Skip to content

B Air vs JIEJIA: heat pump ratings compared

Against heat pumps of the same size and type, a typical B Air model beats 12% and a typical JIEJIA model 22%. JIEJIA rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

B Air

12%

of similar heat pumps beaten by its typical model

Well below average

5 models listed

JIEJIA

22%

of similar heat pumps beaten by its typical model

Well below average

5 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FB Air: Beats 18%JIEJIA: Beats 15%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FB Air: Beats 8%JIEJIA: Beats 26%
  • Winter-long heating efficiencyHSPF2B Air: Beats 25%JIEJIA: Beats 12%
  • Summer-long cooling efficiencySEER2B Air: Beats 6%JIEJIA: Beats 28%
  • Hot-day cooling efficiencyEER2B Air: Beats 9%JIEJIA: Beats 26%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    B Air
    0%
    JIEJIA
    40%
  • Xcel CC

    B Air
    0%
    JIEJIA
    60%
  • CEE Advanced

    B Air
    0%
    JIEJIA
    0%
  • ENERGY STAR CC

    B Air
    0%
    JIEJIA
    0%

All-around best, ductless up to 1.5 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

B Air

  1. 1BAM120HTICXwith ductless indoor unit BAM120HTICXB Air1 ton · 11,500 Btu/h · DuctlessNot a cold-climate pick: keeps 69% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    17.0 (SEER2)
    Below the middle
    Hot-day cooling
    9.5 (EER2)
    Below the middle
    22.1score / 100Heating 36 · Cooling 8
  2. 2BAM181HTICXwith ductless indoor unit BAM181HTICXB Air1.5 tons · 17,000 Btu/h · DuctlessNot a cold-climate pick: keeps 57% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    58% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.5 (HSPF2)
    Below the middle
    Cooling efficiency
    17.0 (SEER2)
    Below the middle
    Hot-day cooling
    9.5 (EER2)
    Below the middle
    9.5score / 100Heating 11 · Cooling 8
  3. 3BAM121HTICXwith ductless indoor unit BAM121HTICXB Air1 ton · 11,500 Btu/h · DuctlessNot a cold-climate pick: keeps 60% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    61% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.75 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.5 (HSPF2)
    Below the middle
    Cooling efficiency
    17.0 (SEER2)
    Below the middle
    Hot-day cooling
    9.5 (EER2)
    Below the middle
    7.9score / 100Heating 8 · Cooling 8

JIEJIA

  1. 1DMLHT1W-12R4CBPH2with ductless indoor unit DMLHT1G-12R4CBPH2JIEJIAAlso listed as DMLHT1W-12R4BBPH21 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 29.6Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.86 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.0 (HSPF2)
    Below the middle
    Cooling efficiency
    22.0 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Below the middle
    40.3score / 100Heating 30 · Cooling 51
  2. 2DMLHT1W-09R4CBPH1with ductless indoor unit DMLHT1G-09R4CBPH1JIEJIA1 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 20.8Meets Xcel CC
    Heat kept at 5°F
    78% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.75 (COP at 5°F)
    Below the middle
    Winter efficiency
    7.5 (HSPF2)
    Below the middle
    Cooling efficiency
    17.0 (SEER2)
    Below the middle
    Hot-day cooling
    10.2 (EER2)
    Below the middle
    16.9score / 100Heating 21 · Cooling 13
  3. 3DMLHT1W-12R4BBPH1with ductless indoor unit DMLHT1G-12R4BBPH1JIEJIA1 ton · 12,000 Btu/h · DuctlessNot a cold-climate pick: keeps 61% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    62% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.70 (COP at 5°F)
    Below the middle
    Winter efficiency
    7.5 (HSPF2)
    Below the middle
    Cooling efficiency
    17.0 (SEER2)
    Below the middle
    Hot-day cooling
    9.8 (EER2)
    Below the middle
    7.4score / 100Heating 4 · Cooling 11

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view