Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
AUX vs Innovair: heat pump ratings compared
Against heat pumps of the same size and type, a typical AUX model beats 52% and a typical Innovair model 58%. Innovair rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
AUX
52%
of similar heat pumps beaten by its typical model
About average149 models listed
Innovair
58%
of similar heat pumps beaten by its typical model
Above average126 models listed
- Efficiency on a 5°F dayCOP at 5°FAUX: Beats 62%Innovair: Beats 58%
- Heating power kept at 5°FCapacity at 5°F vs 47°FAUX: Beats 51%Innovair: Beats 60%
- Winter-long heating efficiencyHSPF2AUX: Beats 43%Innovair: Beats 61%
- Summer-long cooling efficiencySEER2AUX: Beats 51%Innovair: Beats 60%
- Hot-day cooling efficiencyEER2AUX: Beats 40%Innovair: Beats 51%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- AUX
- 68%
- Innovair
- 83%
Xcel CC
- AUX
- 63%
- Innovair
- 79%
CEE Advanced
- AUX
- 1%
- Innovair
- 2%
ENERGY STAR CC
- AUX
- 44%
- Innovair
- 69%
Top cold-climate picks, ducted 3.5–4.5 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, 3.5–4.5 tons (39,000–56,999 Btu/h cooling). What size is my system?
AUX
- 1ASUM42HPMULOAUX3.5 tons · 42,000 Btu/h · DuctedKeeps 83% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 83% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
- 2AHU48HPV1BOwith ducted air handler AHU48HPV1BIAUX4 tons · 48,000 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.5 (HSPF2)
- Great
- 3AHU48HPV1AOwith ducted air handler AHU48HPV1AIAUX4 tons · 48,000 Btu/h · DuctedKeeps 84% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 84% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.0 (HSPF2)
- Good
Innovair
- 1MOM48H2BH6AInnovairAlso listed as MOM48H2BH6B4 tons · 47,000 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 11.0 (HSPF2)
- Top 10%
- 2MOM60H2BH6AInnovairAlso listed as MOM60H2BH6B4.5 tons · 53,000 Btu/h · DuctedKeeps 87% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 87% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.7 (HSPF2)
- Top 10%
- 3MOS60H2BH0Awith ducted air handler MDH60H2MHWAInnovair4.5 tons · 55,000 Btu/h · DuctedKeeps 89% of its heat at 5°FMeets Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 89% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.4 (HSPF2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view