP at 5°F)
    Great
    Winter efficiency
    10.5 (HSPF2)
    Great
    Cooling efficiency
    25.0 (SEER2)
    Great
    Hot-day cooling
    14.0 (EER2)
    Great
    82.9score / 100Heating 79 · Cooling 87
  2. 2ASW-H12C5B3/**R3DI-C6with ductless indoor unit ASW-H12C5B3/**R3DI-C6AUFIT1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 64.1Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    76% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    24.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Below the middle
    62.8score / 100Heating 64 · Cooling 62
  3. 3ASW-H12C5B3/*R3DI-C6with ductless indoor unit ASW-H12C5B3/*R3DI-C6AUFIT1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 64.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    76% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    24.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Below the middle
    62.8score / 100Heating 64 · Cooling 62

Pioneer

  1. 1YN009GLSI25RPHwith ductless indoor unit WT009GLSI25HLHPioneer1 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 63.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    106% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.5 (HSPF2)
    Great
    Cooling efficiency
    25.0 (SEER2)
    Great
    Hot-day cooling
    14.5 (EER2)
    Great
    76.2score / 100Heating 64 · Cooling 89
  2. 2YN012GMSI24RPGwith ductless indoor unit FB012GMSILDFHGPioneer1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 76.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    74% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.51 (COP at 5°F)
    Top 10%
    Winter efficiency
    11.0 (HSPF2)
    Great
    Cooling efficiency
    24.6 (SEER2)
    Great
    Hot-day cooling
    12.7 (EER2)
    Good
    75.8score / 100Heating 77 · Cooling 75
  3. 3YN012GLSI25RPHwith ductless indoor unit WT012GLSI25HLHPioneer1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 62.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.5 (HSPF2)
    Great
    Cooling efficiency
    25.0 (SEER2)
    Great
    Hot-day cooling
    14.0 (EER2)
    Great
    74.4score / 100Heating 62 · Cooling 87